Appendix C - STORMWATER LOCAL DESIGN MANUAL
4.1.2. SCS method.
About this text
- As published by Municode, current through 2026-05-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
In most cases, the soil conservation service (SCS) method must be utilized to size detention ponds with contributing drainage areas greater than one acre and culverts with contributing drainage areas greater than 25 acres. All computations shall be in accordance with section 3.1.5 of the GSMM (Volume 2). Rainfall depths shall be derived from National Oceanic and Atmospheric Administration (NOAA) Atlas14 publication, Volume 9, Version 2, Dalton Station. The following table also provides the rainfall depths for use in Whitfield County engineer:
Design Storm Rainfall Depth 1-Year 24-Hour 3.22� 2-Year 24-Hour 3.72� 5-Year 24-Hour 4.54� 10-Year 24-Hour 5.22� 25-Year 24-Hour 6.16� 50-Year 24-Hour 6.89� 100-Year 24-Hour 7.26�
4.2. Hydraulic Methods.
All hydraulic calculations shall be made in accordance with chapter 4 of the GSMM (Volume 2).
4.3. Channel Protection Design.
Outlets to provide for meeting channel protection criteria shall be designed to meet the standards outlined in section 2.2.4.2 and section 3.3.5 of the GSMM (Volume 2).
5. SPECIAL DISTRICTS
The county engineer may establish special design criteria for select areas based on the findings of watershed assessments, hydrologic and hydraulic reports, and known flooding issues. The designer is encouraged to consult with the county engineer to determine if any special districts exist within Whitfield County.
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.