--- title: Winder Zoning Ordinance, Sec. 3-3. Non-residential design standards collection: local-codes id: local-code:winder/zoning/3-3 cite_as: Winder, Ga., Zoning Ordinance § 3-3 canonical_url: https://georgiacommons.org/code/local/winder/zoning/3-3 md_url: https://georgiacommons.org/code/local/winder/zoning/3-3.md text_url: https://georgiacommons.org/code/local/winder/zoning/3-3/text source_url: https://library.municode.com/ga/winder/codes/code_of_ordinances date: 2026-08-03 status: active jurisdiction: city:winder jurisdiction_name: Winder place_fips: "1383420" corpus_version: local-codes-winder-f6790af2771b publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/winder/zoning/~appendix-a/~article-iii.md previous: https://georgiacommons.org/code/local/winder/zoning/3-2.md next: https://georgiacommons.org/code/local/winder/zoning/3-4.md index: https://georgiacommons.org/code/local/winder.md branch: zoning edition: As published by Municode, current through 2026-08-03 edition_date_kind: current_through source_publisher: Municode version_id: local-code:winder/zoning/3-3@2026-08-03-457d2d4ef1 --- # Winder Zoning Ordinance, Sec. 3-3. Non-residential design standards > As published by Municode, current through 2026-08-03 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Appendix A - COMPREHENSIVE ZONING ORDINANCE / Article III - GENERAL PROVISIONS A. All non-residential buildings shall be subject to the following standards. B. Exterior walls. The following standards apply to all exterior walls. 1. Within the I Industrial district, exterior wall finish materials (excluding windows, doors, awnings, foundations, or architectural details) shall be limited to the following: i. Brick, including full-depth and half-depth masonry brick, but not simulated brick veneers; ii. Stone, including unpainted natural stone, unpainted cast stone having the appearance of natural stone, and unpainted terra cotta; iii. Stucco, including true cement stucco and EIFS; Impact resistant EIFS shall be used from ground level to a height of 4 feet; iv. Painted concrete block v. Wood, including natural wood or cementitious siding; vi. Shingles, including wood or cementitious shakes and shingles; vii. Tilt/architectural pre-cast concrete; viii. Glass; and ix. Decorative architectural metal, a siding with imbedded color or finish. 2. Within all other non-residential districts, exterior wall finish materials (excluding windows, doors, awnings, foundations, or architectural details) are limited to the following: i. Brick, including full-depth and half-depth masonry brick, but not simulated brick veneers; ii. Stone, including unpainted natural stone, unpainted cast stone having the appearance of natural stone, and unpainted terra cotta; iii. Stucco, including true cement stucco and EIFS; Impact resistant EIFS shall be used from ground level to a height of 4 feet; iv. Wood, including natural wood or cementitious siding; v. Shingles, including wood or cementitious shakes and shingles; vi. Glass; and vii. Decorative architectural metal, a siding with imbedded color or finish. 3. Notwithstanding subsection B.2 above, painted concrete block shall be allowed only on the rear of the building in all non-residential districts on exterior walls that are not visible from a public or private right-of-way. 4. Where more than one exterior finish material is used, visually lighter materials must be used above visually heavier materials. 5. Building floors shall be delineated and shall be executed through windows, belt courses, cornice lines, or similar architectural detailing, so as to distinguish each floor. C. Building massing. In any non-residential district except the I Industrial district, facades over 50 feet in length must incorporate wall projections or recesses a minimum of 12 inches in depth. The combined length of said recesses and projections must constitute at least 20% of the total façade length. D. Storefront standards. 1. A vibrant commercial storefront is a Storefront Property, as defined in Section 2-1 in a non-residential based zoning Districts, which meets the following conditions: i. Is found to be engaging in business for at least sixty (60) days during each quarter; and ii. Has an active Occupational Tax Certificate. 2. Ground floor storefronts along a public street, or as required along an open space, must: i. Provide fenestration for at least 65 percent of the exterior facade area, with each facade calculated separately. ii. Provide no more than 20 linear feet without fenestration. iii. Allow views into the building interior for a depth of at least five feet. iv. The transparency of these windows shall not be obstructed, obscured, or diminished by any means, including but not limited to curtains, blinds, signs, banners, decals, or tinting, which reduce the clear view of the interior from the exterior. 3. In the DT and, storefronts must also include: i. A non-glass bulkhead of 12 to 24 inches in height directly above the finished floor; ii. A glass display window directly above the bulkhead and extending to at least ten feet above the finished floor; iii. An awning or canopy installed directly above the storefront window that is at least as wide as the display window.