Skip to content
Georgia Commons
Menu

Winder · Zoning Ordinance

Appendix A - COMPREHENSIVE ZONING ORDINANCE / Article III - GENERAL PROVISIONS

Sec. 3-4. Required open space amenities for residential developments.

About this text

  • As published by Municode, current through 2026-08-03
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

A. All single-family and multifamily residential developments with more than 15 units shall provide open space amenities as specified in this section.

1. For residential developments in a TNPD, or PUD district, these requirements shall apply to the portion of the development that is residential.

2. Residential developments in the DT Downtown district shall be exempt from these requirements.

B. Cottage court developments shall be exempt from these requirements but shall provide a landscaped courtyard of at least 40 feet in width and 3,000 square feet in total area for every 10 units or fraction thereof. No more than 10 dwelling units may face any courtyard.

Portions of the courtyard located in a setback or buffer shall not count toward this requirement. The courtyard shall not be parked or driven on, except for emergency access and permitted temporary events.

C. All open spaces must be designed to be accessible to all residents of the development.

The Zoning Administrator may allow other amenities to count toward these requirements where they are of equal or greater value to those listed below.

D. Open space amenities shall make up at least 20% of the development area.

E. 10% of the open space shall be green space which must remain in its natural state or remain undeveloped.

F. Prior to the issuance of a certificate of occupancy for 50 percent of the units in a development, each development shall provide open space amenities as specified below.

1. Required amenities for single-family developments.

i. 1—14 units: no amenities required.

ii. 15—100 units: one Type 1 amenity or two Type 2 amenities.

iii. 101—150 units: the requirement in 1(ii) above, plus one additional Type 1 amenity or one additional Type 2 amenity.

iv. 151+ units: the requirement in 1(ii) above, plus one additional Type 1 amenity or two additional Type 2 amenities.

2. Required amenities for townhouse and multifamily developments.

i. 1—14 units: one Type 1 amenity or one Type 2 amenity.

ii. 15—100 units: one Type 1 amenity or two Type 2 amenities.

iii. 101—150 units: the requirement in 1(ii) above, plus one additional Type 1 amenity or one additional Type 2 amenity.

iv. 151+ units: the requirement in 1(ii) above, plus one additional Type 1 amenity or two additional Type 2 amenities.

G. Type 1 amenities.

Type 1 Amenity Required Size Swimming pool N/A Clubhouse, meeting facility, or indoor workout facility 1,200 square feet minimum Wading pool. N/A

Splash pool N/A Tennis courts (lighted and enclosed) One court minimum Baseball, softball, football, or soccer field or general athletic field.

Regulation size (if field is for a specific sport) Basketball court Regulation size Pickleball court USA Pickleball regulation size

H. Type 2 amenities.

Type 2 Amenity Required Size Multi-use path minimum 2,500 feet in length, six feet in width Outdoor exercise stations 10 stations minimum Dog park. N/A Community garden 2,000 square feet minimum Community lawn 3,000 square feet minimum Public plaza 3,000 square feet minimum Pocket Park Up to 10,000 square feet Each individual designated natural area minimum 0.5 acres Pond with fishing dock and boat access optional. minimum 1 acres Children's play area minimum 3,000 square feet

Stormwater management facility must be designed by a registered landscape architect or registered civil engineer as a formal or a natural amenity, and may not be fenced or enclosed by walls over 30 inches in height.

N/A

I. Covenants or other legal arrangements must specify ownership of all open space amenities, the method of and responsibility for maintenance, taxes, and insurance, compulsory membership and assessment provisions (where applicable), and must be incorporated into legal instruments sufficient to ensure that the open space requirements of this section are maintained.

J. The following areas shall not count as required open space amenities, unless designed as an amenity as approved by the Zoning Administrator.

1. Required setbacks or buffers.

2. Wetlands, floodplains, or required stream buffers.

3. Utility easements.

4. Slopes in excess of 25%.

5. Stormwater management facility must be designed by a registered landscape architect or registered civil engineer as a formal or a natural amenity, and may not be fenced or enclosed by walls over 30 inches in height.

6. Mail kiosk.

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:winder/zoning/3-4@2026-08-03-dd6c4a7c28

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Winder Zoning Ordinance, Sec. 3-4. Required open space amenities for residential developments | Georgia Commons