(a) Curbs and gutters shall be installed along streets when required for the functional classification of the street. (b) Curbs along collectors and local commercial or industrial streets shall be Portland cement concrete, 8-inch x 24-inch x 14-inch vertical type only, with a minimum strength of 3,000 psi at 28 days. (c) Curbs along residential streets shall be Portland cement concrete, 6-inch x 24-inch x 12-inch vertical type, or 6-inch x 24-inch rolled type, with a minimum strength of 3,000 psi at 28 days. (d) All curbing shall be backfilled. The curb and gutter shall be constructed so as to present a smooth, even line both horizontally and vertically. There shall be no areas of ponding.