All man-made ditches between storm drainpipes and downstream of storm drainpipe shall be designed by a registered professional engineer, landscape architect, or registered land surveyor. The ditch profile and cross-sections shall be shown on the plans as reviewed by the city. The plans shall show the velocity and flow at each cross-section. Stormwater velocity shall not exceed five fps unless the ditches are lined.