--- title: Woodbury Zoning Ordinance, Division I (Appendix A, Article 3). RESTRICTIONS THAT APPLY IN GENERAL collection: local-codes id: local-code:woodbury/zoning/appendix-a-article-3-division-i-division-i cite_as: Woodbury, Ga., Zoning Ordinance, Appendix A, Article 3, Division I canonical_url: https://georgiacommons.org/code/local/woodbury/zoning/appendix-a-article-3-division-i-division-i md_url: https://georgiacommons.org/code/local/woodbury/zoning/appendix-a-article-3-division-i-division-i.md text_url: https://georgiacommons.org/code/local/woodbury/zoning/appendix-a-article-3-division-i-division-i/text source_url: https://library.municode.com/ga/woodbury/codes/code_of_ordinances date: 2022-10-28 status: active jurisdiction: city:woodbury jurisdiction_name: Woodbury place_fips: "1383896" corpus_version: local-codes-woodbury-1476a063c9c3 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/woodbury/zoning/~appendix-a/~article-3/~division-i.md previous: https://georgiacommons.org/code/local/woodbury/zoning/article-3.md next: https://georgiacommons.org/code/local/woodbury/zoning/appendix-a-article-3-division-ii-division-ii.md index: https://georgiacommons.org/code/local/woodbury.md branch: zoning edition: As published by Municode, current through 2022-10-28 edition_date_kind: current_through source_publisher: Municode version_id: local-code:woodbury/zoning/appendix-a-article-3-division-i-division-i@2022-10-28-b47ad15a85 --- # Woodbury Zoning Ordinance, Division I (Appendix A, Article 3). RESTRICTIONS THAT APPLY IN GENERAL > As published by Municode, current through 2022-10-28 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Appendix A - ZONING / Article 3 - RESTRICTIONS ON PARTICULAR USES / Division I - RESTRICTIONS THAT APPLY IN GENERAL Sec. Z3-4. Minimum Performance Standards for Structures and Uses. Every structure shall be designed, arranged, and situated on the site and in relationship to adjacent uses, every use of land or structure will be conducted, and every lot and every structure will be maintained in such a manner that: A. Will not create a nuisance upon the premises; B. Will avoid detrimental or blighting influences upon the neighborhood and surrounding properties; C. Will not, by means of noise, toxic gasses, fumes, vapors, odors, radiation, light, heat, fire exposure, hazard, vibration, or electrical interference, or by other means, interfere with or impair the use or enjoyment of neighboring premises, including fluctuation of line voltage; D. No lighting shall shine directly on or be a nuisance to occupants of adjacent property, nor impair safe movement of vehicles on any street or highway; E. Will not be hazardous to the community due to such things as the danger of fire or explosion even when conducted under adequate safeguards; and F. Will not create unsightly, unsafe, and/or unmaintained areas of land that are either not built upon, landscaped, or left in a natural state. G. Zoning District and use requirements are set forth in Article 2, Use of Land and Structures of this Ordinance. (Ord. of 7-15-2019) Sec. Z3-5. Provision of Public Facilities or Services Specifically Related to Terms of this Ordinance. Any reference in this Ordinance requiring a facility or land use to be located adjacent or within a specific distance to any public facility or service is in no way an assumption by the City of an obligation to construct such a facility or provide such a service which the City would not otherwise construct or provide or to construct such a facility or provide such a service any sooner than when the City would otherwise have done. (Ord. of 7-15-2019) Sec. Z3-6. Standards for Fences and Walls. The following general provisions shall apply to all fences or walls erected, constructed, or installed after the effective date of this Ordinance. A. Permit Required. No fence shall be erected, constructed, or installed without first having been issued a fence permit by the Building Official. No wall exceeding 48 inches in height can be erected, constructed, or installed without first obtaining design approval from the City Engineer and a permit issued by the Building Official. B. Maintenance. All fences, walls, and other barriers shall be maintained in good condition, structurally sound and attractive. C. Orientation. All fences, required or otherwise, shall have their finished face directed toward adjacent or adjoining residential property or streets, where a residential property is adjacent to or across from the subject site. However, the unfinished face may be oriented toward an alley. D. Allowed Materials for Non-Industrial Districts. The following types of fence materials shall be permitted for fences located in non-industrial districts: 1. Wood. 2. Wrought iron or decorative aluminum. 3. Masonry or stucco wall. 4. Chain link (permitted in rear and interior side yards only). 5. Vinyl. E. Allowed Materials for Industrial Districts. The following types of fence materials shall be permitted in industrial districts. 1. Wood. 2. Masonry or stucco wall. 3. Chain link. 4. Barbed or razor wire (allowed only in rear and interior side yards where used above the height of 6 feet). 5. Finished concrete or cinder block walls. 6. Wrought iron. F. Height. The height of any fence shall not exceed 6 feet except in the following cases: 1. Fences not exceeding 8 feet may be erected in a required side or rear yard when located along a lot line or alley which provides a boundary between residential use on one side and business, commercial, industrial, or manufacturing use on the other. 2. Temporary Construction Fences not exceeding eight (8) feet may be erected in any district provided the requirements of Sec. Z3-83, Temporary or Seasonal Uses of this Article are met. 3. There shall be no height restrictions on the erection of open mesh type fences enclosing parks, recreational areas and school sites. 4. No such fence located in a front yard shall exceed a height of 36 inches on a non-industrial zoned parcel. 5. Industrial uses which shall be limited to 10 feet in height. G. Location. 1. Refer to the requirements of individual Zoning Districts for specific wall or fence criteria. 2. The City Council, at its own discretion, may designate certain new streets or portions thereof as suitable for locating fences in front and/or side yards abutting a street provided the following conditions are met: a) All streets designated shall be identified as thoroughfare plan roadways in the Comprehensive Plan. b) Each street segment designation shall be a minimum of 1 mile in length. H. Non-conforming Fences. All fences legally existing on the effective date of this Ordinance that do not conform to the regulations of this Section may remain and be repaired or replaced in kind as a permitted legal non-conforming use pursuant to the non-conformity provisions of Article 1, Adoption, Purpose and Applicability. (Ord. of 7-15-2019) Sec. Z3-7. Standards for Residential Uses. A. Recreation Facilities. 1. Public and quasi-public playgrounds, parks, non-commercial recreation areas, and swimming, tennis or country clubs and their associated buildings may be allowed in a residential district. No buildings, courts, or playing fields for such uses shall be allowed less than 50 feet from any property line or less than one 100 feet from any street right-of-way. 2. For any residential development of 75 or more detached single-family homes, a common recreation area of 125 square feet per unit shall be provided. Such recreation area shall, at a minimum, provide at least three of the following elements: a) Outdoor playground equipment b) Picnic area (Minimum 1 table per 50 units) c) Tennis courts (Minimum 1 court per 100 units) d) Basketball court (Minimum 1 court per 100 units) e) Passive recreation area (Shall include walking paths) f) Swimming pool that shall meet or exceed ANSI/NSPI-1 standards for Class B public schools and shall be sized as follows, based on the number of dwellings in the development: 1. Up to 200 dwellings: Minimum size of 1,800 square feet, 30'x60'. 2. 201 or more dwellings: Minimum size of 2,250 square feet, 30'x75'. 3. For any townhouse, condominium, or multi-family residential development of 50 or more units, a common recreation area of 100 square feet per unit shall be provided. Such recreation area shall, at a minimum, provide at least three of the elements listed under Sub-section 2 above. 4. The proposed amenity area(s) and recreation amenities to be provided for any residential development shall be submitted as part of the site development application for project approval as required under Article 10, Procedures and Permits. 5. Active recreation areas or amenities may not be developed within a Primary Conservation Area as described in the standards for Open Space Districts in Article 6, Master Planned Developments. 6. Any recreation areas and facilities must be completed within two (2) years after approval of the final plat. The developer shall also provide a performance bond in the amount of 125% of the actual cost of construction to guarantee completion of recreation areas and facilities shown at the time of final plat approval. The bond shall be in effect for two (2) years after the approval of the final plat and shall continue to be in effect until 50% of the development/subdivision is completed (whichever is greatest). B. Zero Lot Line Residences. A zero-lot line configuration may be allowed in the RS-7, RD-2, PDR, OSD-2, or MXU Districts provided that: 1. Any wall constructed on the side lot line must be a solid windowless fire-rated wall. If there is an offset of the wall from the lot line of more than 6 inches, the offset must be at least 6 feet. 2. The minimum building separation between the sides of adjacent dwellings shall be at least two times the minimum side yard required for the district. 3. A 5-foot maintenance easement and a maximum eave encroachment of 2 feet within the maintenance easement may be established in the deed restrictions and covenants of the adjoining lot. This will provide ready access to the lot line wall at reasonable periods of the day for normal maintenance. 4. Preliminary subdivision plans submitted to the Planning and Zoning Commission must indicate the proposed location and configuration of dwellings, driveways, and parking locations for each lot. A draft of the proposed encroachment and maintenance easements must be submitted for review. 5. Zero side yards established under these standards must be continuous along the length of the building. There must be either the lot line wall or a solid wall or fence at least 6 feet high along the lot line adjacent to the building between the established setback and the established rear yard. The wall or fence is used in those cases where the building may be offset as allowed under these standards. 6. Side lot line established shall be the same for all units so that no two units shall share a common wall. C. Townhouses. 1. A row of townhouses shall not contain more than 6 dwelling units. 2. Developments consisting of 20 acres or more shall be limited to a maximum of 30 percent of the total units being constructed as townhouses. 3. Townhouses shall not be designed to give the appearance of row houses. Facades of each unit shall be offset a minimum of 18 inches to create the appearance of separate buildings and shall vary in appearance (color, architectural features, and building materials) with no two facades being alike in a single row of buildings. 4. Exterior finished material shall be constructed with a combination of clay masonry brick, natural stone including granite, marble, sandstone, field stone or any other natural stone approved by the Planning and Zoning Commission; manufactured stone including imitation field stone, marble terrazzo, and any other manufactured finish stone approved by the Planning and Zoning Commission; wood, traditional three coat stucco, or fiber-cement planks and panels either lap siding, shingle siding or vertical siding patterns painted or stained. The use of architectural details such as hip returns, operable window shutters, transoms, wrought iron railings, gas lights, brick molding, and multiple exterior finish materials are strongly encouraged. Structures utilizing a single exterior finish material shall not be permitted without written authorization from the Planning and Zoning Commission. End elevations must be consistent with front facades. 5. Townhouses shall either incorporate a flat roof design utilizing a decorative parapet wall or have a minimum 6:12 roof pitch. Architecturally dimensioned roof covering shall be required. Vents and similar objects shall not be visible from the front of the structure. 6. For pitched roofs, the use of gables, dormers, cornices, chimneys and other design features shall be used to enhance the overall appearance of the homes. 7. HVAC units shall not be visible from the right-of-way. 8. All townhouses shall incorporate front covered porches or front covered stoops in their designs. Porches shall be a minimum of 6 feet in depth. Stoops shall be a minimum of 3 feet in depth. 9. Each townhouse shall front on a dedicated public street. Townhouses may only front on a private street in accordance with the City of Woodbury Subdivision Regulations. 10. Townhouse developments shall establish a homeowners or tenants association to manage and maintain all common areas and structural elements as well as ensure that the requirements governing such associations and their developments as provided by this Ordinance are met in full. 11. Driveway standards for townhouses shall conform to the following: a) All driveways shall be separated a minimum of 8 feet from adjacent driveways. The 8-foot area between the driveways shall be sodded. One exception can be made per every eight units to allow a minimum of 4 feet of sodded area between driveways. b) Townhouses are encouraged to utilize rear garages. Front entry garages must employ carriage style doors and shall be designed to be setback equal to or greater than the front door of the primary structure. For developments consisting of 20 acres or greater, no more than 50% of the units shall have front entry garages. D. Two-Family Dwellings. The following standards address allowed building configurations for two-family dwellings: 1. A single building containing two dwelling units totally separated from each other by a common vertical or party firewall (a traditional duplex) is allowed by-right in the RML, RMH, and PDR Districts and by special exception approval in the RD-2 District. 2. A single building containing two dwelling units each located on a separate floor but accessible via a common outer entrance is allowed by-right in the RD-2, RML, RMH, and PDR Districts and by special exception approval in the RD-1 District. E. Multi-Family Development. 1. Entrances Separated. Common residential building entrances shall be physically separated and distinct from commercial or other non-residential building entrances except that apartment buildings may provide an internal connection between residential areas and retail designed primarily to serve those residences. 2. Storage of Refuse. Residential units shall maintain a separate refuse storage container from that used by non-residential uses. It shall be clearly marked for residential use only and use by non-residential tenants is strictly prohibited. 3. Design. Buildings shall be designed using masonry facades on the front, rear, and two end elevations. a) Masonry for the purpose of this Section shall be divided into two types: Primary Materials and Secondary Materials. b) Primary materials shall include fired clay brick or brick face; natural stone including granite, marble, sandstone, field stone or any other natural stone approved by the Planning and Zoning Commission; manufactured stone including imitation field stone, marble terrazzo, and any other manufactured finish stone approved by the Planning and Zoning Commission. c) Secondary materials shall include stucco on lathe, or fiber-cement planks and panels either lap siding, shingle siding or vertical siding patterns painted or stained. d) Primary materials shall be composed of 40% or more of the area for the front and two end elevations. e) Secondary materials shall compose of 60% or less of the area for the front and two end elevations, but the rear elevation may utilize 100% of the secondary material unless visible from the public right-of-way then it shall utilize the percentages for the front and two end elevations. f) Architectural detailing and decorative trim shall be approved by the Planning and Zoning Commission at their discrepancy. g) Condominiums established via the conversion of an existing apartment development are exempt from this provision. 4. Minimum Unit Size, By Type. Table 3-A below Enumerates minimum multi-family unit sizes: Table 3-A: Multi-family Unit Size Criteria Unit Type Minimum Size (Square Feet) Minimum/Maximum Percentages Studio or Efficiency 500 None/30 One Bedroom 700 None/None Two Bedroom 950 None/None Three Bedroom or More 1100 None/33 5. Minimum Average Unit Size. The average square footage of all residential units proposed for a development must be a minimum of 800 square feet. If the project is phased, at no time shall the average square footage for approved phases drop below the minimum. This provision does not apply to apartments above commercial storefronts. 6. Limitation on Three or More Bedroom Units. No more than 10% of all proposed units in a development may be three or more bedroom units. If the project is phased, at no time shall the total percentage of three-bedroom units exceed 10%. 7. Parking. Any multi-family development utilizing individual driveways (typical of townhouse style apartments), rather than grouped parking spaces, shall conform to the following standards: a) Units less than 35 feet in width must utilize shared driveways or rear access alleys. b) All driveways shall be separated a minimum of 15 feet from adjacent driveways and no driveway shall be located within 5 feet of any property line. 8. Impervious Surface. Multi-family developments shall not exceed 40% impervious surface with the maximum building coverage being 25%. Loft-style apartments are not subject to this limitation. 9. Certificates of Occupancy. Multi-family developments will not be issued a Certificate of Occupancy until site inspections by the Planning and Zoning Commission, City Engineer, and City Landscape Architect confirm compliance with the approved site plan. 10. Number of Entrances. Unless a minimum of two entrances are provided from a publicly dedicated street, all units within a multi-family development shall be located within 1,000 feet from the main entrance. This measurement shall be taken along the centerline of the shortest drive providing access to the unit. See also Article 4, Building Standards, Sec. Z4-8, Street Access. 11. Condominiums. a) Condominium developments shall conform to all applicable rules and requirements as established by Georgia Condominium Act. Prior to approval of any condominium development, the applicant shall provide the City with a copy of the Condominium Homeowner Declaration prepared per the Georgia Condominium Act and filed with the Office of the Clerk of Superior Court of Meriwether County. b) Condominiums may be newly developed or may be established with the conversion of an existing building or buildings. Conversion of existing multi-family developments to condominium or townhouse developments shall be exempt from the density requirements of the underlying Zoning District that allows for condominium or townhouse developments provided that there is no new construction of additional units. c) Condominium developments shall establish a homeowners or tenants association to manage and maintain all common areas and structural elements as well as ensure that the requirements governing such associations and their developments as provided by this Ordinance are met in full. F. Landscaped Entrance. Any residential development involving new access from a public street shall provide a landscaped entrance which complies with the standards of the Tree Preservation and Landscape Ordinance. Landscaped entrances shall be maintained by and be the sole responsibility of the developer/owner of the project or homeowner's association. G. See also Division IV and Division V for standards regarding Alternative Residential Accommodations and Special Care Residential Accommodations. (Ord. of 7-15-2019) Sec. Z3-8. Standards for Non-residential Uses. A. Design Requirements. Commercial buildings and structures with frontage on a major arterial road shall, at a minimum, face the front façade and side of the building up to 50 feet toward the rear of the lot in brick or other finishing masonry including natural or cultured stone and stucco. B. Storefront Developments. Development utilizing the store front configuration shall meet the following development requirements: 1. Pedestrian Orientation. Storefront buildings shall meet the requirements for pedestrian orientation in the Lots and Building. 2. Ground Floor Windows. Storefront buildings shall meet the requirements for ground floor window standards in this Article. 3. Marquee. Storefront buildings shall provide a distinct marquee area, located no less than 12 feet above the sidewalk which may provide one sign parallel to each storefront business which meets the requirements for signs in storefront developments in Article 8, Sign Regulations. 4. Exterior Finish. Exterior finish shall be limited to brick, natural or cast stone, terra cotta, architectural ironwork, stucco, or clear or lightly tinted glass. Walls not intended for exposure may include painted concrete block. 5. Architectural Variety. Arcades, porches and balconies, bays, and other rich architectural elements are encouraged. 6. Entrances. Primary ground floor commercial building entrances may be oriented to the street, to plazas, or parks, not to interior blocks or parking lots. Secondary entrances may be from parking lots or the block interior. Residential entrances may be along the front façade or other façade. 7. Garages. Garage doors are not permitted along a primary street frontage and must, for corner lots, be recessed and located along the secondary frontage a minimum of 50 feet from the street corner. 8. Exterior Storage and Display. No exterior storage or display of items is permitted; provided, however, that the exterior display of produce and plants for sale shall be permitted during the hours of operation. 9. Residential Uses. Residential uses in storefront buildings must meet the requirements of Division IV of this Article. C. Ground Floor Window Standards. 1. Purpose. In districts where such standards are applicable, blank walls on the ground levels of buildings shall be limited in order to: a) Provide a pleasant, rich, and diverse pedestrian experience by connecting activities occurring within a structure to adjacent sidewalk areas. b) Encourage continuity of retail and service uses. c) Encourage surveillance opportunities by restricting fortress-like facades at street level. d) Avoid a monotonous pedestrian environment. 2. Required Amounts of Window Area. The windows must be at least 50% of the length and 25% of the ground level wall area. Ground level wall areas include all exterior wall areas up to 9 feet above the finished grade along street frontages. The requirement does not apply to the walls of residential units or parking structures. On corner lots, only one street frontage must meet the above requirements whereas the other frontage must only meet one-half (½) of the standard. 3. Qualifying Window Features. Required window areas must either be windows that allow views into working areas or lobbies, pedestrian entrances, or display windows set into the wall. Display cases attached to the outside wall do not qualify. The bottom of the windows must be no more than 4 feet above the adjacent exterior grade. 4. Variances. a) Public art may be considered for variance to the ground floor window provision. The Woodbury Planning and Zoning Commission shall recommend to the City Council any work of art considered as a variance to this requirement. b) Where such standards are or may be in conflict with the special safety or security needs of the business, the property owner may seek a variance from these provisions. Such special needs may include a bank or other financial institution where large sums of cash or equivalent are stored, a courthouse, post office, or similar use. D. Modular Commercial or Industrial Buildings. Modular commercial buildings shall meet all state requirements for such structures and shall: 1. Have direct access to adequate water, sewer, and electricity in a manner consistent with other commercial development. 2. Meet all requirements for fire safety as determined by the City Fire Marshall. 3. Be placed according to the setbacks, buffer, and other dimensional requirements of the Zoning District in which it is placed. 4. Have a specific time limit placed on their permitted siting which shall be established by the Building Official unless otherwise specified in this Ordinance. 5. Provide an interim landscaping treatment as approved by the City's Landscape Architect. 6. Be clean and in good condition. Such buildings may not contain signs or other extraneous material attached to the side unless specifically approved by the City. Signs shall meet the requirements of the sign requirements of this Ordinance. E. Outdoor Storage. 1. All outdoor storage shall be located to the side or rear of the building, be located inside of all setback lines, and be screened from public streets and residential districts. No required parking spaces, required landscaped area, or any other required site element shall be used for outdoor storage. 2. Gravel is an acceptable surface for outdoor storage areas in industrial districts. 3. Outdoor storage is not allowed in OI-1, OI-2, and CNH Districts. F. Outdoor Retail Sales. Outdoor retail sales shall be allowed in all non-residential zoning districts, with the exception that in the CBS District such sales shall only be allowed by special exception approval. G. Screening of Dumpsters. Trash containers must be covered and be placed on a pad that shall be completely enclosed on all sides and screened from public streets and residential districts as specified in the City's Solid Waste Ordinance and as specified in the City's Tree Preservation and Landscaping Ordinance. ## History (Ord. of 7-15-2019)