--- title: Barrow County Code of Ordinances, Sec. 42-50. Static pile protection collection: local-codes id: local-code:barrow-county/code/42-50 cite_as: Barrow County, Ga., Code of Ordinances § 42-50 canonical_url: https://georgiacommons.org/counties/barrow/code/42-50 md_url: https://georgiacommons.org/counties/barrow/code/42-50.md text_url: https://georgiacommons.org/counties/barrow/code/42-50/text source_url: https://library.municode.com/ga/barrow_county/codes/code_of_ordinances date: 2026-11-23 status: active jurisdiction: county:barrow jurisdiction_name: Barrow County county_fips: "13013" corpus_version: local-codes-barrow-county-4325bd144603 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/barrow/code/~part-ii/~chapter-42/~article-iii.md previous: https://georgiacommons.org/counties/barrow/code/42-49.md next: https://georgiacommons.org/counties/barrow/code/42-51.md index: https://georgiacommons.org/counties/barrow.md branch: code edition: As published by Municode, retrieved 2026-11-23 edition_date_kind: retrieved source_publisher: Municode version_id: local-code:barrow-county/code/42-50@2026-11-23-6d006a3a53 --- # Barrow County Code of Ordinances, Sec. 42-50. Static pile protection > As published by Municode, retrieved 2026-11-23 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 42 - FIRE PREVENTION AND PROTECTION / Article III - RAW WOOD WASTE PROCESSING/RECYCLING STORAGE AND OPERATIONS (a) Interior pile temperatures of piles subject to this ordinance shall be monitored and recorded on a regular basis per the operational plan. Internal pile temperatures must be taken at 2/3 the pile height, 12 to 24 inches from the surface with a probe-type thermometer. Readings shall be made at not greater than 50-foot intervals along the length of the pile. (b) Once windrows exceed 158 F°, the operator must institute reasonable measures to prevent internal temperatures from continuing to rise. (c) Once windrows exceed 170 F°, the windrows must be reduced in size, be rotated, and be monitored daily until temperatures drop below 158 degrees F°. All green waste stockpiles shall be re-mixed as necessary to alleviate any fire due to spontaneous combustion or temperatures above 170 F°. (d) Windrows shall be visually inspected on a weekly basis. Once fires have been detected in any windrows at a site, this visual inspection shall be a minimum daily requirement. Daily inspections shall continue until the threat of fire no longer exists, and the director approves suspension. (e) All temperature and pile-handling records shall be kept on file at the site and be made available for inspection by department personnel. Data shall include date, time, temperature, specific location, and person conducting measurement. ## History (Ord. of 3-28-2017, § 1)