Sec. 34-93. Building standards for structures and buildings authorized adjacent to the future conditions floodplain and areas of localized special flooding.

About this text

  • As published by Municode, current through 2026-09-02
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

(1) Residential buildings. For new construction or substantial improvement of any principal residential building or manufactured home, the elevation of the lowest floor, including basement and access to the building, shall be at least three feet above the base flood elevation or one foot above the future-conditions flood elevation, whichever is higher.

(2) Non-residential buildings. For new construction or substantial improvement of any principal non-residential building, the elevation of the lowest floor, including basement and access to the building, shall be at least one foot above the level of the base flood elevation or at least as high as the future-conditions flood elevation, whichever is higher.

(Ord. of 10-10-2007, § 603) CD34:26.1 Supp. No. 11

Read this code where it is posted (Municode) The source is the county's code as its publisher or its own website posts it. Check it there for later changes.