(a) The open parking area and all areas surrounding any hotel/motel shall be illuminated by lighting fixtures. The illumination for parking areas shall be required to have an average maintained foot-candle intensity of at least 1.0 foot-candle with a minimum allowable intensity of 0.5 foot candle.
CD44:41 Supp. No. 11
(b) Hotels/motels shall be required to maintain a security camera system covering the parking lot and the registration/front desk area. The system shall have a minimum of three outdoor cameras and two indoor cameras, and the hotel/motel operator shall check the cameras weekly to ensure they are working properly. The video footage shall be maintained for at least 30 days. The recorded resolution of video must be a minimum of 4CIF (704 × 480), with a frame rate of at least three fps for parking lots and five fps for the registration/front desk area. The system must have a mechanism to export the video to disk or flash drive for use by police and sheriff's deputies for law enforcement purposes.