(a) Requirements. When required by the building official, two or more copies of specifications, and of drawings drawn to scale with sufficient clarity and detail to indicate the nature and character of the work, shall accompany the permit application. Such drawings and specifications shall contain information, in the form of notes or otherwise, specifying the quality of materials, where quality is essential to conformity with the technical codes. All information, drawings, specifications and accompanying data shall bear the name and signature of the person responsible for the design.

(b) Additional data. The building official may require details, computations, stress diagrams, and other data necessary to describe the construction or installation and the basis of calculations. All drawings, specifications and accompanying data, where the building official requires such data to be prepared by an architect or engineer, shall be affixed with the official seal of the architect or engineer.

(c) Structural and fire resistance integrity. Plans for all buildings shall indicate how required structural and fire resistance integrity will be maintained where there is a penetration of a required fire resistance wall, floor or partition made for electrical, gas, mechanical, plumbing, signal and communication conduits, pipes and systems and will also indicate in sufficient detail how the fire integrity will be maintained where required fire resistance floors intersect the exterior walls.

(d) Site drawings. Drawings shall show the location of the proposed building or structure and of every existing building or structure on the site or lot. The building official may require a boundary line survey prepared by a qualified surveyor.

(e) Hazardous occupancies. The building official may require the following:

(1) General site plan. A general site plan drawn at a legible scale which shall include, but not be limited to, the location of all buildings, exterior storage facilities, permanent access ways, evacuation routes, parking lots, internal roads, chemical loading areas, equipment cleaning areas, storm and sanitary sewer accesses, emergency equipment and adjacent property uses. The exterior storage area must be identified with the hazard classes and the maximum quantity per hazard class of hazardous materials stored.

(2) Building floor plan. The building floor plan drawn to a legible scale which shall include, but not be limited to, all hazardous materials storage facilities within the building and shall indicate rooms, doorways, corridors, exits for rated assemblies with their hourly rating location of liquid tight rooms, and evacuation routes. Each hazardous materials storage facility shall be identified on the plan with the hazard classes and quantity range per hazard class or the hazardous materials stored.

History

The history line the source prints at the end of the section.

(Ord. of 10-13-2009, § 302)