--- title: Brantley County Code of Ordinances, Sec. 42-61. General standards collection: local-codes id: local-code:brantley-county/code/42-61 cite_as: Brantley County, Ga., Code of Ordinances § 42-61 canonical_url: https://georgiacommons.org/counties/brantley/code/42-61 md_url: https://georgiacommons.org/counties/brantley/code/42-61.md text_url: https://georgiacommons.org/counties/brantley/code/42-61/text source_url: https://library.municode.com/ga/brantley_county/codes/code_of_ordinances date: 2025-04-03 status: active jurisdiction: county:brantley jurisdiction_name: Brantley County county_fips: "13025" corpus_version: local-codes-brantley-county-ad761106471c publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/brantley/code/~part-ii/~chapter-42/~article-iii.md previous: https://georgiacommons.org/counties/brantley/code/42-35-to-42-60.md next: https://georgiacommons.org/counties/brantley/code/42-62.md index: https://georgiacommons.org/counties/brantley.md branch: code edition: As published by Municode, current through 2025-04-03 edition_date_kind: current_through source_publisher: Municode version_id: local-code:brantley-county/code/42-61@2025-04-03-cd0cb9c2ee --- # Brantley County Code of Ordinances, Sec. 42-61. General standards > As published by Municode, current through 2025-04-03 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 42 - FLOODS / Article III - PROVISIONS FOR FLOOD HAZARD REDUCTION In all areas of special flood hazard, the following provisions are required: (1) New construction and substantial improvements shall be anchored to prevent flotation, collapse or lateral movement of the structure. (2) Manufactured homes shall be anchored to prevent flotation, collapse, or lateral movement. Methods of anchoring may include, but are not limited to, use of over-thetop or frame ties to ground anchors. This standard shall be in addition to and consistent with applicable state requirements for resisting wind forces. (3) New construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage. (4) New construction or substantial improvements shall be constructed by methods and practices that minimize flood damage. (5) Electrical, heating, ventilation, plumbing, air conditioning equipment, and other service facilities shall be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding. (6) New and replacement water supply systems shall be designed to minimize or eliminate infiltration of floodwaters into the system. (7) New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of floodwaters into the systems and discharges from the systems into floodwaters. (8) On-site waste disposal systems shall be located and constructed to avoid impairment to them or contamination from them during flooding. (9) Any alteration, repair, reconstruction or improvements to a building which is in compliance with the sections of this chapter shall meet the requirements of new construction as contained in this article. (10) Any alteration, repair, reconstruction or improvements to a building which is not in compliance with the sections of this chapter shall be undertaken only if the nonconformity is not furthered, extended or replaced. ## History (Ord. of 9-13-1988, art. 5, § A)