Curbs, inlets, swales, ditches, pipes, etc., shall be engineered and constructed as required to accommodate stormwater run-off quantities. The development engineer shall submit calculations and elevations, which support the proposed improvements to the county road superintendent for his approval. Material requirements for pipe culverts shall be:

(1) Reinforced concrete pipes or high-density polyethylene (HDPE) shall be required for all culverts. The use of HDPE shall require a minimum of one and one-half foot of cover.

(2) No metal culverts shall be allowed.

(3) The minimum diameter for pipe culverts shall be 15 inches.

(4) All material shall conform to the current Georgia Department of Transportation material specifications.

History

The history line the source prints at the end of the section.

(Amend. of 2-23-2006, art. 8)