--- title: Brooks County Code of Ordinances, Sec. 19-30. Fire protection requirements collection: local-codes id: local-code:brooks-county/code/19-30 cite_as: Brooks County, Ga., Code of Ordinances § 19-30 canonical_url: https://georgiacommons.org/counties/brooks/code/19-30 md_url: https://georgiacommons.org/counties/brooks/code/19-30.md text_url: https://georgiacommons.org/counties/brooks/code/19-30/text source_url: https://library.municode.com/ga/brooks_county/codes/code_of_ordinances date: 2022-11-07 status: active jurisdiction: county:brooks jurisdiction_name: Brooks County county_fips: "13027" corpus_version: local-codes-brooks-county-1b5af7bc6a0c publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/brooks/code/~part-ii/~chapter-19/~article-ii.md previous: https://georgiacommons.org/counties/brooks/code/19-29.md next: https://georgiacommons.org/counties/brooks/code/19-31.md index: https://georgiacommons.org/counties/brooks.md branch: code edition: As published by Municode, current through 2022-11-07 edition_date_kind: current_through source_publisher: Municode version_id: local-code:brooks-county/code/19-30@2022-11-07-af8b132a54 --- # Brooks County Code of Ordinances, Sec. 19-30. Fire protection requirements > As published by Municode, current through 2022-11-07 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 19 - FIRE PREVENTION AND PROTECTION / Article II - FIRE PREVENTION AND CONTROL (a) Fire protection and alarm systems. (1) Fire suppression and detection systems will be installed as required by the life safety codes as adopted by the county board of commissioners to include: a. All assembly occupancies of new bars with live entertainment, nightclubs, dance halls, discotheques, and assembly occupancies with festival seating having an occupant load of 100 or more. b. Modifications or additions to existing buildings for the purpose of housing assembly occupancies of bars with live entertainment, dance halls, discotheques, nightclubs, and assembly occupancies with festival seating where occupancy load exceeds 100 persons. (2) All residential structures containing three or more living units to include townhouses that are more than three stories high will require an automatic sprinkler protection system. Party walls on property lines will be firewalls as described in the IBC. Fire separation requirements may be relaxed in sprinkler-protected structures to onehour rating IAW the IBC. (3) All structures including new one- and two-family dwellings with a fire separation distance of less than ten feet will meet fire protection rating requirements of the International Building Code as described in subsection (b)(1) below. (4) There shall be a fire detection system to meet NFPA 72, as applicable, in all new occupancies of the following classifications: sprinkler protected structures, educational, health care, detention, daycare for children, elderly or handicapped, and group care homes. The system shall notify emergency forces when activated. (5) The property owner is responsible for having the fire detection and/or fire protection system inspected and tested in accordance with NFPA 13A. The system shall be inspected annually and a copy of the inspection report will be submitted to the fire inspector's office. (6) All fire detection systems and fire alarm systems installed in Brooks County, Georgia in commercial buildings will require a permit to be issued as follows: a. Application for a permit will be made at the planning and zoning office. b. Applications will be accompanied with a floor plan showing location of all appliances, i.e., control panels, battery backup, smoke detectors, heat detectors, horns, strobes, pull stations and all other system components. All plans will be approved by the fire department before issuance of the perm it c. Applications will be accompanied by copies of certification of the designer, job supervisor and installers. d. Fire suppression and detection systems shall be permitted separately by the county planning and zoning department. Fire suppression systems shall be tested and maintained IAW N.F.P.A. 25, current edition, by a licensed fire protection contractor and a report of inspection or maintenance forwarded to the fire chief of the county fire department. e. Sprinkler and standpipe fire suppression fire department connections shall be equipped with (2) 2�-inch connections supplied by the contractor. Systems should be tested and inspected annually as a minimum. System owners are responsible for the maintenance and upkeep of their systems and for notifying a repair facility of any malfunction. Records shall be maintained on site for each system inspection, test, or maintenance. f. All sprinkler contractors shall notify the fire department prior to performing any type work, repair, test, or maintenance inside the county. All sprinkler contractors shall be licensed by the state to perform any type sprinkler work. All sprinkler plans for new installation or modification to existing systems must be approved by the appropriate authority, either the state fire marshal's office or the county fire department prior to starting work. g. All insurance companies shall notify the fire department prior to performing any test on sprinkler systems in the county. h. Fire suppression systems control rooms will have installed a "Knox box" entry system keyed to the county fire department code. Property owners will be required to purchase "Knox boxes" for each sprinkler control room and fire alarm control room and provide entry keys for each room to be placed in boxes. Knox boxes applications for Knox box purchasing and installation shall be picked up at the county fire department or from the county's code enforcement officer. Installation of Knox system boxes and locks will be the contractor's responsibility prior to completion for new and existing construction. (7) Class I Standpipe systems shall be installed in accordance with International Building Code Section 905 and NFPA 14 in all new hotels, dormitories, or similar occupancies which are three stories or greater in height, or as otherwise required by the authority having jurisdiction. The authority having jurisdiction is the fire chief. (8) If this section of the code in any way conflicts with the provisions in the International Building Code, the Fire Prevention Code, or the Life Safety Code and NFPA requirements the more restrictive shall apply. (b) "Fire separation distance" shall mean the distance measured from the building face or a line vertical from the eave or overhang to the closest interior lot line, to the centerline of a street, alley or public way, or to an imaginary line between two buildings on the same property. The distance shall be measured at right angles from the lot line. (1) The standard fire separation distance will be ten feet for unprotected surfaces or walls with or without penetrations IAW the International Building Code. a. In residential construction, if the FSD is reduced to less than ten feet but ore the five feet, the interior face of the exterior wall of each adjacent structure must be protected for a one-hour fire rating and have no penetrations or the structure must be sprinkled. b. In residential construction, if the FSD is less the five feet then both the interior and exterior faces of the adjacent walls must have a one-hour fire rating with no penetrations or the structure must be sprinkled. Zero feet separation, such as townhouses, will have a two-hour rated firewall as required by the IBC. c. In commercial construction, if the FSD is less than ten feet, a fire suppression system or fire rated construction IAW the IBC will be required. (c) Fire suppression system water supply and maintenance. (1) Fire suppression systems shall be serviced by a minimum six-inch water main and have a fire hydrant within 100 feet of the fire department connection if wall mounted or 50 feet if freestanding. If the suppression system and the fire hydrant are on the same water main then size required for the water main is eight inches. Exception: modified systems or residential systems that use domestic water supplies. (2) Water mains that service fire hydrants will be a minimum of eight inches in diameter. (3) Dead end water mains that exceed 300 feet in length will be a minimum of eight inches in diameter. Dead end water mains that exceed 600 feet in length will be a minimum of ten inches in diameter. Exception: Where plans can be shown for future development that will continue the water main to tie to an existing water main. (4) New water mains installed are required to extend to the farthest lot lines of that phase of development or to the last lot line of the property owned by the developer. If mains terminate 300 feet or less from an existing water main, the developer will be required to connect to the existing water main to loop the system. ## History (Ord. No. 2022-02(2), Art. X, 11-7-2022)