(2) Number of access points. The spacing of access points shall comply with applicable county, state and AASHTO standards.
(3) Internal circulation. On-site vehicle circulation and parking patterns shall be designed so as not to interfere with the flow of traffic on any public road and shall accommodate all anticipated types of site traffic at projected volumes.
(4) Safety. Access points shall be designed to provide for adequate sight distance and appropriate facilities to accommodate acceleration and deceleration of traffic using the site.
(5) Curb space use plan. Details shall be provided for curb space use on public roads along the development site when such areas will be used for parking, parking space access, delivery and loading zones, passenger zones, bus stops, fire zones and/or other official/emergency zones. The curb space use plan shall include a description of existing conditions prior to development, and proposed changes resulting from the development, including a description of any loss or gain in curb space use by the activities intended.
(h) Traffic analysis contents. A TIA shall be based on peak hour traffic and shall contain information addressing the factors listed below.
(1) Project and site description. The analysis shall contain illustrations and narrative that describe the characteristics of the site and adjacent land uses as well as expected development in the impact area that will influence future traffic conditions. A description of the proposed development including but not limited to access plans, staging plans and an indication of land use and intensity, shall be provided.
(2) Impact area. The analysis shall identify the geographic area under study and identify the roadway segments, critical intersections and access points to be analyzed. The study shall include: all road segments, intersections and driveways on or within 150 feet of the site; all collector or arterial roads and road intersections within one-half mile of the site; and all arterial roads and intersections that the proposed development is projected generate five percent or more of the peak hour traffic. If the engineering director determines the proposed project will have regional impacts, they may require the impact area be expanded.
(3) Existing traffic conditions. The analysis shall contain a summary of the data used in the analysis of existing traffic conditions, including:
a. Existing demand, including traffic count and turning movement information, and the source of and date when traffic count information was collected;
b. Roadway characteristics, including the design configuration of existing roadways, existing traffic control measures (speed limits, traffic signals, etc.) and existing driveways and turning movement conflicts in the impact area; and
c. The existing LOS for roadways and intersections without project development traffic using methods documented in the Special Report 209: Highway Capacity Manual, published by the Transportation Research Board, or comparable accepted methods of evaluation. LOS shall be calculated for the weekday a.m. and p.m. peak hours and, in the case of uses generating high levels of weekend traffic, the Saturday or Sunday peak hour may be required as determined by the engineering director.
(4) Traffic assignment. The TIA shall identify projected peak hour traffic volumes for applicable roadway segments, intersections and driveways in the Impact area. Applicable road segments, intersections and driveways and traffic distribution assumptions shall be identified by the engineering director prior to completion of the study. Projected trip generation shall be based on latest data from the ITE or other studies as approved by the engineering director. This section will document all assumptions affecting the direction, volume and mode split of traffic generated by the project.
(5) Analysis. The analysis shall be based on a two and five year projections for projects with localized impacts. For projects with potential regional impacts, a ten and 20 year projections shall be used. The engineering director shall have final authority to determine if a project has local or regionalized impacts. The analysis shall compare existing demand plus projected demand plus proposed demand with planned capacity for the applicable projections.
(6) Mitigation alternatives. In situations where the LOS standards are projected to be exceeded, the analysis shall evaluate each of the following alternatives for achieving the traffic service standards:
a. Identify additional right-of-way and road improvements needed to implement mitigation strategies;
b. Identify suggested phasing of development and transportation improvements where needed to maintain compliance with LOS standards;
c. Identify the anticipated cost of recommended improvements; and
d. For developments impacting constrained facilities, identify access, pedestrian, transit or other improvements required to mitigate the impacts of the proposed development on the constrained facility.
(i) TDA contents. A TDA shall include the information required for a TIA, except as modified by the engineering director. The study area for a TDA shall include all road segments, intersections and driveways on or within 150 feet of the site.
(j) Process for the review and preparation. The following steps provide an outline of the steps to be included in the preparation and review of a traffic analysis:
(1) The applicant shall meet or correspond with the engineering director to determine whether a TIA or TDA needs to be prepared for a proposed development application, and to identify study issues, assumptions, projections and time periods to be analyzed, analysis procedures, available sources of data, past and related studies, report requirements and other topics relevant to study requirements. GDOT shall be contacted and coordinated with, as appropriate, when the proposed development is adjacent to and/or impacts a GDOT right-of-way. The engineering director must approve the scope and impact area of the TIA or TDA prior to submittal.
(2) Following initial completion of a traffic study, the report shall be submitted to the engineering director for distribution to all jurisdictions involved in the construction and maintenance of public roadways serving the development.
(3) Within 30 days, the engineering director shall provide comments to the applicant. The applicant shall be responsible for responding to the comments. A meeting to discuss the contents and findings of the report and the need for additional study may be requested by the applicant. The applicant shall be responsible for submitting a revised draft, and the TIA or TDA shall not be considered final until the engineering director and GDOT, as required, have approved the TIA or TDA.
(4) Within 30 days of the engineering director determining the TIA or TDA is final, the engineering director shall identify which recommendations in the TIA or TDA the applicant will be required to implement. The identified recommendations shall be incorporated into the staff report or staff approval for the applicable application.
(5) In the case of a TIA or TDA showing deficiencies requiring mitigation within the public right-of-way, negotiations based on the conclusions and findings resulting from the TIA or TDA shall be held with appropriate county staff. The subsequent development approval or, at the option of the applicant, a development agreement, shall identify the applicant's and the county's responsibilities for implementing identified mitigation measures.
(k) Findings and mitigation measures. If the proposed development will not meet applicable service level standards, the engineering director shall recommend denial of the application unless the applicant submits a mitigation plan that, in the opinion of the engineering director, addresses the deficiency through one or more of the following actions:
(1) Reduce the size, scale, scope, or density of the development to reduce traffic generation;
(2) Divide the project into phases and with only one phase at a time being authorized until traffic capacity is adequate for the next phase of development;
(3) Dedicate right-of-way for road improvements;
(4) Construct new road improvements;
(5) Expand the capacity of existing roads and/or intersections;
(6) Redesign ingress and egress to the project to reduce traffic conflicts;
(7) Alter the use and type of development to reduce peak hour traffic;
(8) Reduce background (existing) traffic;
(9) Eliminate the potential for additional traffic generation from undeveloped properties in the impact area; or
(10) Integrate non-vehicular design components (e.g., pedestrian and bicycle paths or transit improvements) to reduce trip generation.
(l) Proportionate share responsibility. If the engineering director determines that requiring the applicant to construct or fund 100 percent of the improvement would not be proportionate to the project's impact to applicable transportation infrastructure, the engineering director shall establish a proportionate (fair) share cost, and the applicant shall mitigate the impact by paying the fair share of the cost of the improvement. The applicant will be required to enter into a traffic mitigation agreement in format acceptable to the county.
(m) Appeals. Appeals to the engineering director's decision shall be heard by the building and construction board of appeals.
(n) Validity. TIAs and TDAs shall be valid for one year from the date of approval. The engineering director may require an updated TIA or TDA if development has not commenced within one year, and there has been a significant change in circumstances, e.g., increase in background traffic, improvements to transportation network, change in project scope, etc. If five or more years have elapsed since the TIA or TDA was approved and development has not commenced or phases of the project have not been started, an updated TIA/TDA shall be required subject to the scope established by the engineering director. For multi-phased projects, the engineering director shall determine when and if development has commenced within the five-year period.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-429. Road encroachment permits.
(a) Purpose. This section documents the procedures for issuance of a road encroachment permit to ensure that access to and construction within public right-of-way is done in a safe manner that is consistent with this UDO and other applicable requirements of the County and State.
(b) Applicability. No work or construction activity related to the installation of any new improvements, and/or enlarging/substantially altering any existing improvements within a county right-of-way is permitted until a road encroachment permit is issued in accordance with the provisions of this section.
(c) Initiation. An applicant shall submit an application complying with the provisions of Appendix D to the engineering director. Applications may be initiated by the owner or agent of the property abutting the right-of-way in which the work is proposed.
(d) Review and action. If the application complies with all applicable provisions of this UDO for submittal requirements, the engineering director may approve the application, approve the application subject to conditions, disapprove the application, or request additional documentation in order to make a determination.
(e) Effect of approval. The road encroachment permit shall be valid for six months. If the proposed work is not completed within this timeframe, the engineering director may renew the permit for an additional six months at the request of the applicant if just cause is shown.
(f) Appeals. Appeals to the engineering director's decision shall be heard by the building and construction board of appeals.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-430. Adoption of technical standards.
(a) Applicability. This section applies to a department with administrative duties under the Code, an ordinance, or another law. A department may adopt technical standards or rules to implement, administer, enforce, or comply with the Code, an ordinance, or another law for which the department is responsible.
(b) Posted notices. The applicable department director shall post notice of new or amended standards or rules on the county website used for notice of public meetings and shall record on the notice the date and time that the notice was posted.
(c) Notice by mail. The departments shall email a copy of a notice posted under this UDO to a person if the person makes a written request to the department to be notified. Unless a person requests notice by the United States Postal Service mail, the department will provide notice by e-mail. If a person requests notice by the United States Postal Service mail, the person shall pay a fee established by separate ordinance for the notice.
(d) Notice contents. The notice must include:
(1) The text of the proposed technical standard or rule, indicating changes from the current text, if any, or a statement that the text is available from the department for public inspection or copying, and the manner and cost of obtaining a copy;
(2) A brief explanation of the standard or rule, or a statement that the explanation of the rule is available from the department for public inspection or copying, and the manner and cost of obtaining a copy;
(3) A request for comments on the rule from the public, listing the name, e-mail address, and telephone number of the person to whom comments should be submitted and the last date by which comments may be submitted.
(e) Period for comments. Public comments on a proposed standard or rule must be received not later than the 31st day after the date that public notice of the rule was posted.
(f) Response to comments. Before a technical standard rule is adopted, the department shall prepare:
(1) A list showing the name of each person who filed a written comment on the rule, and, if it can be determined, whether the person was for or against adoption of the rule as proposed;
(2) A summary of written comments received from the public; and
(3) A justification of the adopted rule, and the reasons why the department may disagree with written comments that it received.
(g) Adoption of a technical standard or rule. After the period for public comment has expired, a department may adopt a technical standard or rule as proposed or it may adopt an amended version of a proposed standard or rule.
(h) Notice of adoption. The notice of technical standard or rule adoption shall be signed by the director of the department adopting the rule, posted on the county's website used for public notices, and must include:
(1) A statement that the rule is adopted and the effective date;
(2) The text of the adopted rule, indicating changes, if any, from the text of the rule as originally proposed, or a statement that the text is available from the department for public inspection or copying, and the manner and cost of obtaining a copy;
(3) If the adopted rule is different than the proposed rule, a brief explanation of the reasons for the changes, or a statement that the explanation is available from the department for public inspection or copying, and the manner and cost of obtaining a copy;
(4) A statement of whether written comments were received from the public; and if comments were received, the department's response to the comments, or a statement that a copy of the comments and the department's response to the comments are available from the department for public inspection or copying, and the manner and cost of obtaining a copy; and
(5) A statement that the adopted rule may be appealed to the county administrator in accordance with the procedures set forth in this chapter, and a brief explanation of the appeal procedure.
(i) Failure to adopt a technical standard or rule.If a proposed technical standard or rule is not adopted on or before the 70th day after notice of the proposed rule was posted, the standard or rule may not be adopted until a new notice and comment period is provided.
(Ord. No. 06-2020, § 3, 12-8-2020)
DIVISION 5. DEVELOPMENT APPROVALS BY BUILDING OFFICIAL
Sec. 114-431. Building permits and certificates of occupancy.
No structure shall be constructed, altered, repaired, equipped, used, occupied, located, maintained, removed or demolished except in compliance with chapter 103 of the County Code. Building permits shall be required prior to initiation of applicable structural work. A certificate of occupancy shall be required prior to the habitation or occupancy of a building or structure.
(Ord. No. 06-2020, § 3, 12-8-2020) Secs. 114-432—114-499. Reserved
ARTICLE VII. SUPPLEMENTAL CONDITIONS FOR SPECIFIED USES
This article includes standards associated with specific uses listed in article V of the UDO and other uses requiring special conditions.
DIVISION 1. GENERALLY
Sec. 114-700. Supplemental conditions.
The conditions in this article apply to all applicable uses when authorized in any zoning district unless the conditions are specifically modified through a planned development approval.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-701. Conversion of dwellings.
The conversion of any structure into a dwelling, or the conversion of any dwelling so as to accommodate an increased number of dwelling units or families, shall be permitted only within a zoning district in which a new structure of similar occupancy would be permitted under this UDO, and only when the resulting occupancy will comply with the requirements governing new construction in such zoning district, including, but not limited to, minimum living area, minimum lot size, lot area per dwelling unit, percentage of lot coverage, dimensions of yards and other open spaces, and off-road parking.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-702. Parking and storing of structures.
Unless otherwise authorized in this UDO or the building code, no trailer, mobile home, manufactured home, modular home or any structure being moved shall be parked or stored on a lot for more than 48 hours.
(Ord. No. 06-2020, § 3, 12-8-2020)
DIVISION 2. ACCESSORY BUILDINGS, STRUCTURES, AND USES
Sec. 114-705. Generally.
(a) Except within an A-5 or a RR district, as provided by article V, no accessory building shall be constructed or used upon a lot until construction of the principal building has commenced. Additionally, the following shall apply to all accessory buildings not otherwise permitted per article V:
(1) No accessory building shall be occupied until the principal building is legally occupied.
(2) No accessory use shall be established until the principal use is legally established and operating.
(3) If the principal use is terminated, all uses accessory to that use shall be terminated.
(4) If the principal building is destroyed or damaged to the point that it may not be used, the owner may apply for a temporary use permit to allow continued use of accessory buildings and structures while the principal structure is repaired, but in no case shall the permit be granted for more than two years.
(b) No accessory building shall be in a front yard except that in an A-5, RR-2.5 RR-1.5, or RR-1 district, when the principal structure is set back at least 50 feet from the front road line, a detached garage may be constructed in the front yard under the following conditions:
(1) The detached garage does not encroach into any required setback or easement;
(2) The garage doors do not face the road on which the lot fronts; and
(3) The garage is constructed of the same materials and is designed to appear to be part of or integrated with the principal structure.
(c) With the exception of a farm building or structure used for agricultural purposes in the A-5, RR-2.5, or RR- 1.5 district, no accessory building may exceed the height of the principle building or exceed 50 percent of the principal building's floor area.
(d) In any R or PD district, accessory buildings other than detached garages or authorized guest houses, shall not exceed 15 feet in height or 35 percent of the primary structure floor area or 200 square feet, whichever is greater, in floor area. Said structures shall be in a side or rear yard and must meet side and rear setbacks. Detached garages and authorized guest houses shall comply with district setback and height limitations for principal structures.
(e) Excluding farm buildings and structures used for bona fide agricultural purposes, no more than two accessory buildings may be established in any RR 1.5, RR-1, or R district.
(f) No outdoor storage of goods and materials, structures on a permanent foundation, or refuse containers for multi-family, mixed-use or non-residential development shall be located within any required setback, except for the temporary placement of refuse containers for curbside pick-up.
(g) In an A-5 district, a landing strip for use by one single engine aircraft is allowed as an accessory use.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-706. Accessory dwelling units or guest houses.
An accessory dwelling unit or guest house shall be permitted as an accessory use on any lot on which a detached single-family dwelling unit exists in accordance with the provisions of this section and all applicable codes and regulations, including, but not limited to, building and health codes:
(a) The accessory dwelling unit or guest house must be clearly subordinate to the principal structure and must be of a design and construction allowed in the zoning district and be of a similar design and construction as the principal structure.
(b) The minimum lot size for a lot on which an accessory dwelling unit or guest house is situated shall be no less than one acre, unless the lot is serviced by community water or community sewer, in which case the minimum lot size can be reduced to 30,000 square feet.
(c) The accessory dwelling unit or guest house shall be limited in size to a maximum of 40 percent of the total living area of the principal dwelling. The maximum size of an accessory dwelling unit, however may not exceed 1,200 square feet.
(d) No more than one accessory structure serving either as an accessory dwelling unit or guest house may be located on a lot.
(e) The accessory dwelling unit or guest house must be owned by the owner of the principal structure.
(f) The accessory dwelling unit or guest house must not be served by a driveway separate from the driveway serving the principal structure.
(g) The accessory dwelling unit or guest house must be situated to the rear or side of the principal structure and must meet the minimum setbacks required for the principal structure.
(h) The height of an accessory dwelling unit or guest house cannot extend higher than the principal structure as measured from grade.
(i) The accessory dwelling unit or guest house must be served by and through the same utility lines and meters that serve the principal structure.
(j) All accessory dwelling units or guest houses must be attached to a permanent foundation.
(k) The accessory dwelling unit or guest house shall share the same sewage disposal and water supply systems as the principal dwelling unit.
(l) The single-family dwelling unit must be a conforming use in the zoning district.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-707. Home occupations.
Home occupations include home offices, which are permitted by right and home service businesses and home trade businesses, which require a conditional use permit in some circumstances.
(a) General standards. All home occupations are subject to the following standards:
(1) The home occupation is operated by a resident of the home.
(2) The home occupation shall be clearly incidental to the residential use of a dwelling and must not change the essential residential character of the dwelling. No internal or external alterations inconsistent with the residential use of a dwelling shall be permitted.
(3) The home occupation shall be limited to no more than 25 percent of the gross floor area of the total dwelling.
(4) An accessory structure shall not be used in connection with a home occupation in R-15 or PD zoning districts except as provided in (c)(1) and (d)(1) of this section.
(5) Accessory structures may be used in connection with a home occupation within A-5, RR-2.5, RR-1.5 and RR-1 zoning districts.
(6) No chemical, mechanical, or electrical equipment that is not normally found in residential dwellings may be used for a home occupation, except for office equipment, such as computers, facsimile machines or copiers.
(7) No outdoor display of products shall be visible from a road.
(8) No disturbance or offensive noise, vibration, smoke, dust, odor, heat, glare, traffic hazard, unhealthy or unsightly condition or nuisance shall be created by a home occupation.
(9) All operations and services shall be conducted indoors.
(10) Outside storage of goods or equipment is prohibited.
(11) No signs other than the authorized nameplate sign pursuant to section 114-663 may identify the home occupation.
(12) Visiting clients, where authorized below, are limited to those provided on an appointment basis and services shall not be offered to the general public on a drop-by basis.
(13) Shipping deliveries and pick-ups (excluding U.S. Postal Service) are limited to two per day.
(14) Home occupations shall comply with applicable Fire and Building Code standards.
(15) If the home occupation is a permitted use within a zoning district, an application shall be submitted to the community development director for review and approval pursuant to section 114-423.
(16) If the home occupation requires a conditional use permit, it shall be reviewed by the P&Z commission and forwarded to the board of commissioners for review and approval pursuant to article III, division 4.
(17) On an annual basis at the time of occupational tax renewal(s), the holder of a home occupation permit shall certify to the community development director that there have been no changes in the home occupation as originally permitted.
(18) If the scope or nature of the home occupation changes or if complaints are filed with the community development director, the community development director shall have the option of revoking the home occupation permit if the permit was issued by the Director, or the Director shall refer the revocation to the board of commissioners if the home occupation was approved pursuant to a conditional use permit.
(19) If deemed necessary, the building official shall inspect the premises and report to the appropriate authority to ensure that applicable requirements are met prior to approval.
The building official shall have the right to inspect home occupation sites on an annual basis.
(20) All required state and federal licenses and approvals are obtained and maintained for the duration of the home occupation. If the county determines that the required State or federal license is expired, the county may revoke the home occupation approval.
(b) Home offices. Home offices are subject to the following regulations in addition to the provisions of paragraph (a) of this section.
(1) Home office uses do not involve retail trade, client visits, or non-resident employees, and may include:
a. Professional offices for certified, ordained, licensed or registered professions, including, but not limited to offices for an architect, draftsman, attorney-at-law, conveyancer, financial planner, land planner, surveyor, professional engineer (civil, electrical, mechanical or other), public accountant, minister or similar professions.
b. Studios for artists and artisans where products are not sold to the public on the premises.
c. Telemarketing and internet-based businesses.
d. Telephone answering and message services.
e. Contractors office whose operations are limited to office work (i.e., no workers congregating on the site, no storage of construction equipment, and no storage of construction vehicles).
f. Other home occupations that the community development director finds to have impacts similar to authorized home office uses.
(2) Only residents of a dwelling may be engaged in the home occupation.
(3) No vehicles requiring a commercial license may be used in association with the home office.
(c) Home service businesses. Home service businesses are subject to the following regulations in addition to the provisions of paragraph (a) of this section.
(1) Home service businesses include home occupations that involve specialized equipment, businesses that primarily provide services to visiting clients, and businesses with incidental sales. A conditional use permit is required prior to approval of a home service business in an R or PD district, whether conducted in the principal residence or accessory building.
Home service businesses may include:
a. Personal or medical services offered by individuals licensed by the State, such as licensed massage therapists, physicians, osteopaths, healers, dentists, midwives, barbers and hairstylists.
b. Individuals involved in teaching classes of up to three students at a time.
c. Bakers and caterers with no on-site sales or service.
d. Other home occupations that the community development director finds to have impacts similar to authorized home office uses.
(2) In addition to the resident operator of the home service business, up to three persons may be employed in the business, provided that at least one is a resident of the site.
(3) Retail sales shall be limited to sale of goods that are incidental to the primary service provided.
(4) The number of vehicles parked by clients, patrons, employees or business-related visitors at the site of a home-based business shall be limited to no more than three at any given time.
(5) The applicant for a home service business shall demonstrate how on-site parking for the maximum number of allowed clients will be provided on the site.
(d) Home trade business. Home trade businesses are subject to the following regulations in addition to the provisions of paragraph (a) of this section.
(1) Home-trade businesses include home occupations that involve specialized equipment and businesses that produce goods for sale to clients. A conditional use permit is required prior to approval of a home trade business in an R or PD district, whether conducted in the principal residence or accessory building. Home trade businesses may include:
a. Individuals producing custom products for individuals, such as furniture or works of art.
b. Growing of houseplants or flowers in a greenhouse no larger than 500 feet of floor area.
c. Artists or artisans with galleries or display areas that do not exceed 200 square feet of floor area.
(2) Sale of products shall be limited to products made on the premises unless otherwise approved by a conditional use permit.
(3) In addition to the resident operator of the home trade business, up to three persons may be employed in the business, provided that at least one is a resident of the site.
(4) The number of vehicles parked by clients, patrons, employees or business-related visitors at the site of a home-based business shall be limited to no more than three at any given time.
(5) The applicant for a home trade business shall demonstrate how on-site parking for the maximum number of allowed clients will be provided on the site.
(e) Unsafe home occupations.
(1) If, in the opinion of the building official, any home occupation has become dangerous or unsafe, or presents a safety hazard to the public, pedestrians or motorists, or presents a safety hazard to adjacent or nearby properties, residents or businesses, the building official shall issue an order to the dwelling owner and/or tenant on the property on which the home occupation is being undertaken directing that the home occupation be immediately made safe or be terminated.
(2) The property owner and/or tenant shall be responsible for taking the necessary corrective steps or measures, but in the event of a failure to do so by the owner and/or tenant, after notice and a reasonable period of time, the building official may take any action to make the home occupation and dwelling safe. Costs incurred by the building official, if forced to take enforcement actions, shall be borne by the property owner and, shall be treated as a zoning violation pursuant to this UDO.
(f) Prohibited home occupations. Except as specifically authorized above, the following home occupations are prohibited:
(1) Public or private clubs;
(2) Restaurants;
(3) Stables and kennels;
(4) Automobile repair and paint shops;
(5) Body piercing services;
(6) Hotels or motels;
(7) Palm reading and fortune telling;
(8) Tattoo and body art or body modification studios; and
(9) Any use that would constitute a nuisance as defined by the county's Code of Ordinances.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-708. Family child care learning home.
A family child care learning home, providing day care only to six or fewer non-resident children under the age of 18 that meet all applicable requirements imposed by the State of Georgia is allowed as an accessory use in the A-5, RR, R-15 and PD district subject to the following requirements:
(a) The owner of the dwelling shall reside on the premises.
(b) A family child care learning home shall not be located within 1,000 feet from any other family child care learning home.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-709. Outdoor dining/outdoor seating.
(a) Generally. The commercial use of patios and outdoor dining areas is an accessory use to restaurant uses of all types. Commercial use of patios and outdoor dining areas is limited to service of food and beverages, and may include occasional live entertainment, as provided in this section.
(b) Use of sidewalks. Outdoor dining areas are not allowed within public easements, rights-of-way, or required setback.
(c) Detectable barrier. If a patio or outdoor dining area projects from a building, a detectable barrier, which may be movable, that is at least 36 inches in height shall enclose the patio or outdoor dining area.
Access openings through the barrier shall be at least 44 inches wide.
(d) Furnishings.
(1) Umbrellas may be used to shade tables and if provided, there shall be at least seven feet of clearance.
(2) No cooking utilities, including grills, shall be permitted in the outdoor dining area. Cooking facilities shall be contained within the principal building unless specific written authorization is granted by the county administrator for a special event.
(3) Appropriate waste receptacles with affixed lids shall be provided.
(e) Clear pedestrian passage. Outdoor dining areas that are located next to sidewalks or hard-surfaced trails shall leave not less than five feet of clear sidewalk for pedestrian circulation.
(f) Relationship to abutting businesses. Outdoor dining areas and patios shall not interfere with access or visibility to abutting businesses.
(g) Hours of operation. Commercial use of patios and outdoor dining areas is limited to the hours of:
(1) 7:00 a.m. to 11:00 p.m. if the principal use is located more than 600 feet from a residential zoning district; or
(2) 7:00 a.m. to 10:00 p.m. if the principal use is located 600 feet or less from a residential zoning district.
(3) All distances shall be measured from the nearest property line of the principal use to the nearest zoning district boundary.
(h) Live entertainment. Amplification shall be permitted only in conjunction with a special events permit.
(i) Conditions of approval. The community development director may condition approval of this accessory use upon:
(1) Limiting its extent;
(2) Establishing a certain approved layout, including a maximum number of tables and chairs;
(3) Establishing the range of dates during which the use may operate; and/or
(4) Restricting the piping of music or prohibiting live entertainment.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-710. Outdoor display.
The following regulations apply to all retail, wholesale, and service establishments except authorized open air businesses.
(a) The outdoor display area shall be arranged to provide safe pedestrian and vehicular circulation and safe emergency access. Maneuvering aisles shall be kept free of all obstruction.
(b) The sale or outdoor display of merchandise shall not be permitted within the required setback areas.
(c) Outdoor display areas located on parking lots shall not reduce the available parking spaces to fewer than those required by section 114-618 for the principal use.
(d) No outdoor display area or parking serving an outdoor display area shall be located within 50 feet of any RR, R or PD district boundary line or road.
(e) The display of soil, sand, mulch, and similar loosely packaged materials shall be contained and covered to prevent it from blowing onto adjacent properties. The outdoor display of fertilizers, pesticides, and other hazardous materials, unless packaged in approved containers, is prohibited.
(f) All outdoor display and sales areas shall be paved with a permanent, durable, and dustless surface and shall be graded and drained to dispose of all surface water.
(g) All loading and truck maneuvering shall be accommodated on-site. Maneuvering in the public right-of-way is prohibited.
(h) Lighting for security purposes may be required, as determined by the community development director. All lighting shall be shielded from adjacent RR, R and PD districts and uses.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-711. Outdoor storage.
(a) Except as permitted by this UDO in certain zoning districts, the storing of junk or parking of an inoperable motor vehicle is prohibited.
(b) Outdoor storage shall not be permitted in any front yard.
(c) No articles, goods, materials fixed machinery or equipment, vehicles, trash, animals or similar items shall be stored, kept in the open or exposed to view from adjacent sites, roads or sidewalks.
(d) In B-2, C-I and P/I districts, outdoor storage areas shall be fully enclosed by a brick, masonry, wooden or solid face fence or wall not less than six feet and not more than eight feet in height. The decorative side of the fence shall face outward.
(e) In I districts, outside storage and operations shall be screened by a combination of solid fences or walls made of wood, brick, or masonry, berms and plantings. The screen must be of such height that all outside storage is screened from public view. No sheet metal fence shall be allowed.
(f) The community development director may permit the required screening to be comprised of plant material, upon a determination that the alternate materials will provide the same degree or better of opacity, screening and compatibility with adjoining properties as a fence or wall.
(g) Storage abutting properties zoned for residential use shall provide a 50 foot buffer between the fence and the property line. Buffer shall meet the standards identified in section 114-630.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-712. Reserved.
Sec. 114-713. Storage or parking of vehicles and major recreational equipment and commercial vehicles.
(a) Major recreational equipment.
(1) For purposes of this section, "major recreational equipment" is defined as including boats and boat trailers, travel trailers, pickup campers or coaches (designed to be mounted on automotive vehicles), motorized dwellings, motor coaches, tent trailers, and cases or boxes used for transporting recreational equipment, whether occupied by such equipment or not.
(2) Major recreational equipment may not be stored in front of the principal structure in the RR-1 and R-15 districts. Major recreational equipment must be stored either in an enclosed structure or on the side or rear of the lot and screened from street view. For purposes of this paragraph, storing shall be defined as parking major recreational equipment for more than seven consecutive days where the equipment is in front of the principal structure.
(3) Major recreational equipment may not be parked on public right-of-way for longer than 24 hours. Storage of boats and recreational vehicles in public rights-of-way is prohibited.
(4) Major recreational equipment shall not be used for living, sleeping, or housekeeping purposes, except when parked in a campground, park or other facility approved for such uses.
(b) Commercial vehicles.
(1) Commercial highway tractors or trailers, wreckers, earth moving equipment, logging trucks or trailers, farm tractors, dump trucks or any commercial vehicle with greater than 26,001 gross vehicle weight rating (GVWR) are prohibited from being parked, stored or maintained in the R zoning districts.
(2) Commercial highway tractors or trailers, wreckers, earth moving equipment, logging trucks or trailers, farm tractors, dump trucks or any commercial vehicle with greater than 26,001 gross vehicle weight rating (GVWR) are prohibited from being parked, stored or maintained in RR-1 zoning districts, except where the lot on which such vehicle is parked, stored or maintained is at least one and one-half acres in size.
(3) In the R-MH zoning districts, parking of commercial vehicles with greater than a 26,000 GVWR are subject to the approval of the property owner, homeowners association, or manufactured housing park's management. If parking is permitted, the commercial vehicle must be located in a designated parking space and may not impede ingress or egress.
(4) For purposes of this paragraph (b), storage is defined as parked for longer than 24 consecutive hours.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-714. Accessory bars.
Bars shall be allowed as accessory uses to a hotel, restaurant, private club, or fraternal organization, provided the following standards are met:
(a) Generally. Accessory bars shall comply with applicable rules and regulations established in chapter 4, Alcoholic Beverages, of the Bryan County Code.
(b) Size. The total floor area of all bars shall not exceed 30 percent of the ground floor area up to a maximum area of 600 square feet of the hotel or restaurant.
(c) External entrance. The bar shall not have a separate external entrance other than emergency exits required by this code.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-715. Accessory uses for institutions not located in P/I districts.
(a) When an educational institution is located outside a P/I district, low impact accessory uses shall be permitted by right subject to applicable standards of this UDO.
(b) Low impact accessory uses include auditoriums, gymnasiums, pavilions, picnic areas, unlighted sports fields and sports courts, and other uses that the community development director determines are customary accessory uses that will not be incompatible with adjacent land uses.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-716—114-719. Reserved.
DIVISION 3. SPECIFIC USE STANDARDS
Sec. 114-720. Adult uses.
(a) Adult bookstores, adult entertainment establishments and adult theaters may be permitted in the B-2 zoning district after finding that the following location requirements have been met. Adult uses may not be located:
(1) Within 1,500 feet of the property line of a residential dwelling;
(2) Within 500 feet of the property line of any public library;
(3) Within 600 feet from the property line of any church, shrine, chapel or mortuary, or other place used for religious services;
(4) Within 1,000 feet of the property line of any school or college campus. The schools and colleges referred to herein shall include only such public, private or church-supported schools as teach the subjects commonly taught in the common schools and colleges of this State and shall not include private schools or colleges wherein only specialized subjects such as law, business, music, art, vocational occupational, and other special subjects are taught;
(5) Within 1,000 feet of any other adult use; or
(6) Within 500 feet of any intersection with an average daily traffic count of 15,000 vehicles or greater.
(b) The distance restrictions set out above shall apply in any and all directions from the property lines of the proposed adult use, as measured in a straight line. This distance shall be verified by a plat prepared by a surveyor and furnished by the applicant. This plat shall accompany and be made a part of the application under this section.
(c) Any adult use existing prior to November 7, 1995, shall be considered a non-conforming use. Such non-conforming use shall be subject to the requirements of article XII of this UDO.
(d) Nothing contained herein shall be construed to authorize or legalize the selling, lending, renting, leasing, giving, advertising, publishing or other dissemination to any person or persons, of any book, magazine, movie film, still picture or any other written material, pornographic matter, novelty, device or related sundry item which is obscene material under the laws of the State of Georgia.
(e) Nothing contained herein shall be construed to authorize or legalize any act of prostitution, or distribution of obscene materials, as those acts are defined under federal, state or county laws.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-721. Animal boarding, animal shelters (private), veterinary hospitals and animal services.
Animal boarding, animal shelters (private), veterinary hospitals, and animal services shall be subject to the following requirements in addition to other applicable district standards:
(a) Minimum buffer requirement for all animal boarding facilities and animal shelters (private) will be 30 feet on all sides as established in section 114-630.
(b) Minimum lot size for animal boarding and animal shelters (private) shall be two acres.
(c) No dog runs or animal exercise areas shall be located in a front yard or in any required rear or side setback.
(d) Outdoor runs/exercise areas shall be set back a minimum of 75 feet from all property lines or the required setback for the zoning district, whichever is greater; provided, a 200-foot setback shall be maintained from any residential dwelling.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-722. Automobile repair, heavy.
The following regulations shall apply to all businesses providing heavy repair services for automobiles and light trucks:
(a) All main and accessory structures shall be set back a minimum of 75 feet from any RR, R, or PD district.
(b) There shall be a minimum lot frontage of 100 feet on an arterial or collector street; and all access to the property shall be from that street.
(c) A raised curb of six inches in height shall be constructed along the perimeter of all paved and landscaped areas.
(d) Overhead doors shall not face a public road or RR, R, or PD district. The community development director may modify this requirement upon a determination that there is no reasonable alternative, and the visual impact will be diminished through use of building materials, architectural features and landscaping.
(e) Where applicable, vehicle queuing space shall be provided in front of each service bay for at least two vehicles.
(f) All maintenance and repair work shall be conducted completely within an enclosed building.
Equipment, including hydraulic hoists, pits, and lubrication, greasing, and other automobile repairing equipment shall be located entirely within an enclosed building.
(g) There shall be no outdoor display of vehicle components and parts, such as tires and lubricants, materials, commodities for sale, supplies or equipment.
(h) Storage of wrecked, partially dismantled, or other derelict vehicles, or overnight parking of any vehicle, except a tow truck, shall be permitted in a designated area for up to 30 days. Such area shall be screened from public view in accordance with the screening requirements of section 114-632.
(i) If the use includes vehicle painting, all applicable State and federal requirements shall be met.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-723. Automobile repair, light.
The following regulations shall apply to all businesses providing light repair services for automobiles and light trucks:
(a) A building or structure shall be located at least 50 feet from any side or rear lot line abutting a RR, R, or PD district.
(b) Equipment, including hydraulic hoists, pits, and lubrication, greasing, and other automobile repairing equipment shall be located entirely within an enclosed building. Outdoor storage or display of merchandise, such as tires, lubricants and other accessory equipment is not permitted.
(c) All activities shall occur inside a building. No vehicle may be stored on the property for more than 48 hours.
(d) Storage of gasoline, liquefied petroleum gas, oil or other flammable liquids or gas above ground shall not be permitted.
(e) There shall be a minimum lot frontage of 75 feet on an arterial or collector road.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-724. Bars and nightclubs.
Stand-alone bars or drinking places require a conditional use permit and shall comply with the following standards:
(a) Generally. Bars and nightclubs shall comply with applicable rules and regulations established in chapter 4, Alcoholic Beverages, of the Bryan County Code.
(b) Graffiti removal. The owner or operator of the bar shall remove all graffiti from the walls, fences, pavement, buildings, or other structures associated with the bar within 48 hours of discovery of its appearance on the property.
(c) Litter control. Each day, the owner or operator of the bar shall collect all litter and trash originating from the bar and deposited on the site of the bar and public property within 200 feet of any boundary of the property upon which the bar is located. For failure to maintain a litter-free environment, the owner or operator may be required to locate permanent, nonflammable trash receptacles, 60 gallons or less in size, at convenient locations, appropriately screened from view from the street, outside the use and in the use's parking area. The owner or operator of the bar shall remove all trash from these receptacles on a daily basis, or more frequently if needed to maintain a litter-free environment, and from the sidewalk and public right-of-way adjacent to the property upon which the bar is located.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-725. Bed and Breakfast Establishments.
(a) Types of bed and breakfast establishments.
(1) Bed and breakfast home: A private home of not more than four guest rooms that offers bed and breakfast accommodations.
(2) Bed and breakfast inn: A private home of more than four but not more than ten guest rooms that offers bed and breakfast accommodations.
(b) Performance standards. The following standards shall apply to bed and breakfast homes and bed and breakfast inns:
(1) A bed and breakfast home or in shall be the permanent residence of the owner or manager of the business.
(2) A bed and breakfast establishment shall be permitted only in a residential structure with a minimum gross living area of 3,000 square feet for bed and breakfast home and 4,000 for a bed and breakfast inn.
(3) In any zoning district where these uses are allowed, the establishment must be located on a lot with a minimum area of one acre for a bed and breakfast home and two and one-half acres for a bed and breakfast inn.
(4) Food service shall be limited to the breakfast meal for a Bed and Breakfast Home, and shall be available only to guests and not to the general public. For a bed and breakfast inn, food service may include breakfast, lunch and dinner, but shall only be available to guests
(5) The price of breakfast shall be included in the room rate for bed and breakfast homes and inns.
(6) Signage shall be limited to a nameplate not to exceed two square feet.
(7) In both types of establishments, a maximum of one permitted guestroom may be located in an existing detached structure on the same property provided the additional guestroom does not exceed the maximum number rooms permitted.
(8) To avoid a concentration of bed and breakfast establishments in any RR, R or PD district, no new bed and breakfast establishment shall be located within 1,320 feet of another pre-existing bed and breakfast establishment, measured along a straight line from property line to property line.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-726. Brewpubs, micro-breweries, micro-distilleries and tap rooms.
Brewpubs, microbreweries, micro-distilleries, and tap rooms are allowed in the B-1 district with a conditional use permit and allowed in the B-2 district subject to compliance with State rules and regulations, approval by the public health department, if applicable and the following regulations:
(a) Tap rooms and tasting rooms shall comply with the requirements for accessory bars in section 114-714.
(b) The establishment shall not have a drive-through facility.
(c) Outdoor entertainment shall not be permitted on properties within 1,200 feet of a RR, R or PD district.
(d) All operations shall be conducted within a completely enclosed building, except for an outdoor seating and entertainment area associated with a tap room or food service. An outdoor seating area associated with a tap room or brew pub shall comply with the outdoor dining/seating requirements in section 114-709.
(e) A tap room may offer food to patrons.
(f) At least 51 percent of the malt or brewed beverages offered for consumption or sale at a tap room must be produced on the premises or on real property immediately adjacent to the premises.
(g) No equipment or storage related to the operation of the preparation of malt or brewed beverages (specifically excluding chillers) may be located outside the principal structure.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-727. Campgrounds.
(a) Areas for the temporary location of recreational vehicles, travel trailers, self-propelled campers, tents, and other temporary and movable overnight accommodations may be permitted by conditional use permit in A-5, WB, and DM-1 districts if the following conditions are met:
(1) The proposed site shall contain at least ten acres of area, with at least 5,500 square feet of land for each trailer site and shall provide at least 4,000 square feet of area in each vehicle or trailer space, which shall have at least 40 feet of frontage on a paved access road at least 20 feet in width leading to a public street. Every vehicle or trailer must be parked at least 20 feet from any other vehicle or trailer.
(2) The site shall be served by water supply and waste disposal systems acceptable to the department of public health and/or the county.
(3) A 50 foot wide buffer shall be provided in accordance with section 114-630 between areas used for the parking of trailers and any adjacent commercial or residential uses.
(b) Parking areas for trailers or recreational vehicles permitted under this section may not be used for the location of a trailer for more than 30 days.
(c) The following services shall be provided:
(1) An adequate supply of potable water for drinking and domestic purposes shall be supplied by pipes to all buildings and trailer lots within the campground. Each lot shall be provided with a cold-water tap. Waste from this supply shall be emptied into a drain connected to an approved disposal system.
(2) Toilet and other sanitary facilities shall be provided for males and females and shall either be in separate buildings or shall be separated, if in the same building, by soundproof walls; shall be marked with appropriate signs; and shall have doors at least eight feet apart. Each toilet and each shower stall shall be in a private compartment or stall.
(3) Toilet facilities for males shall consist of not less than one flush toilet, one urinal, one shower with a dressing compartment with at least nine square feet, and one lavatory for every ten spaces or fraction thereof.
(4) Toilet facilities for females shall consist of not less than two flush toilets, one shower with a dressing compartment with at least nine square feet and one lavatory for every ten spaces or fraction thereof.
(5) Suitable laundry facilities shall be provided.
(6) An adequate supply of hot and cold running water shall be provided for each shower, lavatory, and laundry.
(7) Service buildings housing the toilets and sanitary facilities shall be permanent structures complying with all applicable ordinances and statutes regulating buildings, electrical installation, and plumbing and sanitation systems and shall be located not closer than 20 feet nor further than 200 feet from any campground site/space.
(8) All service buildings and the grounds of the campground shall be maintained by the licensee or designated agent and kept free of trash, wastes, standing water or any other condition that would menace the health of any occupant or the public or constitute a nuisance.
(9) Waste from showers, bathtubs, flush toilets, urinals, and lavatories in service and other buildings within the campground shall be discharged into a public sewer system in compliance with applicable ordinances or into a private sewer and disposal plant or septic tank system of such construction and in a manner approved by the department of public health.
(d) Development in campgrounds must meet all other applicable regulations in this UDO.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-728. Check cashing, short term loans, pawn shops and precious metals buyers.
Establishments that offer check-cashing, short-term loans, pawn shops or precious metals buyers, excluding FDIC insured banks or credit unions, are limited to the B-2 district with a conditional use permit and shall meet the following criteria:
(a) The minimum distance between any two short-term loan, check cashing, pawn shop establishments, and businesses that purchase precious metals shall be 2,500 feet, measured in a straight line between the nearest property lines.
(b) All state regulations, particularly with respect to pawn shops and money-lending standards, shall be met.
(c) Short-term loan and check cashing establishments shall post their interest rate and fees for loans clearly near the entrance of the facility.
(d) Pawn shops shall comply with requirements of section 8-19, et. seq of the county Code.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-729. Child and adult day care facilities.
Day care centers, including child care learning centers for more than six children, child care learning centers, and adult day care facilities, but not including family child care learning homes addressed in section 114-708, shall comply with the following requirements:
(a) All state health department regulations for adult or child care centers or kindergartens shall be met, as applicable.
(b) For persons over 18 years of age, there shall be an appropriately enclosed outside recreation area of not less than 30 square feet per person enrolled; for persons 18 years of age or less, there shall be an appropriately enclosed outside recreation area of not less than 75 square feet per person using the recreation area at any one time.
(c) Outdoor recreation areas shall be screened by a privacy fence or wall measuring six feet in height.
(d) If an off-site recreation area is used, there shall be safe pedestrian access between a care center and the recreational area.
(e) As required by the county, the facility shall post applicable traffic control signs notifying drivers of children/adults in the area and install the necessary improvements to ensure safe movement of children in and out of the site.
(f) The minimum area and frontage regulations in Exhibit 729 shall apply in all districts except where the center is a part of a multi-household building or group of buildings or the applicable zoning district requires greater area or frontage.
Exhibit 729: Care Center Area and Frontage Requirements Number of Persons Enrolled Minimum Lot Area (sq. ft.) Minimum Street Frontage (feet) 6 to 10 15,000 100
11 or more 43,560 150
(g) Setbacks for the facility shall comply with the applicable zoning regulations of the district in which the facility is located.
(h) Additional conditions may be imposed pursuant to the site plan review process when applicable.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-730. Drive-through facilities.
Drive-through uses are subject to the following standards:
(a) Traffic queues will not interfere with pedestrian movement along public sidewalks or create a traffic hazard.
(b) Use of the drive-through service will not interfere with the use, enjoyment or operations of adjacent properties.
(c) Drive-through lanes or loading spaces shall not be located any closer than 50 feet to a residential zoning district.
(d) A six foot tall solid faced brick, masonry or wooden wall or fence shall be provided along a property line abutting lots or parcels zoned residential to block lights from vehicles in the stacking lanes or drive-through facility. The community development director may waive this requirement during the site plan review process, if the applicant can demonstrate the site configuration and required buffers will attenuate any light incursion.
(e) Stacking lane requirements.
(1) All uses and facilities providing drive-up or drive-through service shall provide at least the minimum required vehicle stacking spaces established in Exhibit 730.
(2) Stacking spaces shall be a minimum of eight feet wide by 20 feet long.
(3) Stacking spaces shall not impede on-site or off-site traffic movements, including access to parking spaces.
Exhibit 730: Minimum Stacking Space Requirements Activity Minimum Required Stacking Spaces Measured From Restaurant, drive-through 6 Order Box to Beginning of Drive Through Lane Restaurant, drive-through 3 Order Box to Pick-up Window Car wash stall, automatic 6 Stall Entrance Car wash stall, self-service 2 Stall Entrance Gasoline Pump Island 2 Pump Island Other drive-through uses 3 Teller or Window (Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-731. Excavation and mining.
(a) Applicability. Surface mining as defined by O.C.G.A. § 12-4-72(15) shall be subject to review and approval of a conditional use permit pursuant to article III, division 4.
(b) State permit required. Excavation activities that have greater than one acre of disturbed area must obtain a State mining permit. A copy of the approved State mining permit must be submitted to the development services office prior to work commencing.
(c) Construction requirements.
(1) All projects must comply with best management practices as outlined in the "Manual for Soil and Sediment Control in Georgia" as specified in O.C.G.A. § 12-7-6.
(2) Side slopes of any excavated area must be constructed at a 3:1 slope (one foot in elevation change per three feet of horizontal distance) from the top of the excavation to the bottom at all times during construction and at completion of the excavation.
(3) All disturbed areas will have a permanent stand of grass established at completion.
(4) No digging, processing or hauling activities shall take place except between the hours of sunrise and sunset Monday through Saturday.
(5) All wetland impacts must be approved by the USCOE.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-732. Food service, mobile.
All mobile food vehicles providing retail sales of food (food trucks, food trailers or food carts) shall comply with the regulations of this section. These regulations do not apply to "meals on wheels" program vehicles, ice cream trucks or food home delivery services.
(a) Districts where allowed.
(1) Mobile food trucks and trailers for retail sales of food shall be limited to the B-1, B-2, C-I I-1, and I-2 districts.
(2) Mobile food carts for retail sales of food shall be limited to the B-1, B-2, C-I, I-1 and I-2 districts. Food carts shall not be self-propelled or exceed four feet in width by ten feet in length or eight feet in height.
(b) Location criteria.
(1) Food trucks, trailers and carts shall be located a minimum distance of 15 feet from the edge of any driveway, utility box or vaults, handicap ramp, building entrance, exit or emergency access/exit, emergency call box or fire hydrant.
(2) Food trucks, trailers and carts shall not be located within any area of the lot or parcel that impedes, endangers, or interferes with pedestrian or vehicular traffic.
(3) Food trucks, trailers and carts shall not occupy any parking spaces required to fulfill the minimum requirements of the principal use, unless the principal use's hours of operation do not coincide with those of the food truck business. Nor shall any food truck occupy parking spaces that may be leased to another business and used to fulfill its minimum parking requirements.
(4) Food trucks, trailers and carts shall not occupy or limit access to any handicap accessible parking space.
(5) Food trucks, trailers, and carts may not be located in the public right-of-way.
(6) The county administrator must approve mobile food vehicles located on county-owned property, whether the truck, trailer, or cart is associated with a temporary event, special event or an ongoing operation.
(c) Mobile food service operations.
(1) No freestanding signage or audio amplification shall be permitted as part of the mobile food vehicle operations.
(2) No mobile food service operations shall make or cause to be made any unreasonable or excessive noise in violation of county Code.
(3) No mobile food service shall use flashing or moving lights as part of its operation.
(4) Outside of business hours, the vehicle shall not be stored on the site of its operations.
(5) When open for business, the food truck, trailer or cart operator, or his or her designee, must be present at all times, except in cases of an emergency.
(6) The food truck, trailer or cart vendor is responsible for the proper disposal of waste and trash associated with the operation. Vendors shall remove all waste and trash from their approved location at the end of each day or as needed to maintain the health and safety of the public. The vendor shall keep all areas of the permitted lot free and clean of grease, trash, paper, cups, cans or other materials associated with the operation. No liquid waste or grease is to be disposed in tree pits, storm drains or onto the sidewalks, streets, or other public space. Under no circumstances shall grease be released or disposed of in the county's sanitary sewer system.
(7) All equipment required for the operation shall be contained within, attached to or within 20 feet of the food truck, trailer or cart. All food preparation, storage, and salesdistribution shall comply with all applicable county, state and federal health department sanitary regulations.
(d) Authorization.
(1) A mobile food service operation shall be considered a temporary use, and the operator shall obtain a temporary use permit from the county.
(2) The application shall include a sketch showing the footprint of the mobile food vehicle and all related dining or food service appurtenances.
(3) The temporary use application shall include authorization from the property owner for any lot or parcel proposed to accommodate a mobile food vehicle.
(4) Prior to issuance of the temporary use permit, the vendor shall provide evidence of all necessary permits authorizing the preparation and sales of food within the Bryan County, including the department of public health.
(5) If at any time evidence is provided that the lot or parcel is being used other than in compliance with these regulations, the property owner may be cited for violation of this
UDO.
(6) Copies of the temporary use permit and all applicable permits shall be kept in the food truck, trailer or cart at all times.
(7) The county administrator may authorize a temporary use permit for a mobile food vehicle associated with a special event, e.g., neighborhood block party, religious affiliated fair, etc., regardless of zoning district. The special event shall be of limited duration and occur no more than twice a year.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-733. Freestanding cemeteries and columbariums.
In A-5, RR, and B-1, B-2 and C-I districts, cemeteries and columbaria are permitted by conditional use permit and shall meet the following standards:
(a) A survey showing the boundaries of the cemetery and required access is provided by the applicant.
(b) Cemetery plots, columbaria and other structures shall be located a minimum of 50 feet from the property line of any residential use or district and 25 feet from any commercial district.
(c) Driveways and parking areas shall be located a minimum of 20 feet from the property line of any residential use or district and ten feet from any commercial district.
(d) Cemeteries plots, columbaria and other structures on private property shall provide a public access easement from a public road or a private road that allows public access.
(e) Owner/operators shall comply with all State laws, including notification requirements for closing or abandoning cemeteries.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-734. Funeral homes and mortuaries.
Funeral homes and mortuaries shall be subject to the following requirements:
(a) A minimum lot size of two acres shall be required.
(b) An off-street vehicle assembly/staging area shall be provided for funeral processions and activities in addition to the required off-street parking and maneuvering area.
(c) No waiting lines of vehicles shall extend off site or onto adjacent public streets.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-735. Group homes.
This section applies to group homes, including adult congregate living facilities, with six or fewer residents. The intent of the provisions for group homes is to promote residential care opportunities for those individuals that have had difficulty in obtaining adequate housing. It is not the county's intent to suppress that is protected under the Federal Fair Housing Act. The county will make reasonable efforts to accommodate housing pursuant to the Federal Fair Housing Act. Group homes do not include accommodations for pre-release and post-release individuals who have been incarcerated. Prior to receiving approval for this use, the following requirements must be met.
(a) Any applicable state and department of public health regulations for community living arrangements shall be met.
(b) For residents over 18 years of age, there shall be an appropriately enclosed outside recreation area of not less than 30 square feet per resident enrolled; for residents 18 years of age or less, there shall be an appropriately enclosed outside recreation area of not less than 75 square feet per person using the facility at any one time.
(c) The movement of traffic through the street on which the facility is located shall be capable of being controlled to the degree necessary to allow ingress and egress.
(d) The outdoor recreation areas shall be screened by an opaque fence or wall measuring a minimum of six feet in height.
(e) Setbacks for the facility shall comply with the applicable district regulations.
(f) Minimum off-street parking and loading space requirements shall be provided as follows:
(1) A minimum of two parking spaces is required for each group home; plus
(2) One parking space for every six residents, or one for every resident with a car, whichever is greater.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-736. Institutional care facilities and retirement housing services.
This section applies to: (1) Institutional care facilities, which include transitional residential facilities (e.g., shelters, halfway houses, and transitional housing), community residential home, and residential care facilities, as defined and licensed by the State of Georgia; and 2) retirement housing services, which include long term care facilities (e.g., skilled nursing home, independent living facility, personal care home, continuing care retirement community, or assisted living center). Institutional care facilities and retirement housing services are subject to the following regulations and applicable zoning district standards:
(a) Facilities shall meet all requirements of federal, state and other public agencies.
(b) The proposed site shall have direct access to at least one collector or higher function road but shall not be located on a heavily traveled arterial or freeway unless substantial screening is provided along such heavily traveled road. In general, road access must be adequate for the traffic expected to be generated by the proposed development.
(c) The minimum area and frontage regulations in Exhibit 736 shall apply in all districts except where the center is a part of a multi-household building or group of buildings Exhibit 736: Institutional Care Facilities and Retirement Housing Services Area and Frontage Requirements Number of Persons Enrolled Minimum Lot Area (sq.ft.) Minimum Street Frontage (feet) 1 to 10 15,000 150
11 to 25 43,560 200 More than 25 1 acre plus 500 sq. ft. for each resident in excess of 25 400
(d) The design of the facility must be such that no sounds, smells or any other noxious emissions from such activities as kitchens or loading areas will become a nuisance to the community.
(e) Setback, screening, buffering and other requirements shall be established in conjunction with conditional use permit or site plan approval. At a minimum, the buffering, screening, and setback requirements of the zoning district shall be met.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-737. Manufactured housing parks.
In addition to the applicable R-MH district standards, the following standards shall apply in the RMH district:
(a) Incidental sales. The incidental sale of used manufactured homes shall be permitted within the boundaries of a manufactured housing park, subject to the following conditions:
(1) Allowable number. The number of manufactured homes for sale at any one time shall not exceed five percent of the total number of approved manufactured home spaces in any manufactured housing park. However, if there are less than 20 manufactured home spaces, only one manufactured home may be for sale at any one time.
(2) Location. Manufactured homes for sale shall be located only on manufactured housing spaces in the manufactured housing park and subject to the same setbacks and yard requirements as occupied manufactured homes.
(b) Maintenance. There shall be no renovating, overhauling, or repairing to manufactured homes offered for sale within a manufactured housing park. However, customary maintenance shall be permitted, such as would be allowed for an occupant while living in a manufactured home.
(c) Perimeter buffers required. Along all perimeter property lines of a manufactured housing park, the operator shall provide and maintain buffers in accordance with Exhibit 737 and section 114-630. Entrance roads to manufactured housing parks may traverse the required buffers.
Buffer requirements do not apply to roads constructed within a manufactured housing park, except where such roads intersect with a required buffer abutting another road or property line.
Exhibit 737: Minimum Widths of Manufactured Housing Park Buffers Location Minimum Width Width abutting arterial roads 70 feet Width abutting collector roads 50 feet Width abutting all other roads 30 feet Width abutting all property lines other than roads 25 feet
(d) Compliance with subdivision design standards.In addition to complying with the requirements of this article, except as modified herein, all manufactured housing parks must comply with all applicable road and public utility standards.
(e) Minimum dimensional requirements for manufactured housing spaces. The boundaries of all manufactured home spaces must be shown on the manufactured housing park plan and identifiable after construction of the manufactured housing park. Each manufactured home must have a minimum setback of 30 feet on all sides from any other manufactured housing space, except a minimum setback from the right-of-way of any road within the manufactured housing park shall be 25 feet. All manufactured home spaces must meet the minimum size requirements of the public health department, however, in no case shall any manufactured home space be less than 5,280 square feet.
(f) Approval of RMH district. No rezoning to a manufactured housing park district may be considered and no manufactured housing park may be developed, expanded, or occupied until all the requirements set forth herein have been met and a manufactured housing park plan is approved by the board of commissioners. An application and all accompanying plans and supporting data required both by this section and Article III shall be filed with the community development director in accordance with Article III. The manufactured housing park plan must be submitted with a rezoning application. A park plan shall include the following:
(1) Property boundaries;
(2) Access roads;
(3) Interior manufactured home space layout including internal streets;
(4) Required and/or proposed buffers;
(5) Minimum exterior setbacks;
(6) Location of parking spaces;
(7) Lighting plan;
(8) Gross density;
(9) Open space;
(10) Location of trash pickup areas;
(11) Proposed utility connections; and
(12) Amenities.
(g) Public hearings—Park plans. If an existing manufactured housing park seeks to expand and a park plan has not been previously approved, the owner shall submit a park plan in compliance with these standards for the existing park and expansion area and go through the required public hearing process.
(h) Access. All manufactured home spaces must abut an interior road which has direct access to a public road.
(i) Off-road parking. Each manufactured home space shall be provided with at least two off-road parking spaces located on or adjacent to the manufactured home space. In addition, one off-road parking space for each four manufactured home spaces in the manufactured housing park for visitor parking must be provided. Off-road parking spaces shall not be considered a part of any manufactured home space which meets only the minimum required lot area. No vehicle parking will be allowed in other than the specified parking areas.
(j) Additional conditions. In approving a manufactured housing park, the board of commissioners may attach additional conditions to protect both the occupants of the manufactured housing park and the occupants of surrounding property, and to further the purposes of this UDO.
(k) Minimum requirements for manufactured homes. No manufactured home shall be placed in a manufactured housing park unless it is constructed to the Federal Manufactured Home Construction and Safety Standards Act of 1974, as amended, 42 USC §5401 et seq., and is in compliance with the building code.
(l) Water and sewerage. Each manufactured home space shall be provided with and each manufactured home connected to both a central water system and a central sewer system.
(m) Refuse collection facilities. Disposal of solid waste within a manufacture housing park shall be in compliance with all federal, State, and local laws and regulations.
(n) Service, administrative, and other buildings.
(1) Within a manufactured housing park, one manufactured home may be used as an administrative office. Other administrative and service buildings, housing, sanitation, and laundry facilities shall be permanent structures, complying with all applicable ordinances and statutes regarding buildings, electrical installations, and plumbing and sanitation systems.
(2) No building shall be located closer than 30 feet to any manufactured home space.
(o) Fire protection. All manufactured housing parks shall comply with all fire and life safety codes, as adopted by the County. Manufactured housing parks may be inspected by the local fire marshal to ensure compliance.
(p) Management. The owner of a manufactured housing park shall ensure that the manufactured housing park, its facilities, equipment, grounds, roads, buffers, fences, manufactured home spaces and manufactured homes are maintained in a clean, orderly, safe, and sanitary condition and are in compliance with all applicable laws, codes, ordinances and regulations.
(q) Required records. The owner of a manufactured housing park shall maintain the following records relating to the manufactured housing park: the names of all occupants and owners of manufactured homes; the make, model, serial number, year of manufacture, county tax and decal number, and building permit number of each manufactured home and the dates of arrival and departure of each manufactured home.
(r) Occupancy permit. No manufactured home shall be permanently placed within a manufactured housing park until all provisions of this UDO and other applicable laws, codes or regulations have been complied with and a certificate of occupancy is issued by the building official.
(s) Underground utilities. All utilities shall be under ground.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-738. Religious institutions.
Religious institutions, having seating/occupancy for more than 100 people, shall have direct access to a collector or arterial road.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-739. Rural event venue.
The purpose of this use is to address the demand for event venues in a rural setting. For event venues located in the A-5 zoning district, the operation should be consistent with and maintain compatibility with the agricultural/rural setting. A conditional use permit is required in the A-5 zoning district.
(a) All uses and required improvements must be located on the same parcel.
(b) Minimum parcel size is five acres.
(c) An operational plan, which shall be maintained and available on site at all times, must be provided that includes the following information at a minimum:
(1) Parking plan to include traffic control and emergency access.
(2) Life/safety plan.
(3) Capacity of the venue.
(4) Event types.
(5) Anticipated number of events per year.
(6) Maximum number of attendees per event.
(7) Hours and days of operation.
(8) Number of full and part time employees.
(9) Use of music at the facility, including types of sound amplification.
(10) Food and alcohol preparation or services on site.
(11) Provision of restroom facilities.
(12) How solid waste will be disposed of.
(13) Any other documentation required by the Community Development Director.
(d) A concept plan and preliminary architectural elevations are required as part of the Conditional Use Permit application.
(e) At least one permanent building must be located on site. Buildings and structures must maintain rural character.
(f) All buildings and structures must be setback at least 100 feet from property lines.
(g) All temporary structures, e.g., tents, stages, chairs, dance floors, etc., must be a minimum of 100 feet from property line or 150 feet from the nearest adjacent residential structure, whichever is greater.
(h) If temporary outdoor lighting is to be provided, lighting must not spill onto adjacent properties and shall be downward facing.
(i) Property shall have frontage on a County-approved private or public road providing access to the venue. Access drives or private easements shall not be the primary entrance/exit.
(j) A buffer may be required and shall be established through the Conditional Use Permit process.
The need for and size of a buffer shall be determined/based upon the distance to the nearest adjacent residential structure, nature of events (indoor/outdoor), and location of the facilities (temporary and permanent) to the property lines. If required, the buffers must meet the buffer design requirements in article VI, section 114-630 unless otherwise specified.
(k) The non-residential development parking standards (article VI, section 114-616(d)) shall apply, except all parking shall be on site. The number of spaces required shall be determined during the Conditional Use Permit process.
(l) Parking areas may be unpaved. ADA spaces must be provided per section 114-619.
(m) The noise for events shall not exceed 50 dBA at the property line.
(n) An on-site manager shall be present and available for the duration of all events. Their contact information shall be provided and kept up to date with the Community Development Director.
(o) All structures and buildings shall be built to code and approved by a Bryan County building inspector and meet fire codes as well as all other local and state regulations.
(p) Events shall be limited to 7:00 a.m. to 10:00 p.m. weekdays and 7:00 a.m. to 11:00 p.m. weekends unless otherwise specified during the CUP process.
(q) Special events, as defined in this UDO, shall be permitted through the approval process identified in section 114-424.
(r) All signage shall follow the regulations for authorized institutional uses located in the A-5 zoning district in section 114-667, Exhibit 667a. These standards may be altered during the conditional use permit approval if alternative signage is proposed.
(s) Public health department approval shall be obtained, as needed.
(t) Permanent restrooms shall be required to accommodate the expected capacity of the venue.
(u) Overnight lodging, including camping, shall not be permitted unless specifically approved via the CUP process.
(v) Amendments to the approved CUP (major and minor) shall be processed in accordance with section 114-337.
(Ord. No. 16-2021, § 2, 8-10-2021) Sec. 114-740. Self-storage facilities.
(a) All ingress and egress from the site shall be directly onto an arterial or collector street.
(b) Storage of combustible or flammable liquids, combustible fibers, or explosive materials, as defined in the International Fire Code, or toxic materials, shall not be permitted within the self-storage buildings or upon the premises. However, storage of recreational vehicles containing fuel and other automotive fluids is permitted.
(c) The use of the premises shall be limited to storage of personal and business items, except as otherwise provided, and shall not be used for operating any other business, maintaining or repairing vehicles or for any recreational activity or hobby.
(d) Limited retail sales of products and supplies incidental to the principal use, such as packing materials, packing labels, tape, rope, protective covers, locks and chains shall be permitted within a central office.
(e) The entire site shall be fenced, in accordance with the requirements of section 114-632(d). Fences within front yards and any side yards adjacent to residential zoned property shall be wrought iron or a similar decorative type. Chain-link, or similar style fences, are prohibited in these areas.
(f) A security manager may be permitted to reside on the premises. A minimum of two parking spaces shall be provided for the dwelling unit in addition to other required parking.
(g) Minimum separation between self-storage buildings shall be 24 feet.
(h) Internal drive aisles shall be at least 24 feet wide.
(i) Building design and materials shall be comply with the provisions of section 114-806. If located adjacent to a RR or R zoning district, the front office building, or office portion of the building, shall reflect a residential character in architectural design.
(j) Buffering shall comply with the provisions of article VI, division 5.
(Ord. No. 06-2020, § 3, 12-8-2020; Ord. No. 16-2021, § 2, 8-10-2021) Sec. 114-741. Shooting ranges, outdoor.
(a) Purpose. The purpose of this section is to provide standards, a procedure for public review, and to require a conditional use permit for the development of outdoor shooting range facilities to offer recreational firearm shooting opportunities and training activities in a manner that will protect the health, safety, and welfare of the property owners, residents, and other users of land in the vicinity of new shooting ranges.
(b) Applicability. Outdoor shooting ranges may be permitted in A-5 districts by conditional use permit.
(c) Exemptions. This section shall not apply to outdoor shooting ranges developed and operating as of the effective date of this UDO, private outdoor shooting ranges where no fee is charged or membership required for the use of the facility and where firing occurs less than five times per month by other than the property owner or lessee, or to ranges used exclusively for archery; provided, any expansion of a public outdoor shooting range beyond that developed and operating as of the effective date of this UDO, or beyond the terms of a permit issued hereunder, shall require issuance of a new conditional use permit and the total facility shall be subject to the standards of this section.
(d) Definitions. For purposes of this section, the following definitions shall apply:
(1) Backstop means a device constructed to stop or redirect bullets fired on a range.
(2) Baffles means barriers to contain bullets and to reduce, redirect or suppress sound waves. Baffles are placed either overhead, alongside, or at ground level to restrict or interrupt errant or off-the-target shots.
(3) Ballistics means the study of what happens to moving projectiles in the barrel and in flight: their trajectory, force, impact, and penetration. The study is divided into three sections: internal, external and terminal. "Internal" refers to what happens inside the barrel before the bullet or shot leaves the muzzle. "External" is what happens after the bullet or shot leaves the barrel and travels to its final point of impact. "Terminal" is what happens to the bullet or shot at the final point of impact.
(4) Berm means an embankment used for restricting bullets to a given area or as a dividing wall between ranges.
(5) Bullet means a single projectile fired from a firearm.
(6) Bullet trap means a device designed to trap or capture the entire bullet and fragments as opposed to redirecting the projectile into a water or sand pit.
(7) Expansion means any change to a public outdoor shooting range existing as of the effective date of this UDO or any range developed and operating by virtue of a conditional permit, that results in additional firing positions or a lengthened daily period of operations. Expansion shall also include any change increasing the length of the direct fire zone or the area of the shotfall zone in order to accommodate the use of firearms not identified in the then existing conditional use permit application. Modifications made for the purpose of or resulting solely in maintenance or improvement of a facility, such as the installation of sewer, water or other utilities, pavement of a parking lot, the installation of safety baffles, construction of side or backstop berms, or the construction or remodel of a clubhouse, shall not be considered an expansion.
(8) Firearm means a term used to describe any gun, usually small, from which a bullet is propelled by means of hot gasses generated by burning powder (usually smokeless or black powder).
(9) Firing distance means the distance between the firing line and the target line.
(10) Firing line means a line parallel to the targets from where firearms are discharged.
(11) Firing position (point) means an area directly behind the firing line having a specified width and depth that is occupied by a shooter, his or her equipment and, if appropriate, an instructor or coach.
(12) Firing range.
a. Firing range means a facility designed for the purpose of providing a place on which to discharge firearms, shoot air guns, and/or archery equipment.
b. Firing range may refer to several ranges constructed in a complex.
(13) Pistol means a firearm capable of being held, aimed and fired with one hand. Also known as a handgun.
(14) Public shooting range means a firing range where a user fee is charged, or where a person must be a member of a group to be allowed to use the facility and membership requires the payment of dues or fees.
(15) Range manual means The Range Manual - A Guide to Planning and Construction, The National Rifle Association, 1988.
(16) Ricochet catcher means a device installed along a backstop, a berm, or on the range floor, designed to capture ricocheting projectiles. Ricochet catchers are more frequently used on backstop areas where the slope or backstop material does not positively contain bullets.
(17) Rifle means a modern firearm designed to be fired from the shoulder. Its main characteristic is a rifled (grooved) barrel that imparts a spin to a single projectile as it travels through the bore.
a. Some rifles designed for military or law enforcement use may have a pistol grip stock instead of a shoulder stock.
b. For purposes of this chapter, "rifles" shall also include black powder and other muzzle loading firearms, some of which may have rifled barrels.
(18) Safety baffles means vertical or sloping barriers designed to prevent a projectile from traveling into an undesired area or direction. Most often used to prevent bullets from leaving a firing range.
(19) Safety fan applies only to rifle and pistol firing ranges. The safety fan of a firing range consists of three parts: the direct fire zone, the safety zone, and the ricochet zone. The direct fire zone is that area into which all shots are fired during the normal course of shooting. This zone includes all directions and angles of fire used on a firing range while shooting at a specific target, either stationary or moving, from a specific firing point. The length of the direct fire zone extends to the maximum range of the ammunition and firearm used on the firing range but can be shortened by physical barriers or other devices which reduce the maximum distance of a bullet's trajectory. The safety zone extends ten degrees to the left and right of the direct fire zone and protects against errant bullets caused by crossfire or accidental discharge of a firearm. The ricochet zone is that area 45 degrees to the left and right of the firing line and extended a certain distance dependent on the type of firearm and ammunition allowed on the range (i.e., 85 yards for air guns, and up to 1,200 yards for high-powered rifles). The line is then extended parallel to each side of the safety zone downrange to the intersection of a line extended from the terminus of the direct fire zone through the outer corner of the safety zone. See Drawing No. 103 in the Range Manual.
(20) Shotfall zone means that area of a shotgun firing range where spent shotgun shot falls to the earth and where development, other than trap or skeet houses or the equivalent facilities for other types of shotgun events, and human occupancy, other than operators of the trap, skeet or equivalent facilities, is prohibited during active shooting.
(21) Shotgun means a firearm designed to be fired from the shoulder with a smoothbore barrel that fires shot shells possessing a varying number of round pellets;
a. Some barrels are designed to be used with rifled slugs, most generally having smoothbores, but in some cases may be rifled;
b. Law enforcement and military shotguns may have a pistol grip stock instead of a shoulder stock.
(22) Target line means a line parallel to the firing line along which targets are placed.
(e) Development standards. The following standards shall apply to the development of proposed public outdoor shooting ranges upon application for a conditional use permit. The board of commissioners may vary from these standards where the applicant has demonstrated that the proposed facility includes alternative designs and features, either natural or manmade, that will otherwise mitigate the potential adverse impacts to the health, safety and welfare of owners or users of neighboring properties and the general public.
(1) Range design.
a. Pistol and rifle firing ranges. Pistol and rifle firing range design shall include sufficient land area under control of the applicant for a safety fan (direct fire zone, safety zones and ricochet zones) to accommodate the ballistics of the highest powered firearms and ammunition to be used on the range. Such spatial requirements may be reduced in consideration of natural topographic features or manmade improvements, including but not limited to, backstop and side berms, bullet traps, ricochet catchers, and overhead or ground safety baffles which will provide sufficient safety measures to protect adjacent properties.
b. Shotgun ranges. Trap ranges shall have a shotfall zone on property under control of the applicant as established by a line which extends 50 yards to the right and 50 yards to the left of, and perpendicular to, the centerline of the trap house. From each end of said line, boundary lines having interior angles of 130 degrees shall extend down range for 300 yards. Skeet ranges shall have shotfall zones on property under control of the applicant which are a complete semi-circle extending 300 yards from all firing locations.
(2) Security. The entire perimeter of all public outdoor shooting range safety fans and shotfall zones shall be fenced and signed to reduce the potential for trespass into the safety fans and shotfall zones. Warning signs identifying the range shall be posted around the perimeter of the parcel or parcels on which the shooting range is located such that each sign is visible and legible from the next. The same signs shall be posted similarly on the security fencing surrounding the safety fan(s).
(3) Parking. At a minimum, there shall be one and one-half parking places for each firing position.
(4) Noise. All firing line locations shall be located such that the sound levels generated by the discharge of firearms on the range do not exceed a 90 dB peak impulse response at the property line. The burden of proof that the proposed range will meet this standard shall rest with the applicant. All noise studies shall be performed by a professional engineer registered in the State of Georgia or by a person with a degree in a discipline related to acoustics.
(5) Range orientation. All firing lines should be aimed at target lines to the northeast, north or northwest unless there is sufficient standing timber or natural topographic features on the property controlled by the range operator to mitigate the effects of glare from the sun.
(6) Backstops. All backstops shall have sufficient depth of sand or other similar soft earthen material that is free of rocks, stones and other hard objects that may result in bullet ricochets. All manmade berms shall be vegetated to reduce the potential for erosion. A manmade, mechanical backstop may be substituted upon approval of the planning commission. All backstops and berms shall be maintained to perform their intended functions.
(7) Proximity to water bodies. Firing ranges shall be developed such that there are no streams, ponds, lakes, or other watercourses or wetlands located between any firing line and target line or within any shotgun shotfall zone.
(f) Application-Required information. In addition to the general information required by article III, division 4, the following information is required for a conditional use permit application for a public outdoor shooting range:
(1) An assessor's map of the subject property;
(2) The types of firearms, ammunition and shooting to be allowed, such as trap, skeet, muzzle loader, high power rifle, small bore rifle, pistol, action pistol, etc.;
(3) A site plan drawn to scale illustrating the items listed below. The site plan shall be drawn at a scale not smaller than one inch equals 200 feet, and not larger than one inch equals 50 feet:
a. The property lines of the parcel(s) on which the firing range(s) are to be developed,
b. For rifle and pistol ranges, the safety fan and its component parts with dimensions for all firing ranges; for shotgun firing ranges, the component parts and dimensions of the shotfall zones,
c. All existing and proposed structures on the range, labeled for their intended use,
d. The location and dimensions of all firing lines and firing positions,
e. The location and dimensions of all target lines and related facilities,
f. The locations, dimensions and slope of all backstops and side berms, whether natural or manmade; the volume, material and source of all imported materials shall be noted,
g. The locations and dimensions of all baffles; horizontal drawings of the baffles shall be included, and building materials shall be identified,
h. The location and dimensions of all walkways,
i. All screening, landscaping and fencing,
j. The location of all utilities, including but not limited to electrical, potable water, wastewater disposal, and drainage ways, both natural and artificial,
k. The location of all lighting facilities,
l. The location of all roads, driveways, and parking facilities, including the number of parking spaces, and
m. The location of all streams, watercourses, and wetlands on the property;
(4) For rifle and pistol ranges only, longitudinal cross-sections of that portion of each firing range from ten feet behind each firing line to ten feet beyond the downrange terminus of each direct fire zone, ten feet beyond the back toe of each backstop if manmade, or if natural, 20 feet beyond the front edge of the backstop, as applicable; and latitudinal cross-sections, from ten feet outside any side berms or the edge of each safety fan, of typical areas between each firing line and backstop or downrange terminus of the direct fire zone;
(5) A list of all property owners within 2,640 feet of the perimeter of the property on which the public outdoor shooting range is proposed for development;
(6) The land uses of all properties abutting the shooting range property;
(7) Other information deemed appropriate by the community development director.
(g) Inspections. No public outdoor shooting range shall commence operations until the range has been inspected and approved by the community development director to ensure that the facilities and development of the range conform with the conditional use permit issued.
(h) Liability for damages. The provisions of this section shall not be construed to hold the county, or any officer or employee thereof, responsible for any damages to persons or property by reason of the certification, inspection or non-inspection of any building, equipment or property as herein authorized.
(Ord. No. 06-2020, § 3, 12-8-2020; Ord. No. 16-2021, § 2, 8-10-2021) Sec. 114-742. Shooting ranges, indoor.
Indoor shooting ranges, including archery ranges may be permitted in B-2 districts, provided the following conditions are met:
(a) Building plans certified by a design professional are required. Plans shall include backstops, ventilation, bullet traps, bullet resistant material between each firing lane, lead abatement and noise buffering to meet or exceed all applicable State and federal laws and regulations.
(b) The operator shall cause a qualified design professional to perform annual inspections to verify continued compliance with all applicable design standards and safety procedures, a report of which shall be filed with the building official.
(Ord. No. 06-2020, § 3, 12-8-2020; Ord. No. 16-2021, § 2, 8-10-2021) Sec. 114-743. Solar energy system (SES).
(a) Generally. Solar energy systems (SES), also referred to as power generation facilities or solar farms, may be a primary or accessory use and shall comply with the following:
(1) The SES has a minimum of 25 acres, unless it is an accessory use;
(2) The SES property boundary is within two miles of an existing electrical transmission line if the SES is for commercial purposes; and
(3) A conceptual plan is submitted with the application demonstrating the SES will meet the design and development standards of this UDO.
(b) Development agreement. The county commissioners may require, at its sole discretion, a development agreement between the county and developers for properties developed as a SES or utilizing solar energy systems as a prerequisite to site plan approval.
(c) Design and development standards. The establishment and operation of a solar farm shall comply with the following specific design and development standards:
(1) Buffers are required as identified in Exhibit 742. This buffer is separate and distinct from the buffering requirements identified in article VI. Only the following activities shall be permitted within the landscaped buffer:
a. Vehicular access drives which tie into approved access points as determined by GDOT and/or the county;
b. Landscaping and landscaping fixtures;
c. Lighting;
d. Fencing; and
e. Signage.
(2) Landscaping/screening requirements. In addition to buffering, screening shall be required by providing landscape within the buffer which achieves a full screening of all proposed site improvements with a minimum height of ten feet within three years. The intent is to provide sufficient screening, through a combination of buffers, fencing, landscaping, and/or landscaped berms to obscure the solar equipment from exterior view from adjoining property owners and public right-of-ways.
(3) A visually opaque screen shall be provided for any adjacent property that is zoned RR, R or PD, has an existing residential use, and/or has been subdivided to five acres or less. An opaque screen is intended to exclude a visual contact with the solar equipment from any protected property, public street or public right-of-way. An opaque screen may be composed of a wall, fence, building, landscaping, landscaped berm, or combination thereof. Natural areas as detailed below may also be used to meet screening requirements.
(4) Natural areas are comprised of existing vegetated area located on the same property as the SES;
and is within or includes the required buffer; and is of sufficient height, length, and depth and contains adequate and sufficient healthy vegetation to provide a visually opaque screen where required. The community development director may determine that further screening improvements shall not be required.
(5) The setbacks for solar equipment associated with the solar energy system shall be 25 feet larger than the applicable bufferyard to allow for an access road around the perimeter of the property.
(6) A security fence shall be required at least six feet in height to secure the solar equipment unless a taller fence is needed in order to obscure the solar equipment from exterior view. The fence may be on top of the berm in order to achieve this goal. A chain link fence shall not be allowed unless it is screened from exterior view from adjoining property owners and public rights-ofway; screening may include plantings to create a "living fence", or to obscure the view of the fence. Breaks in fencing may be allowed or required by the board of commissioners to facilitate wildlife needs where natural features provide appropriate barriers to access by humans for security and safety purposes.
(7) The SES shall not exceed ten feet in height, as measured from the ground to the foremost/tip end of the solar collector, provided there is a demonstration that the screening prevents the system from being visible from the exterior of the property. Ancillary non solar collector structures, such as inverters, transformers, etc., may be taller than ten feet in height, provided that such are not visible from the exterior of the property.
Exhibit 742: Minimum SES Buffer Requirements Existing Use of Adjacent Properties and Minimum Buffer Widths Agricultural Single Family All Other Residential Uses Office/Institutional Commercial/Industrial Street 50' 200'1 200'1 50' 25' 100'2 1 Single Family Dwelling and all other residential use buffers may, at the board of commissioners' discretion, be increased, or reduced with an approved berm and /or landscaping and screening plan, which will screen the SES equipment from being seen from the exterior of the property.
2 Street buffer may, at the board of commissioners' discretion, be reduced to 50 feet with an approved berm and/or landscaping and screening plan, which will screen the SES equipment from being seen from the exterior of the property.
(d) General requirements. SES shall also comply with the following general site and development standards:
(1) Solar collectors shall be designed with anti-reflective coating to minimize glare. Mirrors are prohibited.
(2) On-site electrical interconnections and powerlines shall be installed underground to the extent feasible. Existing above ground utility lines shall be allowed to remain in their current location.
(3) A warning sign concerning voltage must be placed at the main gate that states the address of the site, the name of the SES operator, and a local phone number in the case of an emergency.
(4) Access to the site must be controlled by a six-foot wooden fence or gate, if the fencing is visible from the exterior of the property. If the fencing/gate is within the interior 25 percent of the buffer or is not visible from the exterior or the property, chain link gate and fencing may be used.
(5) Entrance roadway should include a dog leg or meander to obscure vision from the roadway.
(6) If lighting is provided at the site, lighting shall be shielded and downcast such that the light does not spill onto the adjacent parcel or the night sky. Motion sensor control is preferred.
(7) Adequate provisions to reduce average/constant noise levels at the property boundary, not to exceed 50 dBA at the property line, except during construction.
(8) A solar collection device or combination of devices are to be designed and located to avoid directing glare or reflection onto adjacent properties and adjacent roadways and shall not interfere with traffic or create a safety hazard.
(e) Site restoration/stabilization. Unless otherwise agreed to by the board of commissioners in its concept plan or development agreement approval process, the applicant shall submit a ten percent site restoration/stabilization guarantee in the form of a bond, irrevocable letter of credit, or other financial security acceptable to the county prior to issuance of the development permit. The site restoration/ stabilization guarantee shall insure satisfactory grading, seeding, and stabilization of the site in case of default by the applicant and/or if the applicant does not install the required site improvements in a timely fashion as determined by the engineering director, including the costs of landscaping, screening, and or fencing for the site or such portion thereof being permitted. The developer shall provide the county with an itemized engineer's cost estimate of the approved site improvements. The site restoration guarantee may be refunded upon issuance of the certificate of project close-out for the site stabilization and improvements.
(f) Decommissioning. Unless otherwise agreed by the board of commissioners in its concept plan or development agreement approval process, the applicant must provide a decommissioning plan signed by the party responsible for decommissioning and the landowner (if different) that describes the anticipated life of the SES, the estimated decommissioning costs in current dollars, the method for ensuring that funds will be available for decommissioning and restoration, and the anticipated timeline and manner in which the SES project will be decommissioned and the site restored to its condition prior to the development of the SES or such other conditions approved in the concept plan or required in a development agreement. If the property has been timbered within two years of conditional approval, original condition means replanted with timber. Decommissioning will be required following a continuous period of 12 months in which no electricity is generated by the facility other than for mechanical, repair, replacement and/or maintenance purposes. The permit holder will have 12 months to complete decommissioning of the SES. Decommissioning shall include removal of solar panels, foundations, structures, cabling, electrical components, conduit, and any other associated facilities as described in the commissioning plan.
(g) Performance guarantee. Prior to issuance of development permit, the applicant must provide the County with a performance guarantee in the form of a bond, irrevocable letter of credit and agreement, or other financial security acceptable to the county in the amount of 125 percent of the estimated decommission cost minus the salvageable value, or $50,000, whichever is greater. Estimates shall be determined by an engineer licensed to practice in Georgia.
(h) Updated engineer's cost estimate. Every five years a new engineer's cost estimate of probable cost of decommissioning shall be submitted for approval in the same manner as the initial submission, and the bond, letter of credit, or other financial security acceptable to the county shall be adjusted upward or downward as necessary.
(Ord. No. 06-2020, § 3, 12-8-2020; Ord. No. 16-2021, § 2, 8-10-2021) Sec. 114-744. Special events and temporary uses.
(a) Special events. Special events may be approved by the community development director pursuant to section 114-424 and the following requirements:
(1) Carnival or circus may be approved for a period not to exceed four weeks.
(2) Religious meetings in a tent or other temporary structure, may be approved for a period not to exceed 40 days, except in RR-1, R-15, R-M, R-MH or PD districts, the meeting period may not be longer than ten days.
(3) Restaurants requesting outdoor live entertainment with amplification may be approved for a period not exceeding three months. The restaurant owner may request additional special event permits within a calendar year, but collectively, outdoor entertainment shall not exceed six months in a calendar year. In approving the request for a special event permit, the community development director may include conditions reasonably necessary to limit noise and light impacts to surrounding property owners, address any increases in traffic and demand for parking.
(4) For other special events, the community development director may include conditions of approval reasonably necessary to protect the public health, safety and welfare.
(b) Temporary uses, generally. Temporary uses may be approved by the community development director pursuant to section 114-424 and the following requirements:
(1) If the applicant is not the owner of the property, the applicant shall provide written permission of the owner of the property to allow such an event prior to beginning such temporary use.
(2) A minimum of one parking space shall be provided for each 800 square feet of gross lot area used for the activity (not including storage areas) plus additional parking space for any structure utilized for retail sales computed in accordance with the parking requirements for retail stores.
(3) All equipment, materials, goods, poles, wires, signs, and other items associated with the temporary use shall be removed from the premises within two days of the end of the event.
(4) The length of a temporary use shall not exceed seven consecutive days or ten days cumulative in a six-month period.
(5) Temporary uses may be allowed on any lot with a permitted principal building.
(6) Temporary uses may be allowed on a vacant lot when providing the minimum setback for all buildings, structures, and parking required for the appropriate zoning district.
(7) In no case shall the setbacks for any buildings, structures or parking be less than ten feet.
(8) The temporary use must not prevent the continued use of sidewalks, rights-of-way, fire lanes, etc.
(9) The community development director may extend the time period for the temporary use permit so that a separate permit is not required for each event within any one calendar year, provided, the number of dates and a schedule shall be established at the time of application and all conditions and requirements of the community development director shall remain in force.
(c) Construction trailer/sales office. Construction trailers and sales offices are permitted provided:
(1) Only one construction trailer is allowed per developer/builder, except the maximum number of construction trailers in a development shall not exceed four;
(2) Only one trailer may be used for sales per development;
(3) The trailer shall be located within the project boundary;
(4) If the property has been subdivided, the trailer shall be located on a lot of record and meet applicable setbacks for the district;
(5) The applicant shall be responsible for providing or obtaining an address from 911 for the trailer;
and
(6) The construction trailer/sales office is not subject to the time limits identified in (b)(4) of this Section but shall comply with the provisions of Section 114-747.
(d) Temporary sale of consumer fireworks.
(1) Temporary structures for the sale of fireworks must be located within 1,000 feet of a fire hydrant or a fire department connection of a building unless the Bryan County Fire Chief gives permission in writing stating otherwise.
(2) The duration of a temporary consumer fireworks retail sales facility shall initiate upon approval and terminate within 90 days after initiation.
(e) Holiday Sales. Open lot sales of holiday goods, such as Christmas trees, pumpkins, etc., may be approved by the community development director for a period not to exceed 45 days.
(Ord. No. 06-2020, § 3, 12-8-2020; Ord. No. 16-2021, § 2, 8-10-2021) Sec. 114-745. Swimming pools.
(a) Swimming pools and above grade decks situated on a lot in a A-5, RR or R district and designed for use by a single family must meet the setbacks for accessory structures for the zoning district in which the pool is situated. The pool must have a barrier of not less than four feet in height. Where the top of the pool structure is above grade, such as an above-ground pool, the pool may be considered as part or all of the barrier or the barrier may be mounted on top of the pool structure to meet the required height. If the means of access for an above ground pool is a ladder or steps, the ladder or steps shall be capable of being secured, locked or removed to prevent access. All gates shall be self-closing with positive latch devices to ensure the pool is enclosed and secure at all times.
(b) For all other swimming pools, their contiguous decking, whether above or at grade, and accessory structures shall not be closer than 100 feet to any property line and shall be enclosed by a barrier of not less than five feet in height. All gates shall be self-closing with positive latch devices to ensure the pool is enclosed and secure at all times.
(Ord. No. 06-2020, § 3, 12-8-2020; Ord. No. 16-2021, § 2, 8-10-2021) Sec. 114-746. Telecommunications facilities.
Telecommunications facilities shall comply with chapter 113 of the Bryan County Code.
(Ord. No. 06-2020, § 3, 12-8-2020; Ord. No. 16-2021, § 2, 8-10-2021) Sec. 114-747. Temporary buildings and structures.
Temporary principal or accessory buildings and structures may be permitted, subject to approval by the community development director pursuant to section 114-424 (Temporary Use and Special Event Permits) and subject to the following conditions:
(a) Temporary buildings and structures may be used for the storage of construction materials, tools, supplies, and equipment for special events/temporary events (e.g., weddings, religious events, seasonal sales), and for temporary on-site sanitation, solid waste, or fuel facilities, related to construction activity on the same lot. The community development director may approve other buildings and structures provided the applicant can demonstrate public health, safety, and welfare will not be negatively impacted.
(b) Tents that encompass 120 square feet or more of floor area, permit a gathering of ten or more persons, or require a building permit under the Building Code shall be considered temporary structures and subject to all building and life safety codes.
(c) No temporary building or structure shall be used for dwelling purposes.
(d) Shipping containers are not considered temporary structures or buildings and may not be used for any use that would involve either occupancy by an employee or member of the public.
(e) Temporary buildings and structures shall be removed from the lot.
(1) Within 15 days after an occupancy permit is issued by the community development director for the permanent structure on such lot;
(2) Within 15 days after the expiration of a building permit issued for construction on such lot;
(3) When used for a major subdivision {e.g., sales office, construction trailer), after 90 percent of the lots have been sold for development;
(4) Within three days of completion of the temporary or special event; or
(5) As provided for in the special event/temporary use permit.
(f) Temporary buildings and structures must be identified on the temporary use or special event application identified in section 114-744. The community development director shall determine if a separate building permit is required.
(Ord. No. 06-2020, § 3, 12-8-2020; Ord. No. 16-2021, § 2, 8-10-2021) Sec. 114-748. Truck stops.
(a) Applicability. The standards of this section apply to all truck stops and travel plazas in addition to other applicable provisions of this UDO.
(b) Minimum parcel area and road frontage. The minimum parcel area for establishment of a new truck stop or travel plaza is ten acres with at least 200 feet of direct road frontage on a collector or arterial road.
(c) Location. The parcel on which the truck stop/travel plaza is located must be within 2,000 feet of the centerline of the nearest interstate highway exit/entry ramp.
(d) Parking and fueling stations. Fueling areas for automobiles and fueling areas for trucks must be separated. Pump island canopies may not exceed 22 feet in height.
(e) Operations.
(1) All activities and operations shall be conducted entirely within an enclosed structure, except as follows:
a. The dispensing of petroleum products, water and air from pump islands.
b. The provision of emergency service of a minor nature.
(2) No vehicle shall be parked on the premises for the purposes of offering the vehicle for sale and no used or discarded automotive parts or equipment or disabled, junked, or wrecked vehicles shall be located in any open area.
(f) Noise. If the parcel on which the truck stop/travel plaza is located is within 1,320 feet of an RR, R or PD zoning district, the applicant must provide a noise impact study prepared by a qualified acoustical consultant and must propose necessary mitigation measures to ensure that noise levels at the boundary of the nearest RR, R or PD zoning districts will not exceed 60 dBA between the hours of 10:00 p.m. and 7:00 a.m. The applicant must also propose idling time restrictions and means of ensuring compliance with such restrictions. The purpose of such restrictions is to reduce noise and air quality-related impacts.
Noise from bells or loudspeakers shall not be audible beyond the property line at any time.
(g) Parking. All parking areas must be paved and fully comply with current Bryan County landscaping and storm water management requirements. A parking lot separated from the truck fueling/parking area must be provided for employees and passenger vehicles utilizing the facility.
(h) Adult uses. No adult uses activities as defined by this UDO are permitted.
(i) Security. The truck stop/travel plaza must be designed with adequate lighting, fencing, security cameras, access control, signs, etc. to mitigate the potential for crime.
(j) Additional requirements. The community development director may require design changes or additional landscaping, screening, and berms as necessary to minimize the visual and noise impact of the truck stop or travel plaza on adjacent properties.
(Ord. No. 06-2020, § 3, 12-8-2020; Ord. No. 16-2021, § 2, 8-10-2021; Ord. No. 09-2024, § 2, 4-9-2024) Sec. 114-749. Vehicle sales.
This section applies to automobile, trailer, truck, farm equipment, heavy equipment, manufactured home, boat, recreational vehicle or motorcycle sales, and such sales shall comply with the following supplemental regulations:
(a) The minimum lot size shall be one acre with a minimum lot width of 200 feet.
(b) Signs shall conform to the requirements of article VI, division 8.
(c) Temporary or portable structures are not permitted.
(d) Outdoor displays shall conform to the following:
(1) Vehicles, for sale or otherwise, shall be parked on approved paved surfaces.
(2) Vehicle display areas shall not be located within any required streetyard or buffer area, as specified in article VI, division 5, and shall be outside of public rights-of-way.
(3) Vehicle display or storage shall not be allowed in areas required for visitor, employee or service parking.
(e) All other merchandise available for sale, including, but not limited to, clothing, accessories, tires, collectibles etc. shall be sold and displayed within an enclosed building.
(f) All service work, including vehicle washing, repair and general maintenance, shall be conducted entirely within an enclosed building.
(g) Audible paging systems or outdoor speakers are not permitted.
(h) The use of spotlights is prohibited.
(i) If the lot will be lighted at night, the property owner shall submit a lighting plan, including photometric details, with the site plan application.
(Ord. No. 06-2020, § 3, 12-8-2020; Ord. No. 16-2021, § 2, 8-10-2021) Sec. 114-750. Vehicle washing facilities.
The following regulations shall apply to all vehicle washing facilities, whether as a principal or accessory use:
(a) All washing activities other than drying of vehicles must occur inside a building.
(b) Required stacking spaces for waiting vehicles shall not be located within a public or private right- of-way and shall not conflict with maneuvering areas, parking spaces and other activities.
Stacking lanes shall be designed to prevent vehicle queues from extending beyond the property.
(c) Wastewater must be recycled, filtered or otherwise cleansed to minimize discharge of soap, wax and solid matter into public sewers.
(d) For automated drive-through wash facilities, a by-pass lane is required that allows by-passing waiting vehicles.
(e) Overhead doors shall not face a street, except as approved by the community development director in these circumstances:
(1) When the doors of a through-garage are located at the front and rear of a building; or
(2) When a garage is located on a corner or through lot; or
(3) When determined that a rear garage door would negatively affect an abutting residential use or district.
(f) A vehicle wash facility building and any accessory buildings and uses, including vacuums, shall be located at least 100 feet from a street right-of-way line and any RR, R, or PD district boundary.
(g) The property owner or operator must comply with all nuisance regulations. Air handling equipment shall be located on a roof, be equipped with intervening noise reduction baffles and be in proper working condition.
(Ord. No. 06-2020, § 3, 12-8-2020; Ord. No. 16-2021, § 2, 8-10-2021) Sec. 114-751. Wrecking, salvage, and junk yards.
Wrecking, salvage, and junk yards are subject to the following requirements:
(a) No yards shall be permitted closer than 500 feet to any RR-1, R-15, R-M or R-MH zoning districts as measured between the nearest property lines.
(b) All yards must be completely screened by a solid fence or wall a minimum of eight feet above grade. All such fences must be perpetually maintained in good condition and, except for masonry fences or walls, must be painted. Fences and walls associated with this requirement are not subject to the height limitations identified in section 114-632(d). Final height shall be approved by the Community Development Director based on the screening objectives of these supplemental requirements, the adjacent uses, topography, and location of storage areas.
(c) No materials shall be stacked higher than the screen fence or wall.
(d) There shall be no temporary or permanent storage at a yard of vehicles or junk outside the fence or wall required by paragraph (b) of this section.
(Ord. No. 06-2020, § 3, 12-8-2020; Ord. No. 16-2021, § 2, 8-10-2021) Secs. 114-752—114-799. Reserved.
ARTICLE VIII. DEVELOPMENT PATTERNS AND DESIGN
This article includes design standards and guidelines for different development patterns.
Sec. 114-800. Purpose.
To fulfill the county's comprehensive plan's goals and objectives and ensure the county develops in a manner consistent with these goals and objectives, this UDO provides for development patterns, design standards and design guidelines for residential and non-residential development. The purposes of establishing these patterns, guidelines, and standards are:
(a) To achieve building and site design that is compatible with the neighborhood setting while avoiding monotonous uniformity;
(b) To protect property values and enhance the value of public and private investments through well-planned and well-maintained development;
(c) To promote creative designs that surpass the quality of the minimum design standards established herein;
(d) To foster safe, healthy and sustainable development that becomes increasingly valued in Bryan County as desirable places to live, work, play, and shop;
(e) To ensure that the scale, massing, and building details are in proportion to and complementary with the surrounding neighborhood;
(f) To require materials that are durable in the county's environment;
(g) To foster site development that reflects and reinforces the natural beauty of Bryan County;
(h) To retain the rural character of the county;
(i) To protect the health, safety, and welfare of the general public and occupants of the buildings;
(j) To promote a pedestrian-friendly, walkable streetscape within and between developments;
(k) To provide for aesthetically pleasing development patterns;
(l) To promote economic vitality within the county;
(m) To promote a good business environment serving the needs of the residents and visitors to the county; and
(n) To create compatible land use transitions between residential and non-residential developments.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-801. Modification of standards.
Unless otherwise noted in the provisions of this article, the community development director may modify building and site design standards upon determining that the applicable design purposes are satisfied. Appeals to the community development director's actions shall be considered by the planning and zoning commission. Any of the provisions of this article may be modified through the planned development process.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-802. General design standards.
Subsequent sections for each development pattern, e.g., single-family, townhouse, multi-family, etc., will identify specific design standards. The objective of design standards for the county is to select building and site design that is compatible with and maintains the rural character while the county transitions, in certain areas, to a more urban environment. Generally, development should be consistent with the Georgia Coastal Regional Character Design Guidelines prepared and published by the Coastal Regional Commission June 30, 2010, ("CRC Design Guidelines") and all subsequent revisions. Depending on the location, development should be consistent with the design guidelines established for Rural Ridge, Southern Coastal Plain, Tidewater Hearth or Barrier Island and Marsh Fringe character areas (collectively "CRC character areas").
Development, therefore, should include the following:
(a) Open space;
(b) Pedestrian and bicycle connectivity, as appropriate;
(c) Walkable and pedestrian friendly features, including outdoor gathering places;
(d) Streetscapes that define the pedestrian and vehicle corridor and presents an appealing and continuous theme along a sidewalk or road;
(e) Design elements that limit long blank walls and/or deemphasize the mass of structures;
(f) Native vegetation that is incorporated into landscaped areas and promotes the protection of the natural environment by limiting clearing, grading, and land disturbance as much as possible;
(g) Existing natural features, such as protected trees/tree clusters, topography and creeks, that are incorporated into the site planning and enhance the natural environment; and
(h) Buildings and structures compatible or consistent with the Tidewater Hearth, Southern Coastal Plain or Barrier Island and Marsh Fringe Character Areas in South Bryan or the Rural Ridge Character Areas in North Bryan, that generally reflect or are complementary to a low-country architectural style.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-803. Single-family and duplex development.
(a) Applicability. The design standards in this section apply to all new detached single-family and duplex residential construction, except for the following:
(1) Development within a manufactured housing park or manufactured home subdivision;
(2) Development of a parcel that is not platted as part of a major subdivision or was created through a minor plat;
(3) Any parcel in an A or RR zoning district;
(4) Any parcel that is part of an approved PUD for which the approval included residential design guidelines/standards or deed restrictions addressing similar residential design requirements;
(5) Any parcel for which a sketch plat and construction plans have been approved prior to adoption of the IDO or this UDO shall be exempt from the provisions of single-family and duplex residential design standards; provided the sketch plat and construction plans do not expire. If a sketch plat and construction plans, however, were approved pursuant to the IDO requirements, the applicant may develop under the IDO standards in existence at the time of approval or they may develop under the UDO standards. If the sketch plat and/or construction plans approved under the IDO requirements expire prior to development commencing, the structures must be constructed to these UDO requirements; and
(6) Those areas within a pending subdivision that the community development director determines to function as a transition areas as identified in section 114-107. In these areas, the community development director may modify any of the standards and guidelines in this section to achieve compatible transitions.
(b) Theme. In developing single-family detached and duplex sites, the design of buildings should be consistent with the county's overall goal of developing in a low-country style and consistent with the design guidelines identified in the CRC Design Guidelines.
(1) Southern Coastal Plain, Tidewater Hearth and Barrier Island and Marsh Fringe areas generally include the following elements:
a. Raised buildings/elevated slabs;
b. Broad hip roofs;
c. Covered wraparound porches;
d. Functioning shutters; and
e. Transoms.
(2) Rural Ridge areas generally include the following elements:
a. Materials such as brick, wood/composite shake or lap siding;
b. Broad overhangs and projections for eaves; and
c. Fenestration delineation, i.e., divided lites (windowpanes).
(c) Building design. Applicable single-family and duplex developments are required to comply with the following building design standards.
(1) Materials and finishes. All primary buildings shall comply with the following:
a. Exterior walls shall be finished in brick, tabby, stone, stucco, or composite shake, lap siding, wood or fiber-cement siding. Metal or aluminum may be used as an accent material. The use of vinyl or other plastic siding or metal siding is strictly prohibited except as provided for in paragraph (d) of this section.
b. Not more than two building materials shall be used for exterior walls (excluding trim and cornices) on sides of buildings facing or visible from a road. If a single material is proposed, but there are multiple textures and/or colors, the community development director shall determine if the overall effect is inconsistent with the intent of this provision.
c. Roofs shall be galvanized (standing seam or v-crimp), slate, wood or composite/ manufactured shingle, architectural shingle, or other roofing material approved by the community development director.
d. A maximum of two additional materials may be used for accents, but the material used must be listed in paragraph a. Fascia, soffits, and other house trim materials may be vinyl.
e. Windows shall have exterior trim. The use of fiber cement, composite, or wood for trim is encouraged over the use of vinyl or PVC trim.
f. The following materials are prohibited and may not be modified by the community development director or planning and zoning commission:
1. Metal or aluminum siding as a primary building material;
2. Unfinished concrete block, concrete tilt slab, or block siding; and
3. Vinyl siding. Fascia, soffits, and other trim materials, however, may be vinyl.
(2) Design features.In developing single-family detached subdivisions, developers shall incorporate required design features and a minimum number of optional features, many of which are illustrated in Exhibit 803. If the developer cannot meet these minimum standards, the developer may propose alternative design features that are consistent with the purposes of this article, for the community development director's review and approval.
a. Required features. Single-family homes and duplexes shall incorporate the following design features:
1. Front entry garages shall not exceed 50 percent of the building width.
2. Side entry garages shall have windows comprising at least ten percent of the front facing wall.
3. All slabs shall be elevated for development located in the Tidewater Hearth, Southern Coastal Plain or Barrier Island and Marsh Fringe character areas. The finished floor elevation at the front façade shall be located above grade in accordance with the following standards:
i. The foundation supporting the floor framing on the front façade shall be a minimum of 18 inches above grade;
ii. Exposed foundation walls or piers shall be clad in face brick, stone, tabby, or some other masonry material accurately imitating these materials. Concrete shall not be considered an acceptable masonry material. Latticework screening or similar type screening shall be installed between piers on front and side building facades.
4. Entries shall be located at the front of the building and connected to a paved driveway or sidewalk by a clearly delineated pedestrian walkway.
5. Entries for single-family homes shall be covered by a roof measuring not less than four feet in depth by six feet in length.
6. Large expanses of blank walls shall be broken up by features such as windows, doors, window reveals, offsets, balconies, projections, recessed or covered entrances, porches or similar elements that comprise not less than 15 percent of the streetfacing wall.
b. Optional features. While each of the following design features is desirable, single-family and duplex residences shall incorporate at least three the following design features:
1. Side or rear entry garages or detached garages.
2. At least three roof planes visible from front property line.
3. Minimum roof pitches of 4:12 (rise:run) for all planes visible from the front of the structure, with the exception of roofs over covered porches, carports, shed dormers, and accessory structures.
4. Covered porches that are at least five feet in depth at the base. If providing a wraparound porch, the porch shall count for two design features.
Exhibit 803: Sample Illustration of Single-Family Residential Design Features
(3) Duplex design. The following provisions shall apply to the design of duplex dwellings in addition to the provisions of paragraphs (c)(1) and (2) (Materials and Finishes and Design Features) of this section:
a. Transparent windows and/or doors on at least 15 percent of the facade (this includes any upper levels, if applicable).
b. Corner lot duplexes shall be designed with the front pedestrian entry of each unit located on a different street frontage.
c. Covered entries for each dwelling unit shall be provided with a minimum dimension of four feet in depth by six feet in length.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-804. Townhouse development.
Townhouse developments are subject to the applicability requirements identified in section 114-803(a) and shall be consistent with the design themes identified in section 114-803(b). Townhouse developments are required to comply with the following design standards.
(a) Materials and finishes. All primary buildings shall comply with the following:
(1) Exterior walls shall be finished in brick, tabby, stone, stucco, or composite shake, lap siding, wood or fiber-cement siding. The use of vinyl or other plastic siding or metal siding is strictly prohibited except as permitted in paragraph (d).
(2) Not more than two building materials, per unit, shall be used for exterior walls (excluding trim and cornices) on sides of buildings facing or visible from a road. For townhouse developments, the material finishes are per building. The community development direcUNIFIED DEVELOPMENT ORDINANCE § 114-804 tor may allow the use of additional building materials upon reviewing proposed renderings and determining the design is compatible with the goals and objectives of this UDO.
(3) Roofs shall be galvanized (standing seam or v-crimp), wood or composite/manufactured shingle, architectural shingle, or other material approved by the community development director.
(4) The development may use different materials for accent, but the material used must be the ones identified in paragraph a. No more than two additional materials, per unit, may be used for accent. Fascia, soffits, and other house trim materials, however, may be vinyl.
(5) Windows shall have exterior trim. The use of fiber cement siding, composite, or wood for trim is encouraged over the use of vinyl or PVC trim.
(b) Design features. Similar to single-family subdivisions, townhouse developments are required to include certain design features and a certain number of optional features. If the developer is unable to provide these design features, the developer may propose alternative design features, consistent with the county's goals and objectives, for the community development director's review and approval.
(1) Required features. Townhouse development shall incorporate the following design features:
a. Street and rear yards shall be provided for all townhouses, but side yards are only required for exterior townhouses. Building separation requirements shall be maintained for all townhouse structures.
b. The maximum number of units allowed in a single building is eight.
c. If the garages are not rear loaded, the following standards apply:
1. Garages must be inset a minimum of one foot; and
2. Where garage doors for separate units are adjacent, they shall be offset from each other and at least one unit must feature single-car garage doors.
d. Carports are prohibited.
(2) Optional features. While each of the following design features is desirable, townhouse developments shall incorporate at least three the following design features:
a. Rear-loaded garages.
b. For multi-car garages (front loaded), paired-single doors.
c. Changes in massing particularly over garages doors. The use of insets or projecting bays are preferable and encouraged.
d. Elevated slabs. The finished floor elevation at the front façade shall be located above grade in accordance with the following standards:
1. The foundation supporting the floor framing on the front façade shall be a minimum of 18 inches above grade;
2. Exposed foundation walls or piers shall be clad in face brick, stone, tabby, or some other masonry material accurately imitating these materials. Concrete
shall not be considered an acceptable masonry material. Latticework screening or similar type screening shall be installed between piers on front and side building facades.
e. Covered porches that are at least five feet in depth at the base. If providing a wraparound porch for the end units, the porch shall count for two design features.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-805. Multi-family development.
(a) Applicability. The provisions of this section shall apply to all new multi-family residential developments with five or more dwelling units in any zoning district. The following multi-family developments are exempt from these requirements:
(1) Multi-family developments with site plans approved prior to the adoption of the UDO. If development is not commenced within 18 months of adoption, the development shall comply with the requirements of this UDO. For purposes of interpreting this exemption, the submittal of a concept plan with a rezoning application, including a PD, shall not constitute an approved site plan.
(2) Development with an approved site plan pursuant to the IDO design standards. The developer may, however, choose to develop under the UDO standards. If the approved site plan, however, expires (see section 114-419) prior to construction commencing, the development will need to comply with the UDO design standards.
(3) Multi-family developments included in a PD approved prior to the adoption of this UDO, and the PD has approved design guidelines/standards.
(b) Theme. Multi-family sites and buildings should be consistent with the county's overall goal of developing in a low-country style with the design patterns identified in the CRC Design Guidelines.
Development should avoid inappropriate elements.
(1) Inappropriate elements. Modern design features are considered inappropriate and the following design features should be avoided:
a. Monotonous barracks style buildings with long façades lacking roof and wall articulation as viewed from public roads;
b. Modern architectural design that incorporates glass, steel and reinforced concrete; and
c. Styles more appropriate in other regions of the country, such as Colonial, Cape Cod, and Northwest Regional style.
(2) Appropriate elements. These elements include features that are consistent with or further the county's design aesthetic of low-country style architecture.
a. Southern Coastal Plain, Tidewater Hearth and Barrier Island and Marsh Fringe areas generally should include the following elements:
1. Broad hip roofs;
2. Front porches and/or balconies;
3. Functioning shutters; and
4. Transoms.
b. Rural Ridge areas should generally include the following elements:
1. Materials such as brick, wood/composite shake or lap siding;
2. Overhangs and projections for eaves; and
3. Fenestration delineation, i.e., divided lites (windowpanes).
(c) Building design. Multi-family development shall comply with the following design standards, which are illustrated in Exhibits 805a and 805b:
(1) Materials and finishes.
a. Buildings shall use distinct, but complementary, materials and colors using a combination of the following materials:
1. Stucco with smooth, sand or light lace finish as a primary or accent material;
2. Engineered fiber-cement board or wood, as a primary or accent material;
3. Brick, as a primary or accent material;
4. Split-faced block, as a primary or accent material;
5. Stacked stone, as an accent material;
6. Marble, travertine, or other related stone materials as accent materials; and
7. Unglazed tile as an accent material;
b. The following materials are prohibited and may not be modified by the community development director or Planning and Zoning Commission:
1. Metal or aluminum siding, but metal and aluminum may be used as an accent material;
2. Unfinished concrete block, concrete tilt slab, or block siding; and
3. Vinyl siding. Fascia, soffits, and other trim materials, however, may be vinyl.
(2) Design features. In developing multi-family buildings, developers shall incorporate required design features and a minimum number of optional features, many of which are illustrated in Exhibits 805a-c. If the developer cannot meet these minimum standards, the developer may propose alternative design features that are consistent with the purposes of this article, for the community development director's review and approval.
a. Required features.
1. Roofs. Gable or hip roofs or a mixture of roof types to create articulation and ridgelines is required to break up long roof lines. Large expanses, or gambrel roofs, are prohibited.
Exhibit 805a: Sample Illustrations of Multi-family Design Features
2. Windows and doors.
i. Windows shall be rectangular, except accent windows may be round headed with various forms or other approved shapes.
ii. Arches, gateways, entry courts shall be used to shelter doorways.
iii. Windows shall be located to minimize views of the private outdoor space of adjacent units' patio areas.
iv. Windows and doors shall not include silver or gold window frames; reflective glass; or windows flush with wall surface.
Exhibit 805b: Sample Illustration of Multi-family Design Features
3. Stairways. Stairs shall be designed according to the following techniques:
i. Freestanding stairways shall not make a straight run from upper floors to the ground floors - they must have a landing and make a right-angle turn.
ii. Stairway walls shall be smooth or sand finish stucco, block, stone, slate, or other opaque building material with an accent trim cap or banding of tile.
iii. Exposed prefabricated metal stairs and transparent walls are prohibited.
4. Cable and antennas. All antennas shall be placed in attics or interior of the residence.
Developments shall be pre- wired to accommodate cable or satellite reception.
Satellite dishes are permitted to serve individual units.
5. Garage doors. Garage doors shall appear to be set into the walls rather than flush with the exterior wall.
Exhibit 805c: Sample Illustration of Multi-family Design Features
6. Roof mounted equipment. Roof mounted mechanical equipment other than solar energy systems shall be screened from view in a manner consistent with the building façade.
7. Ground mounted equipment. Ground mounted mechanical equipment shall be screened from view with landscaping or solid fencing.
b. Optional features. Multi-family development shall incorporate three of the following design features.
1. Awnings. Metal or canvas awnings of solid accent colors provided along ground level openings. Vinyl awnings are specifically prohibited.
2. Balconies. Balconies and porches provided at a ratio of no less than one per every three units.
3. Windows. Windows with true divided lites or simulated divided lites.
4. Eaves. Eave treatments for each building within the development that are consistent with the CRC Design Guidelines.
(3) Building massing.
a. Building separation. The minimum spacing between buildings is 20 feet, plus one foot for each one foot of building height in excess of 30 feet.
b. Building length. In attached multi-family projects, buildings shall not exceed 160 feet in length. Building façades should be broken up to reduce massing by changes in rooflines and offsets in walls. Wall offsets of at least two feet shall be provided at separations not exceeding 50 feet.
c. Clustering and massing. Clustering of multi-family units shall be a consistent site planning element. Buildings shall be designed as a series of varied plans that:
1. Vary setbacks within the same building;
2. Use reverse building plans to add articulation; and
3. Vary wall and rooflines.
(d) Accessory buildings. Accessory buildings are permitted within multi-family developments, so long as they are for the exclusive use of the residents. Building design shall comply with the following standards:
(1) Are limited to a single story in height;
(2) Shall use the same siding materials and be designed to reflect the style of multi-family buildings;
and
(3) Shall use the same roofing materials and have rooflines that reflect those of the multi-family buildings.
(e) Lighting. Outdoor area lighting shall be provided as required in article VI. Such lighting shall be shielded to direct light downward and not into dwelling units on, or adjacent to, the multi-family site.
Lighting shall be provided to illuminate the intersections of primary interior driveways and building entryways. Lighting fixtures shall comply with the character areas standards identified in the CRC Design Standards.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-806. Commercial development.
(a) Applicability. These design standards and guidelines shall apply as follows:
(1) All new commercial and mixed-use development and redevelopment projects in the B-1, B-2, P/I, and C-I districts requiring site plan approval shall comply with the standards and guidelines of this section. When applying these design standards, the objectives should be considered in the context of whether the development is small-scale commercial, which is generally development in the B-1 zoning district or projects with total gross floor area less than 10,000 square feet for single tenant or 40,000 square feet for multi-tenant or large-scale development.
(2) For projects involving remodeling or improvements to an existing structure built prior to this UDO, the owner shall bring the entire building into compliance with the design standards if the total cost of improvements is equal to or greater than 50 percent of the assessed value of the building improvements according to the most recent property tax assessor's records. Existing rooflines and locations of walls do not need to be brought into conformance.
(3) For projects involving the expansion of an existing building or overall square footage of development, the expansion shall be constructed in compliance with these design standards, as practicable. The community development director shall determine which standards can be reasonably met and are consistent with the goals and objectives of this UDO.
(4) If a development received site plan approval prior to the adoption of this UDO, the design standards in existence at the time of approval shall apply. If the site plan approval expires (see section 114-419), these UDO design standards shall apply to the development.
(5) The approval of a preliminary commercial subdivision plat or recording of a final commercial subdivision plat does not exempt structures/development from these design standards unless a site plan has been approved prior to the adoption of this UDO and remains valid.
(b) Theme. In developing commercial projects, the sites and buildings should be compatible with the county's overall goal of developing in a low-country style and be consistent with the design patterns identified in the CRC Design Guidelines, while being context appropriate especially for commercial development along major highways and interchanges. Generally, commercial development along minor roads and within less dense areas should have a more residential design approach, i.e., incorporating architectural elements like shutters, porches, etc. Large-scale commercial/auto centric development should incorporate design elements that reduce the scale and massing and use sustainable high quality building materials. Appropriate design elements include:
(1) Use of materials compatible with the design guidelines for the specific CRC character areas including brick, wood, tabby, and composite siding;
(2) A unified design theme that minimizes corporate logos and use of corporate architecture;
(3) Use of a neutral color palette, unless located in the Barrier Islands and Marsh Fringe CRC character area;
(4) Signage that is complementary to the building design and does not dominate the landscape or building facade;
(5) Buffering and landscaping of large-scale commercial structures/buildings to minimize the visual impact;
(6) Public plazas for large-scale development that emphasize the active nature of these spaces and incorporate some combination of accent items such as: site furniture (tables, umbrellas, benches, trash receptacles); shade structures; interesting colors and materials; or other focal elements;
and
(7) Strategic site planning for large-scale development that reduces potential nuisances to adjoining residential property by locating trash enclosures, loading areas, and restaurant vents away from residential uses and properly screening utilities and equipment.
(c) Building design. Commercial development shall comply with the following design standards:
(1) Materials and finishes. Generally, architectural features should be architecturally valid, not just decorative. While some elements may be wholly decorative, primary architectural features should be related to the building's structure, function and/or engineering, and should not be arbitrary.
a. Buildings shall use distinct, but complementary materials and colors consistent with the CRC design guidelines for the applicable character area, using a combination of the following materials:
1. Stucco with smooth, sand or light lace finish as a primary or accent material;
2. Engineered fiber-cement board or wood, as a primary or accent material;
3. Brick, as a primary or accent material;
4. Split-faced block, as a primary or accent material;
5. Stacked stone, as an accent material;
6. Marble, travertine, or other related stone materials as accent materials;
7. Unglazed tile as an accent material;
8. EIFS used in combination with another material, when the secondary material comprises a minimum of 25 percent of wall area below the roofline; and
9. Finished concrete tilt up, as approved by the community development department.
b. The following materials are prohibited and may not be modified by the community development director or Planning and Zoning Commission:
1. Metal or aluminum siding, but metal and aluminum may be used as an accent material;
2. Unfinished concrete block, unfinished concrete tilt slab, and block siding; and
3. Vinyl siding. Fascia, soffits, and other trim materials, however, may be vinyl.
(2) Design features. To ensure high quality and sustainable commercial development, certain design features are required for all commercial development regardless of size; plus, a certain number of optional design features are required. Large-scale development has supplementary required design features. Sample illustrations of some of these design standards are provided in Exhibits 806a-d.
a. Required features. All development shall include the following features:
1. Primary facades shall have a heightened level of detail and articulation. Rooflines, wall planes, and wall heights should be varied and significantly articulated to avoid blank expanses of walls. While all building elevations of a structure will not have the same level of detailing and articulation, elements of the architectural style shall be evident on the secondary façades of the buildings within the development.
2. Long facades shall include off-sets and other design features to create the appearance of multiple storefronts that are no more than 50 feet wide.
3. Pitched roofs shall be hip or gable and have a minimum pitch of six/twelve (6/12).
The community development director may approve flat or slightly pitched roofs for larger buildings; provided parapets with varied elevations are incorporated into all sides of the building design to avoid the appearance of long flat rooflines.
4. Windows and other openings shall be provided along all facades that face a public road or include customer entries. Windows and doors shall comprise at least 20 percent of the wall area below the roofline, lowest point of canopy, bottom of porch fascia or other architectural feature defining the middle of the building. Shapes and panes of the windows and openings shall be taller than wide.
5. Architectural features shall be used to provide weather protection and highlight building features and create a sense of entry.
Exhibit 806a: Sample Illustrations of Design Features for Commercial Development
b. Optional features. All development shall incorporate, at least, four of the following optional design features.
1. Windows and openings.
i. Windows/openings exceeding the minimum percentage requirement identified in (a)(4) above.
ii. Decorative trim and detailing along pedestrian areas of the building, such as around display windows and entries.
iii. Fenestration delineation, i.e., use of muntins to create divided lites (windowpanes) iv. Cornice trim at the eaves and in the gables.
2. Roof overhangs projecting at a minimum of eight inches. Overhangs shall either have open rafters or the appearance of rafters.
3. Appropriately sized shutters that are functional or appear functional.
4. Wood or composite exterior doors for primary entrances and along pedestrian areas of the building.
5. Balconies, awnings, canopies, arcades, wall insets, reveals or similar element, which give a person a sense of their relationship to the structure and provide a human scale.
c. Additional requirements for large-scale development. The following standards and guidelines apply to developments with single tenant greater than 10,000 square feet or multitenant building greater than 40,000 square feet in total floor area.
1. Retail and service commercial, office, community facilities, and mixed-use development with multiple structures or tenants, should use a "village" or "campus" design concept that integrates clusters of buildings with a combination of walking, landscape, and public space to achieve a desirable pedestrian experience. Site circulation for such developments should consider the functional relationship between buildings, as well as the access and movements of both vehicles and pedestrians, with the goal of providing a safe, convenient, and desirable experience for the user.
Exhibit 806b: Sample Illustration of Design Features for Commercial Development
2. Development with multiple buildings or tenants shall be designed with one or more pedestrian features. The number, size, location, and particulars of pedestrian ameUNIFIED DEVELOPMENT ORDINANCE § 114-806 nities will be evaluated on a case-by- case basis taking into consideration the proposed use and development of the site, as well as the relationship to the surrounding neighborhood and street network. Potential pedestrian features, though not exhaustive, are listed below.
i. Covered pedestrian walkways along storefronts connecting all entrances. Such walkways shall be primarily covered with building overhangs, trellises, awnings, or a combination thereof;
ii. Pedestrian courtyard(s) and/or plaza(s); or iii. Primary materials that clearly delineate pedestrian walkways such as broom finish concrete and secondary materials such as colored concrete or brick or concrete pavers.
3. The incorporation of public gathering places may be required depending on the size, scale, and location of the development. When required, the following objectives apply to the design of pedestrian gathering places.
i. Design of public plazas should emphasize the active nature of these spaces and incorporate some combination of accent items such as: site furniture (tables, umbrellas, benches, trash receptacles), shade structures, interesting colors and materials, or other focal elements.
ii. Design and layout of plaza areas shall consider the local climate and seasonal conditions and provide protections from the sun, wind, and rain.
(d) Project entry landscape. The vehicular entrance to the project should be clearly defined and provide adequate sight distance for vehicles and pedestrians. Entries to multi-tenant projects shall be designed as special statements reflective of the character and scale of the project in order to establish identity for tenants, visitors, and patrons. Landscape design at project entries shall complement any special landscape treatment at intersections of arterial and collector roads or local roads that intersect with arterial/collector roads with common elements. Flowering accent plantings and specimen trees shall be used to reinforce the entry statement. Planting design should have focal points at project entries, plaza areas, and other areas of interest using distinct planting and/or landscape features.
(e) Landscape for public plazas and building fronts. Landscaping shall be provided along all building facades facing a parking lot or street to soften the appearance of the structure and enhance the pedestrian scale and streetscape. In-ground landscaping should comprise the majority of the landscaping requirement. If raised planters are determined to be acceptable, they shall be designed to accentuate the architecture and/or enhance pedestrian areas. All planting materials shall be sized so that landscaping has an attractive appearance at the time of installation and an established appearance within three years of planting.
Exhibit 806c: Sample Illustration of Design Features for Commercial Development
(f) Mass, scale, and form. Architectural scale, for purposes of these guidelines, is the relationship between the size of the new buildings and the size of surrounding buildings. Scale also refers to how the size of the building relates to the size of a human being (human scale). The apparent scale of a building should be reduced through the proper use of window patterns, roof overhangs, equipment bays that screen unsightly elements, awnings, moldings, fixtures, the use of darker or subdued colors, upper story setbacks, building and roof articulation and other details.
(1) Site edge. The building(s) should be compatible with the scale of adjoining development. Where surrounding development is of a small-scale, large-scale buildings should be located internal to the site and transition down in scale as the outer edge of the site approaches.
(2) Building height. The design of larger non-residential buildings shall be designed to reduce the perceived building height and length by dividing the building mass into smaller scale components. This may be achieved by providing a well-defined base, middle and top to the building as described below:
a. A solid building base may be achieved by elements such as low planters and walls, a base architectural veneer banding (wainscot), or treatments defined by a different material, texture or color.
b. A solid building middle (and a more articulated building mass) may be achieved by the addition of intermittent covered walkways, trellises or architectural awnings that provide deep shadow at ground level.
c. A solid building top may be achieved by using features such as multiple architectural roof forms, clearly pronounced eaves, and distinct parapet designs and cornice treatments.
Exhibit 806d: Sample Illustration of Design Features for Commercial Development
(g) Site furnishings. If site furnishings are provided, furniture shall be selected not only for its functional and aesthetic qualities but also for the quality of materials and finishes that provide long-term durability and resistance to vandalism and climate/sun damage.
(h) Trash/recycling. Trash enclosures and containers shall be sized to accommodate the volume of refuse, but developers should also take advantage of opportunities to centralize enclosures where there are multiple buildings or users. The use of hydraulic compactors are prohibited except where entirely enclosed within a building. Trash enclosure materials and colors shall be consistent with and complementary to the building materials and finishes and comply with the screening requirements in section 114-632.
(i) Lighting. Outdoor area lighting shall be provided as required in article VI. Such lighting shall be shielded to direct light downward and not into dwelling units adjacent to the commercial development.
Lighting shall be provided to illuminate the intersections of primary interior driveways and building entryways. Lighting fixtures shall comply with the character areas standards identified in the CRC Design Standards.
(j) Sign regulations. In addition to complying with the general and specific sign standards in article VI, development shall comply with the sign standards for the applicable character area identified in the CRC design guidelines.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-807. Industrial development.
(a) Applicability. These design standards shall apply as follows:
(1) The provisions of this section apply to new development and redevelopment within the I-1 and I-2 districts.
(2) Redevelopment or remodeling projects that involve construction costs equal to or greater than 50 percent of the assessed value of site improvements according to the most recent property tax rolls shall be brought into conformance with the provisions of this section except that existing nonconformities due to existing rooflines and the existing locations of walls and parking areas may be retained.
(3) For projects involving the expansion of an existing building or overall square footage of development, the expansion shall be constructed in compliance with these design standards, as practicable. The community development director shall determine which standards can be reasonably met and are consistent with the purposes of this UDO.
(4) If a development has received site plan approval prior to the adoption of this UDO, the design standards in existence at the time of approval shall apply. If the site plan approval expires (see section 114-419), these UDO design standards shall apply to the development.
(5) The approval of a preliminary industrial subdivision plat or recording of a final industrial subdivision plat does not exempt structures/development from these design standards unless a site plan has been approved prior to the adoption of this UDO and remains valid, as required by this UDO.
(b) Theme. In developing industrial projects, a balance should be achieved between the practical and functional requirements of industrial uses with the overall goals and objectives of the county to obtain high quality, durable, and attractive development complementary to the low-country style of architecture envisioned for residential and commercial areas. Appropriate or expected design elements include:
(1) Coating, color, and exterior finishes to walls, especially concrete tilt up, to provide a more visually appealing facade;
(2) Architectural elements to reduce the appearance and scale of massing;
(3) Windows, openings, or voids to add variation to the building;
(4) Signage that is complementary to the building design and does not dominate the landscape or building facade;
(5) Buffering and landscaping of large-scale industrial structures/buildings to minimize the visual impact; and
(6) Strategic site planning for large-scale development that reduces potential nuisances to adjoining residential property by locating trash enclosures, loading areas, and outdoor storage and uses away from residential uses and by proper screening of utilities and equipment.
(c) Building design. Industrial development shall comply with following design standards and guidelines.
(1) Materials and finishes.
a. Buildings shall use distinct, but complementary materials and colors consistent with the surrounding areas. When two or more materials are used on an exterior wall, the heavier material (e.g., brick) shall be placed below the lighter material (e.g., stucco). The following materials are permitted:
1. Tilt-up concrete or concrete block. Exterior walls visible from the public right-ofway, private roads, or adjacent properties to the industrial property or park, must be painted or include exterior finishes such as coating or thin brick;
2. Brick;
3. Stone;
4. Stucco or synthetic stucco;
5. Cement-board or wood siding; and
6. Materials approved by the community development director, unless specifically prohibited in paragraph b.
b. The following materials are prohibited and may not be modified by the community development director or Planning and Zoning Commission:
1. Aluminum siding but it may be used as an accent material or on walls not visible from an existing or planned public street or an adjacent parcel located outside the industrial development. The accent material, cumulatively, may not exceed 20 percent of the area of any individual exterior wall visible from a public street or adjacent development;
2. Unfinished concrete block, unfinished concrete tilt slab, and block siding;
3. Highly reflective, shiny or mirror-like materials; and
4. Vinyl siding. Fascia, soffits, and other trim materials may be vinyl.
c. The community development director may approve alternative building materials and finishes for walls that are not visible from roads abutting the applicable industrial development or from adjacent properties that are not located within the applicable industrial development.
(2) Design features. To ensure high quality and sustainable industrial development, the following design features shall be incorporated. Sample illustrations are provided in Exhibit 807.
a. For non-manufacturing or non-warehouse type buildings, building mass must be reduced to smaller components with the use of jogs, offsets or other architectural features to reduce the visual length of long walls;
b. For manufacturing and warehouse type buildings, the length and height of walls must be relieved through the use of change in color, materials and/or relief such as the inclusion of pilasters, pop outs, etc.
c. All sides of a building shall be coherently designed and treated. A consistent level of detailing and finish is required for all sides of a building, especially when visible from public right-of-ways, private roads, or adjacent properties (outside of the industrial park).
d. Average parapet height shall not exceed 15 percent of the supporting wall height. Maximum parapet height shall not exceed 33 percent of the supporting wall height.
e. Design elements. For building facades that are visible from streets external to a development or from internal collector or arterial roads, at least four of the following elements must comprise 15 percent of façade length for facades longer than 150 feet:
1. Parapets.
2. Cornices.
3. Roofline offsets.
4. Windows or doors.
5. Window hoods.
6. Transoms.
7. Bulkheads.
8. Awnings or canopies.
9. Ribs or columns.
10. Changes in texture or masonry.
(d) Project entry. Primary building entrances shall be clearly defined and shall be recessed or framed by a sheltering element such as an awning, arcade, overhangs, or portico (in order to provide weather protection for pedestrians). Public entrances flush with the building wall with no cover are not allowed.
(e) Landscape entrance. For industrial subdivisions, the primary vehicular entrance to the project should be clearly defined and provide adequate sight distance for vehicles and pedestrians. The entrance shall be designed as a special statement reflective of the character and scale of the development to establish identity for tenants, visitors, and patrons. Landscape design at the subdivision entrance shall complement any special landscape treatment at intersections of arterial and collector roads or local roads that intersect with arterial/collector roads with common elements. Flowering accent plantings and specimen trees shall be used to reinforce the entry statement. Planting design should have focal points at the subdivision entrance and other areas of interest using distinct planting and/or landscape features.
Exhibit 807: Sample Illustrations of Design Features for Industrial Development
(f) Windows and openings.
(1) All windows and doors at the ground floor level on any retail building shall be transparent.
(2) Large areas of glass shall be recessed in shadow or otherwise contrast with the building façade.
(3) Large, glazed areas shall be divided into smaller parts by using mullions to express individual windows or groupings of windows.
(g) Sign regulations. In addition to complying with the general and specific sign standards in article VI, development shall comply with the sign standards for the applicable character area identified in the CRC design guidelines. Billboards, where permitted, are not subject to the CRC design guidelines.
(h) Lighting. Outdoor area lighting shall be provided as required in article VI. Such lighting shall be shielded to direct light downward and not into dwelling units adjacent to the commercial development.
Lighting shall be provided to illuminate the intersections of primary interior driveways and building entryways. Lighting fixtures shall comply with the character areas standards identified in the CRC design standards.
(i) Electrical and service equipment. HVAC and similar types of incidental machinery or equipment trash receptacles, dumpsters, utility meters, above-ground tanks, satellite dishes and antennas shall be screened from view from public streets that are external to the development project, internal collector or arterial streets, abutting residential zoning districts, and public parks.
(j) Internal and external compatibility. Buildings that are visible from streets abutting the development, from internal collector and arterial streets or from adjacent residential zoning districts shall have compatible scales, bulk, heights, architectural styles, and roof styles. Development shall use a combination of plantings, buffers and building design to ensure compatibility with adjacent development.
(Ord. No. 06-2020, § 3, 12-8-2020; Ord. No. 2022-15, § 2, 10-11-2022) Secs. 114-808—114-899. Reserved.
ARTICLE IX. ENVIRONMENTAL MANAGEMENT
This article includes standards for or references to county standards for flood damage prevention, stormwater management and related provisions.
Sec. 114-900. Flood damage prevention ordinance.
All development shall comply with the provisions of the flood damage prevention provisions of subpart B, chapter 105 of the Bryan County Code of Ordinances and any other state or federal laws relating to flooding and flood management. All final plats must show the limits of flood zones and contain all appropriate references relating to special flood hazard areas (SFHA) required by the County Ordinances, FEMA, and all other applicable state and federal laws.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-901. Soil erosion and sedimentation control.
All development shall comply with the provisions of the soil erosion and sedimentation control provisions of subpart B, chapter 111 of the Bryan County Code of Ordinances and any other state or federal laws relating to soil erosion and sedimentation control, including related provisions of this UDO.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-902. Stormwater management.
(a) Development requiring subdivision or site plan approvals are subject to the provisions of this section and applicable standards of the Engineering Design Manual.
(b) Prior to approval of construction plans or a site plan, a certificate from the applicant's engineer stating that the proposed development will meet or exceed all applicable requirements for stormwater management in accordance with the Engineering Design Manual and that no detrimental impacts will be imposed on any adjacent and/or downstream properties as a result of the project shall be submitted.
(c) Each site plan and subdivision shall incorporate stormwater management facilities sufficient to reduce pre-development peak discharge rates across adjacent property lines. The Stormwater Management Report (Drainage Study) shall specifically analyze the discharge point(s) for pre and post stormwater runoff for the proposed development.
(d) No subdivision or site plan development shall be undertaken unless the applicant can establish to the engineering director that the flood potential within the subdivision, on adjacent or surrounding lands or wetlands will not be increased by the development of such subdivision. If such potential is in question, the engineering director shall make the final determination.
(e) Inter-basin transfer of water between river basins is prohibited.
(f) All applications for site plan approval shall include a map at appropriate scale of all site areas to be covered by impervious surfaces and calculations of said areas. Any change to [an] impervious surface after approval by the engineering director will require updated maps and the approval of the engineering director.
(g) All roadside drainage features shall be piped, including such features as ditches, swales, streams, and canals, unless otherwise allowed by this UDO.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-903. Green infrastructure.
(a) Applicability.
(1) All new development or substantial redevelopment of a site accommodating multi-family residential, residential recreation, commercial, institutional, or industrial uses shall provide green infrastructure to manage stormwater runoff on site as identified in this section or the Georgia Coastal Stormwater Supplement, whichever standards are more stringent. Substantial redevelopment includes:
a. Improvements with a cost exceeding 50 percent of the building's assessed value;
b. Increases in impervious coverage on a site that exceed the greater of ten percent of the existing impervious cover or 2,500 square feet of impervious cover; or
c. Resurfacing or modification of the hardscape of a parking lot other than restriping.
(2) All new development or substantial redevelopment shall prepare and submit a drainage report/stormwater management plan together with the site plan submittal. This requirement does not apply to development of a single family or duplex lot.
a. A minimum of 50 percent of the site's required landscaping area, as required by this code, shall consist of green infrastructure.
b. Hardscape, including but not limited to parking spaces, drive aisles, walkways, outdoor vehicular storage areas, and gathering spaces are encouraged to be surfaced with pervious paving where feasible.
(b) Green infrastructure types.
(1) Green infrastructure (GI) for planting areas includes:
a. Bioswales;
b. Bioretention cells;
c. Constructed wetlands;
d. Dry detention basins;
e. Stormwater planters; and
f. Green roofs.
(2) Green infrastructure that does not require planting includes:
a. Infiltration Trenches;
b. Cisterns and underground stormwater chambers, constructed for detention;
c. Retention ponds.
(3) Design and construction of hardscape surfaces, including but not limited to parking spaces, drive aisles, walkways, and gathering spaces with pervious paving.
(4) Alternative green infrastructure designs that the engineering director determines will safely and efficiently manage stormwater.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-904. Lakes, ponds and waterways.
(a) Artificial or natural waterways, lakes, or ponds for recreation shall not be accepted for maintenance by the county.
(b) Waterways, lakes, and ponds shall be maintained by either an established homeowners' association or individual property owner(s). In either case, the final plat must indicate who will be responsible for maintenance. Detention and retention basins shall be maintained by a homeowners' association. The county will not accept maintenance of drainage basins.
(c) Private maintenance provisions must be made to the satisfaction of the engineering director. The developer is not allowed to be designated as the responsible provider of maintenance.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-905. Compliance with laws relating to rivers, streams or marshlands.
Subdivisions abutting rivers or streams shall comply with all laws relating to the development of land adjacent to rivers, streams, or marshlands.
(Ord. No. 06-2020, § 3, 12-8-2020) Secs. 114-906—114-999. Reserved.
ARTICLE X. ROADS AND PEDESTRIAN WAYS
This article includes general design standards for development of improvements for roads and pedestrian facilities.
Sec. 114-1000. Current road inventory.
Appendix E is hereby adopted as the current county road inventory. Any additional roads added or removed to this inventory must be done in compliance with the requirements of this UDO and state law.
The engineering director and GIS Coordinator shall maintain the road inventory, including approved road names and route numbers, and shall update the road inventory within 45 days of the dedication, approval, or abandonment of a road from the county inventory. The engineering director shall present the current road inventory annually for the board of commissioners to review and adopt.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-1001. Road layout and construction.
All roads to be constructed in a subdivision, residential or non-residential, must comply with the following provisions:
(a) General. Transportation system improvements should be designed to include bicycle and pedestrian facilities as part of the road or development to reduce automobile trip generations.
All roads and pedestrian ways must be designed and constructed in accordance with the requirements of this article and the Engineering Design Manual.
(b) County-maintained or approved private road. All roads must be either: (i) accepted by the board of commissioners as a county-maintained road; or (ii) designated and approved as an approved private road.
(c) Continuation of existing road pattern. The arrangement of roads in a subdivision shall provide for the alignment with, or the continuation of, or the appropriate projection of existing roads in surrounding areas.
(d) Road jogs. Road jogs or centerline offsets in the horizontal alignment of roads across intersections of less than 150 feet shall be prohibited.
(e) Intersections. The centerline of no more than two roads shall intersect at any one point. Roads shall be laid out so as to intersect as nearly as possible at right angles and no roads shall intersect any other road at less than 75 degrees. Curbed roads shall have a minimum tangent of 100 feet at intersections.
(f) Subdivisions on arterial roads. Where a subdivision abuts or contains an existing or proposed arterial road, the board of commissioners may require local roads, traffic calming measures, or other measures necessary to discourage excess traffic through residential subdivisions.
(g) Permanent dead-end roads. Dead-end roads, designed to be such permanently, except cul-de-sacs built pursuant to section 114-1005, shall be provided at the closed end with a turn-around having an outside roadway diameter of not less than 100 feet, and a right-of-way diameter of not less than 120 feet.
(h) Temporary dead-end roads. Temporary dead-end roads shall only be allowed in connection with phased construction of subdivisions within a development according to an approved sketch plat or development plan.
(i) Road names. Proposed road names for new roads shall be submitted to 911 for review and approval. If 911 disapproves a proposed road name, the applicant must submit another proposed road name.
(j) Road name markers. Road name markers, which shall be constructed to county specifications, shall be installed at all road intersections.
(k) Paving. All roads must be paved, except those roads exempt from paving pursuant to article IV, division 1.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-1002. DOT approval.
For subdivisions abutting a road maintained by the State of Georgia, DOT approval must be obtained for such subdivision's plan for access or improvement to such road.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-1003. Road design standards.
(a) Residential roads. Roads primarily serving residential development shall comply with the standards in Exhibit 1002a.
Exhibit 1002a: Residential Road Design Standards Road Type: Local Roads
• Right-of-Way Minimum: 60 feet
• Road Width: 27 feet from back of curb to back of curb
• Travel Lane Width: 12 feet
• Curb and Gutter Width: 1.5 feet
• Planting Strips: 4-6 feet in width, depending on plantings, on both sides of the road with street trees planted in the strip between the pavement and sidewalks. Root barriers shall be installed pursuant to section 114-633
• Sidewalks: 5 feet in width on both sides of the road Road Type: Collector Roads: with Sidewalks without On-Street Parking
• Right-of-Way Minimum: 60 feet
• Travel Lane Width: 12 feet
• Shoulder Width (with no curb): 2 feet
• Curb and Gutter Width: 1.5 feet
• Bicycle Lane Width: 5 feet
• Planting Strips Minimum: 6 feet in width on both sides of the road with street trees planted in the strip between the pavement and sidewalks. Root barriers shall be installed pursuant to section 114- 633
• Sidewalks: 5 feet in width on both sides of the road Road Type: Collector Roads: with Sidewalks with On-Street Parking
• Right-of-Way Width Minimum: 80 feet
• Travel Lane Width: 12 feet
• Shoulder Width (no curb): 2 feet
• Curb and Gutter Width: 1.5 feet
• Bicycle Lane Width: 5 feet
• Vehicular Parking Lane Width: 9 feet
• Planting Strip Width: 6 feet in width on both sides of the road with street trees planted in the strip between the pavement and sidewalks. Root barriers shall be installed pursuant to section 114-633
• Sidewalks: 5 feet in width on both sides of the road
(b) Non-residential roads. Roads within commercial or industrial districts shall comply with the standards in Exhibit 1002b.
Exhibit 1002b: Non-Residential General Road Design Standards Road Type: Non-Residential Local Roads
• Right-of-Way Width Minimum: 80 feet
• Road Width: 30 feet
• Travel Lane Width: 15 feet
• Vehicular Parking Lane Width: 9 feet
• Curb and Gutter Width: 1.5 feet
• Planting Strip Width: 6 feet in width on both sides of the road with street trees planted in the strip between the pavement and sidewalks. Root barriers shall be installed pursuant to section 114-633
• Sidewalks: 5 feet in width on both sides of the road Road Type: Non-Residential Collector Roads
• Right-of-Way Width Minimum: 100 feet
• Travel Lane Width: 15 feet
• Median Width: 15 feet
• Curb and Gutter Width: 1.5 feet
• Bicycle Lane Width: 5 feet
• Vehicular Parking Lane Width: 9 feet
• Planting Strip Width: 6 feet in width on both sides of the road with street trees planted in the strip between the pavement and sidewalks. Root barriers shall be installed pursuant to Section 114-633
• Sidewalks: 5 feet in width on both sides of the road
• Utility Easements: 20 feet on both sides of the road
(c) Roads without curbs and gutters. Subject to the approval of the engineering director, in the A-5, RR-2.5, and RR-1.5 zoning districts, roads serving single-family residential development may be provided without curbs and gutters subject to the standards in Exhibit 1002c. In the RR-1 zoning district, the board of commissioners may approve roads without curb and gutter through the sketch plat process. In the I-2 district, the engineering Director may approve roads serving industrial development to be constructed without curbs and gutters subject to the standards in the Exhibit 1002d. Stormwater management and drainage requirements must be met. An applicant may request the sidewalk require-ment be waived during sketch plat application review and approval process and is subject to Board of Commissioner approval. Drainage swales shall be designed and constructed as required. Drainage easements shall be provided as necessary.
Exhibit 1002c: Residential Roads Design Standards without Curbs and Gutters Road Type: Local Roads with Sidewalks and without Curbs and Gutters
• Right-of-Way Width Minimum: 60 feet
• Road Width: 28 feet
• Travel Lane Width: 12 feet
• Shoulder Width: 2 feet
• Planting Strip Width: 6 feet in width on both sides of the road with street trees planted in the strip between the pavement and sidewalks. Root barriers shall be installed pursuant to section 114-633
• Sidewalks: 5 feet in width on both sides of the road Exhibit 1002d - Industrial Roads Design Standards without Curbs and Gutters Road Type: Industrial Roads with Sidewalks and without Curbs and Gutters
• Right-of-Way Width Minimum: 100 feet
• Travel Lane Width Minimum: 15 feet
• Turn Lane/Median Width Minimum: 15 feet
• Planting Strip Width: 6 feet in width on both sides of the road with street trees planted in the strip between the pavement and sidewalks. Root barriers shall be installed pursuant to Section 114-633
• Sidewalks: 5 feet in width on both sides of the road
• Utility easements: 20 feet on both sides of the road (Ord. No. 06-2020, § 3, 12-8-2020; Ord. No. 19-2021, § 2, 9-14-2021) Sec. 114-1004. Guidelines for determining when additional right-of-way is needed for collector and arterial roads.
When a traffic impact assessment prepared pursuant to section 114-428 projects the average daily traffic volume will exceed 2,500 vehicles per day, the engineering director may recommend to the board of commissioners, and the board of commissioners may require greater pavement or right-of-way width than required under section 114-1003.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-1005. Cul-de-sac design.
(a) Cul-de-sac roads shall not exceed 600 feet in length and shall be designed as a local road with a 50 foot radius bulb and a fourty-foot radius travelway.
(b) Local roads exceeding 600 feet in length are classified as dead end roads and shall have a permanent turn-around right-of-way with a 60 foot radius bulb and a 50 foot radius travelway. The length of such road shall be measured from the point of intersection of the centerline of the intersecting road and the cul-de-sac to the center point of the cul-de-sac turn-around.
(c) The engineering director may approve alternative designs for the ends of cul-de-sac roads that do not exceed 300 feet in length.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-1006. Additional lanes for commercial and industrial districts.
Roads in commercial and industrial zoning districts may be required to have at least two lanes in each direction or a center turn lane depending on the findings in the approved Traffic Impact Analysis, except that the engineering director may require additional lanes in order to make provisions for service access, such as off-street loading, unloading, and parking consistent with and adequate for the uses proposed.
All lanes must be designed and constructed in accordance with this UDO, the Engineering Design Manual, GDOT, AASHTO, and MUTCD standards.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-1007. Additional right-of-way.
A proposed subdivision that includes a road that does not conform to the minimum right-of-way requirements of section 114-1003 shall provide for additional right-of-way along either one or both sides of said road so that the minimum right-of-way required by this UDO can be established. If the proposed subdivision abuts only one side of said road, then a minimum of one-half of the required extra right-of-way shall be required.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-1008. Sight triangles.
To prevent traffic hazards from limited visibility at a street intersection or intersection of a road and driveway, no structure, building, earthen bank, sign or vegetation shall be allowed within the sight triangle on corner lots if it exceeds two and one-half feet in height, measured from grade at the finished, paved area at the center of the roadway. The sight triangle as defined in section 114-1304 shall be designed in accordance with GDOT and AASHTO standards based on geometry and speed limits.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-1009. Pedestrian ways.
Pedestrian ways shall be required for new road construction as identified in Exhibits 1002(a) and (b) and for new development as identified below. Pedestrian ways must be designed and constructed in accordance with the Engineering Design Manual requirements. Additionally, the following standards apply:
(a) Where sidewalks are situated within public or private rights-of-way/easements, the following standards generally apply for residential and non-residential roads:
(1) The location of the pedestrian ways shall be placed five feet inside the right-of-way or as otherwise approved by the engineering director and in a logical terminus and with wheelchair access.
(2) Sidewalks shall be four inches thick, broom-finished, Portland cement concrete constructed on a firm sand or rock subgrade. For sidewalks within non-residential subdivision, thickness shall be determined by the applicant's engineer to accommodate the use at the location of the feature.
(3) The cross slope shall not be less than one-fourth inch per foot.
(b) Where multi-use paths located within developments or provide connection between developments.
(1) Any such multi-use shall be restricted as part of a subdivision common open space when on a residential site; on a non-residential site, a permanent easement shall be reserved and maintenance assigned to a specific entity.
(2) Choice of surface materials include concrete, bituminous mixes, soil cement, stabilized earth, treated wood planking, and pavers, and shall depend upon use and users of the pedestrian way and its relationship to other amenities. Other material may be approved by the engineering director depending on the location and ability to be relatively maintenance free.
(3) Multi-use paths shall be a minimum of ten feet in width.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-1010. Bikeways and bicycle lanes.
(a) If provided by the applicant, bikeways may be sized on the probable volume of bicycle traffic, and in consideration of the site's location in relation to other populated areas. Bikeways shall be minimum of eight feet paved width provided for two-way bicycle traffic and a five feet paved width for one-way bicycle traffic.
(b) If provided by the applicant, bicycle lanes shall be at least five feet wide, or wide enough to allow safe passage of bicycles and motorists
(c) Bikeway or bicycle lanes may be required along the road frontage of the development or subdivision if the community development and engineering directors determine the county comprehensive plan, capital improvement plan or if adopted, pedestrian and bicycle plan, identify the location as a future multi-modal corridor.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-1011. Subdivision and multi-family entrances and driveways.
(a) Entrances and driveways to subdivisions shall be designed and constructed in accordance with the Engineering Design Manual and the provisions of this section.
(b) Entrances and driveways to subdivisions abutting state and federal roads shall also be designed and constructed in accordance with all applicable laws, including, but not limited to, the rules and regulations of the Georgia Department of Transportation.
(c) When driveways and entrances are limited under this section, the approved locations of such driveways and entrances shall be shown on the final plat.
(d) All subdivisions of 30 or more lots shall provide at least one entrance to the subdivision that includes an entry drive of at least 120 feet in depth measured from the right-of-way of the street that the entry street intersects. Along the required entry drive, there shall be no driveways and all abutting lots shall be screened from view through a combination of walls, berms and plantings. The entrance shall include at least two of the following features:
(1) A divided roadway with a landscaped median island;
(2) Alternative paving material such as brick or natural stone;
(3) Fountain or other water feature;
(4) Sculpture or public art;
(5) Prominent plantings that exceed minimum requirements for streetscape buffers [define]; or
(6) Gatehouse, gazebo, clock tower or similar structure.
(e) A description of and design specifications for proposed entranceway features shall be provided at the time of submission of the sketch plat. Maintenance of the subdivision entry features shall be provided by a homeowners' association and the applicant shall provide documentation establishing legal and financial responsibility for all entryway features in a form approved by the county attorney.
Additional right-of-way may be required to accommodate entranceway features. The design and location of proposed features within or adjacent to public street rights-of-way shall be approved by the engineering director.
(f) All subdivision entries shall include ground-mounted signs with the subdivision name constructed of brick, rock, or other textured masonry. The community development director may approve a brick, rock, or other textured masonry wall with the subdivision name in lieu of a monument sign. This requirement applies to subdivisions with 30 lots or more.
(g) Multi-family developments shall meet the following requirements:
(1) Entrances shall have a ground mounted signs with the development's name constructed of brick, rock, or other textured masonry.
(2) For development with 30 or more dwelling units, a divided ingress-egress driveway with a landscaped median for all entrances from public streets shall be provided.
(3) All proposed drives shall be improved in accordance with the Engineering Design Manual.
(Ord. No. 06-2020, § 3, 12-8-2020) Sec. 114-1012. Private roads—Major subdivisions.
Private roads within major subdivisions shall comply with the standards contained in this section.
Private roads associated with minor subdivisions are addressed in section 114-406.
(a) The board of commissioners may approve private roads subject to the provisions of this section.
Read this code where it is posted (Municode) The source is the county's code as its publisher or its own website posts it. Check it there for later changes.