The following criteria shall apply in significant recharge areas as identified in Hydrologic Atlas 18 (1989 edition) within the unincorporated area of the county: (1) New above-ground chemical or petroleum storage tanks, having a minimum volume of 660 gallons, shall have secondary containment for 110 percent of the volume of such tanks or 110 percent of the volume of the largest tank in a cluster of tanks. Such tanks used for agricultural purposes are exempt from this requirement, provided they comply with all federal requirements. (2) New agricultural waste impoundment sites shall be lined if they are within: a. A high pollution susceptibility area; b. A medium pollution susceptibility area and exceed 15 acre-feet in size; or c. A low pollution susceptibility area and exceed 50 acre-feet in size. As a minimum, the liner shall be constructed of compacted clay having a thickness of one-foot and a vertical hydraulic conductivity of less than 5 × 10-7 cm/sec or other criteria established by the natural resource conservation service. (3) New homes served by septic tank/drain field systems shall be on lots having the following minimum size limitations as identified on table MT-1 of the department of human resources' Manual for On-Site Sewage Management Systems ("DHR table MT-1"): a. 150 percent of the subdivision minimum lot size of DHR table MT-1 if they are within a high pollution susceptibility area; b. 125 percent of the subdivision minimum lot size of DHR table MT-1 if they are within a medium pollution susceptibility area; and c. 110 percent of the subdivision minimum lot size of DHR table MT-1 if they are within a low pollution susceptibility area. Any lot of record on the date of the adoption of the ordinance from which this section derives (July 6, 1999) shall be exempt from the minimum lot size requirements of this subsection. Any conflict between the minimum lot size requirements of this subsection and the minimum lot size requirements of the county zoning ordinance shall be resolved in favor of the provision that establishes the larger minimum lot size. (4) New mobile home parks served by septic tank/drain field systems shall have lots or spaces having the following minimum size limitations as identified on table MT-2 of the department of human resources' Manual for On-Site Sewage Management Systems ("DHR table MT-2"): a. 150 percent of the subdivision minimum lot or space size of DHR table MT-2 if they are within a high pollution susceptibility area; b. 125 percent of the subdivision minimum lot or space size of DHR table MT-2 if they are within a medium pollution susceptibility area; and c. 110 percent of the subdivision minimum lot or space size of DHR table MT-2 if they are within a low pollution susceptibility area. Any lot of record on the date of the adoption of the ordinance from which this section derives (July 6, 1999) shall be exempt from the minimum lot size requirements of this subsection. Any conflict between the minimum lot size requirements of this subsection and the minimum lot size requirements of the county zoning ordinance shall be resolved in favor of the provision that establishes the larger minimum lot size. (5) No construction may proceed on a building or mobile home to be served by a septic tank unless the county health department first approves the proposed septic tank installation as meeting the standards of the DHR manual and minimum lot size requirements. (6) New facilities which handle hazardous materials of the types listed in section 312 of the Resource Conservation and Recovery Act of 1976 (excluding underground storage tanks) and in amounts of 10,000 pounds or more on any one day shall perform their operations on impervious surfaces and in conformance with any applicable federal spill prevention requirements and any local fire prevention code requirements. (7) Permanent storm water infiltration basins shall not be constructed in areas having high pollution susceptibility.