The schedules below shall be followed for the design of subdivision plats and general development plans for planned developments.
Schedule 7.7.1: Intersection Design Standards Approach Speed at Intersections Within Subdivision Maximum Approach Speed
(mph) 25 Geometrics Vertical alignment with intersection Crown on level terrain (flat grade); a leveling area shall be provided having not greater than two per cent rate at a distance of 60 feet, measured from the nearest right-of-way line of the intersecting street.
Minimum angle of intersection streets 90 degrees with a minimum 100-foot long throat.
Sight distance at intersections Intersection sight distance shall be the design value as determined by AASHTO's A Policy on Geometric Design of Highways and Streets (Green Book).
Functional Class Minimum Curb or Pavement Edge Radius (ft) Minimum Centerline Offset of Adjacent Intersection (ft) Local or marginal access to local 20 125 Local or marginal access to collector 25 440 Collector to collector 30 660 Collector, marginal access to arterial 40 1,320 Schedule 7.7.2: Cul-de-sac Street Design Standards Cul-de-sac
Street Type Maximum Length of Street without Traffic Calming Measures Maximum Length of Street with Approved Traffic Calming Design(1) Roadway Right-ofWay Diameter(2) Permanent 800 linear feet 1,200 linear feet 60' Temporary (permitted as a segment of a continuous street only) 1,000 linear feet 1,400 linear feet 60'
(1) Approval by the county engineer.
(2) In turnaround area of cul-de-sac, pavement shall be 80-foot diameter with a right-of-way diameter of 120 feet.
Schedule 7.7.3: Right-of-Way Design Standards—Curb and Gutter (flexibility regarding curb type shall be permitted as long as it accommodates the system of drainage proposed)
Functional Class Lanes Pavement Width (in feet) Right-of-Way Width (in feet) Marginal access Two lanes 20 50 Local Two lanes 20 50 Two lanes with parallel parking one side of street 30 50 Collector Two lanes 20 60 Two with left turn lane 30 60 Two with left turn and service lane 40 60 Four lane 48 80 Four lane with service lanes 78 90 Arterial Two lanes 24 60 Four lane 48 80 Four lane with service lane 64 100 Four with left turn lane 68 100 Four with left turn lane and service lane 86 100 Schedule 7.7.4: Right-of-Way Design Standards—Unpaved Shoulder with Open Channels
(drainage swales may be used when it can be shown that soil or topography make their use favorable and where it is in the best interest of the community to preserve its rural character by using drainage swales)
Functional Class Lanes Pavement Width (in feet) Shoulder Width (in feet) Ditch Slope Ratio (front and back) Right-ofWay Width (in feet) Marginal access Two 20 4 3:1 50 Local Two 20 4 3:1 60 Two with cul-de-sac 60 4 3:1 60(1) Collector and arterial Two 22 8 3:1 80 Four 44 10 3:1 100 Four with left turn lane 55 10 3:1 120
(1) In turnaround area of cul-de-sac, pavement shall be 80-foot diameter with a right-of-way diameter of 120 feet.
Schedule 7.7.5: Right-of-Way Design Standards—Inverted Crown (may be used only for subdivisions with less than 20 lots; or planned developments where streets are not publicly dedicated)
Functional Class Lanes Pavement Width (in feet) Centipede Sodded Shoulder (in feet) Right-of-Way Width (in feet) Marginal access Two lanes 20 5 50 Local only Two 20 5 60 Cul-de-sac turnaround area 80' diameter 5 120' diameter Schedule 7.7.6: Alignments Standards Minimum Sight Distance at Vertical Curves Functional Class Design Speed
(MPH)
Minimum Curve Radii (in feet) Minimum Stopping Sight Distance (in feet) Local 30 275 200 Collector 50 350 350 Arterial Determined by AASHTO Minimum Radii of Centerline Curvature at Horizontal Curves Functional
Class Design Speed (MPH) Minimum Curve Radii (in feet) Marginal
access 25 100 Local 30 275(1) Collector 35 390 Arterial Determined by Georgia DOT standards Tangents between Reverse Curves Functional Class Design Speed (MPH) Minimum Curve Radii (in feet) Marginal
access 25 50 Local 30 100 Collector 35 100 Arterial Determined by Georgia DOT standards
(1) For horizontal curves, the centerline radius of curvature shall not be less than 275 feet on local roads unless the topography of the land to be subdivided makes this impractical.
Schedule 7.7.7: Standard Grades for Streets and Roadside Drainage Minimum Curb
Radius (ft) Street (maximum) Roadside Ditches (minimum) Marginal access 6.0% 0.5% Local 6.0% 0.5% Collector 6.0% 0.5% Arterial Determined by Georgia DOT standards Schedule 7.7.8: Pedestrian Way Design Standards Type of Development or Pedestrian Way Location Minimum Width (in feet) Thickness (in inches) Materials and Strength Slope Subdivision Right-of-way 5' + 3' median 4 Portland cement concrete 28 day strength of 2,800 psi " per foot maximum Planned development Right-of-way 5' + 3' median 4 Walking trail Permanent private easement 6 2 Bituminous mixes, soil cement, stabilized earth, treated wood planking, and pavers Approved by the county engineer Crosswalks Intersections 8 NA White, reflective Meeting ADA standards
Schedule 7.7.9(a): Minimum Number of Public Access Points to a Public Street Development Type and Intensity
Minimum Number(1) Public Access by Functional Classification Residential, 120 units or less 1 Paved: Local Residential, 121—239 units 2 Paved: Local, Collector Residential, 240—400 3 Paved: Local, Collector, Arterial Residential, 401 or more 4 + 1 per 120
additional lots Paved: Local, Collector, Arterial Nonresidential, 50 parking spaces or less 1 Paved: Local, Collector, Arterial Nonresidential, 51 parking spaces or more 2 Paved: Local, Collector, Arterial Schedule 7.7.9(b): Separation of Access Points for Streets and Driveways Posted Speed Limit of Road Minimum Spacing(1)
35 mph or less 110 feet 36—45 mph 230 feet 45—54 mph 330 feet 55 mph or more 440 feet
(1) The county engineer and zoning administrator may jointly grant an administrative variance to reduce or increase the minimum requirements for access points and spacing that adequately addresses the public health, safety and welfare, unless there are more restrictive requirements by a state or federal agency.
Schedule 7.7.10: Community Water System Standards Element Specification
Water system:
minimum flow Minimum flow standards shall be no less than 500 gallons per minute, while sustaining a 20-psi residual pressure, for a period of two hours at the furthermost point from the available water source(s). A proof of flow test, in accordance with NFPA 291, shall be provided to the fire chief, and annual flow test records for the water system.
Water system:
service lines Subject to design requirements approved by the Georgia EPD. Water system distribution lines when located in the right-of-way, shall be installed to have a minimum depth of 24 inches of continuous and uniform bedding. Water system distribution lines shall be installed to have a minimum depth of 36 inches if located under any proposed new street. Service lines must be stubbed out to the property line to serve each lot before the street is surfaced.
Fire protection, hydrants Fire hydrants shall be no further than 1,000 feet apart measured along an improved surface navigable by a fire apparatus.
Well sites: lot layout Wells sites should be of sufficient size to accommodate and adequately maintain the well and storage tank. Wells shall be established on separate lots of record that shall be a minimum of 50 feet in depth and 50 feet in width. The minimum area of such lots shall be 2,500 square feet. The well shall be located no closer than 50 feet to any exterior property line of the subdivision. Activities permitted on such lots shall be limited to those activities related to construction, operation, or maintenance of a well. Such lots shall be established only with direct access onto a public street or be served by an approved private vehicular access easement not less than 20 feet in width.
History
(Ord. of 11-4-97, § 7.5; Amd. of 4-4-23(1); Amd. of 12-17-24)