Connection of a building sewer into the public sewer shall be made at the wye branch, if such branch is available at a suitable location. If the public sewer is 12 inches in diameter, or less, and a wye is not available, the authority shall, at the expense of the owner, install a wye branch in the public sewer at the location determined by the authority. When the public sewer is greater than 12 inches in diameter, and no approved wye branch is available, the authority shall, at the expense of the owner, cut a hole into the public sewer, with entry in the downstream direction at an angle of about 45 degrees, and install a 45-degree bend with the spigot end cut so as not to extend past the inner surface of the public sewer. The invert of the building sewer at the point of connection shall be at the same or at a higher elevation than the invert of the public sewer. A smooth, neat joint shall be made, and the connection made secure and watertight by encasement in concrete. Special fittings may be used for the connection only when approved by the authority.