Every subdivider at his own expense shall be required to install, or at his own expense to have installed by the appropriate public utility the following improvements:

(1) Streets and related improvements.

a. Street grading. All street rights-of-way shall be cleared and graded to the standards of the county. These standards and other standards of the county referred to in these regulations are on file in the offices of the public works department, the county water authority, the environmental health department, the soil conservation service, and the community development department.

b. Street paving.

1. Roadways, constructed in each subdivision or used as a required subdivision entrance, shall be paved according to the standards adopted by the county in place at the time the subdivision is built.

2. Street paving widths shall be in conformance with standards set forth in article V.

c. Curbs and gutters.

1. Curbs and gutters shall be installed on all new subdivision streets in accordance with standards adopted by the county.

2. Curbs and gutters shall be two in width and of rollback or L-back construction.

3. Design and installation of curbs and gutters shall be in accordance with the public works department standards.

d. Street trees. Street trees and other shrubbery that may be retained or planted shall be placed or retained so as not to obstruct sight distances at street intersections.

(2) Project access improvements. When property that abuts upon an existing or proposed county road that is to be developed or redeveloped as a single family residential or duplex subdivision, multi-family or nonresidential development and the county road will provide access to the property, the following access improvements to the county road (deceleration lanes, turn lanes, etc.) shall be provided by the developer as required:

a. A deceleration lane shall be required at each project driveway or subdivision street entrance, which provides street access. In the event a street has an existing or proposed median, and the developer desires to construct a median break to serve the development, a left turn lane leading to the median break shall be required by the developer and shall meet the latest standards of the county.

b. Deceleration lanes shall have a length of 75 to 200 feet, with an additional 50-foot taper length, a pavement width of 12 feet (exclusive of curb and gutter) and shall be provided with curb and gutter. Additional right-of-way to accommodate the deceleration lane and an 11-foot shoulder shall be dedicated by the developer to the county at no cost. Associated drainage improvements as deemed necessary by the construction of the deceleration lane shall also be required.

c. Other project access improvements may be required by the county in order to ensure adequate site access, pedestrian access, convenience and safety to the motoring public.

d. The developer shall be responsible for the relocation of public or private utilities and drainage structures, as may be occasioned by the required project access improvements.

e. If the project driveway referred to in subsections (2)a. and b. above is to be used exclusively for one-single family residence and is not part of a larger development, the director may, in his discretion, waive the requirement for a deceleration lane where all sight distance requirements herein and other safety concerns are satisfied.

(3) Water supply.

a. If, in the opinion of the county water authority, an adequate public water supply is within 1,000 feet of the subdivision, the subdivider shall install or have installed a system of water mains and connections to each lot which shall be in accordance with adopted standards of the county water authority.

b. Where a public water supply is not available, each lot in a subdivision shall be furnished with a water supply system approved by the Environmental health department, if such system consists of separate wells located on and serving individual lots; and any other non-public water supply system shall be approved by the county water authority and the department of natural resources EPD drinking water division.

(4) Sanitary sewage disposal.

(5) Storm drainage. Every subdivision shall be served by storm drainage facilities such as drains, sewers, catch basins, culverts, detention areas, and other facilities as provided in article VII.

(6) Monuments. Permanent monuments shall be accurately set and established:

a. Where plat boundary lines intersect with land lot lines.

b. Permanent bench markers shall be placed at all land lot corners on the property being developed. These markers shall be concrete with brass marking. Placement (to be verified by the department's visual inspection) shall extend no less than six inches above the finished grade.

c. All corners shall be marked with an iron rebar or pin, at least 1 /2 inches in

diameter and 18 inches long driven so as to extend no less than one inch above finished grade.

d. The accurate location, material, and size of all existing monuments shall be shown on the final plat, as well as the future location of monuments to be placed after street improvements have been completed.

(7) Fire hydrants. Fire hydrants are required in compliance with the following development standards:

a. Minimum size water mains and spacing of fire hydrants.

1. In single-family residential subdivisions sufficient size water mains shall be installed to provide adequate flow in accordance with the current edition of the Georgia State Minimum Standard Fire Prevention Code in its entirety, including any applicable appendices. Fire hydrants shall be spaced not to exceed 500 feet. Three-way fire hydrants shall be used.

2. For multi-family residential dwellings or multi-family apartment complexes, industrial or commercial areas, to include motels, hotels, nursing homes, hospitals, education buildings, all office buildings and churches, sufficient size water mains shall be installed to provide adequate flow in accordance with the current edition of the Georgia State Minimum Standard Fire Prevention Code, latest edition, as adopted by the state, in its entirety including all applicable appendices. The fire chief may require larger mains and flows if the fire chief determines that the minimum standards will not adequately serve the use and occupancy of the structure(s). Fire hydrants shall be three-way hydrants and shall be spaced not to exceed 400 feet with additional hydrants located as necessary to permit all portions of buildings and combustible storage to be reached by hose lays of not more than 400 feet. Fire hydrant locations shall be approved by the fire chief or the chief's designee to allow firefighting equipment to be placed within 15 feet of said hydrants.

3. In mobile home parks and multifamily residential complexes, sufficient size water mains shall be installed to provide adequate flow in accordance with the current edition of the Georgia State Minimum Standard Fire Prevention Code, latest edition, as adopted by the state, in its entirety including all applicable appendices. Fire hydrants shall be spaced not to exceed 500 feet.

Three-way fire hydrants shall be used.

4. Prior to any preliminary plat being approved by the engineer, the fire chief or the fire chief's designee shall review, and if the standards are satisfied he will approve, the spacing of the fire hydrants, main size and water flows.

b. Installation.

1. Water mains and fire hydrants shall be installed and shall be under water pressure and ready for firefighting before any sheeting may be installed on walls and roofs of buildings other than fire-resistant construction.

2. All fire hydrants, fittings, valves and fire department connections shall be approved by the appropriate water provider or supplier and the fire department. Fire department connections shall not be less than 18 inches or more than 36 inches above the level of the adjoining ground or paving. The threads of such connections shall be uniform with that used by the fire department.

3. Fire hydrants shall meet the requirements of NFPA Standard 24, fire hydrants for outside protection, and shall have not less than six-inch connections with the mains. The number, size, and arrangement of the outlets, the size of the main valve opening and the size of the barrel shall be suitable for protection to be provided and shall be approved by the appropriate water provider having jurisdiction and the fire department.

Fire hydrants shall be placed no closer than 50 feet from the nearest building to be protected, except when approved otherwise by the fire chief or the fire chief's designee.

4. The size and shape of the operation nut, as well as the direction the hydrant stem operates, shall be established by the fire chief or his designee and be uniform with hydrants in the county water distribution system.

c. Private fire mains and hydrants.

1. Water mains on private property for fire protection purposes shall be designed and installed in accordance with public mains. Size of mains and water flows shall be adequate for the protection of the property served by said mains and in accordance with the Georgia State Minimum Standard Fire Prevention Code, latest edition, as adopted by the state, in its entirety including all applicable appendices. Hydrants shall meet local governing specifications and be located as required by the fire chief or the chief's designee.

2. Prior to installation, two sets of hydraulically engineered detailed plans, bearing a state-licensed sprinkler contractor's seal, shall be submitted to the fire department for approval. Before covering any installation, the fire chief or the chief's designee will perform an inspection to assure compliance with local governing authority requirements.

d. Effective January 1, 2006, the minimum fire flow for all buildings other than oneor two-family dwellings will be specified in Table B105.1 of the International Fire Code. A reduction in the required fire flow rate to a minimum of 1,000 gallons per minute may be allowed where the building or structure is equipped throughout with an approved automatic sprinkler system in accordance with chapter 9 of the International Fire Code. This subsection shall be in full force and effect until December 31, 2010, at which time it shall expire and be repealed in its entirety.

(8) Sidewalks. Sidewalks are optional improvements, but if installed, they must be built to the following standards:

a. Construction shall be four inches thick and 3,000-lb. mix concrete.

b. Compactions shall be a minimum of 95 percent.

c. Width of sidewalk may vary from four feet to six feet.

d. Sidewalks shall be so located that there will be a minimum of two feet of width between the outside edge of the curve and the leading edge of the sidewalk. There will be a minimum of a two inches fall in elevation from the outside edge of the curve to the back of the sidewalk, or vice versa, depending on drain slope.

e. All sidewalks and curb ramps at intersections shall meet the current rules and regulations established by the Americans with Disabilities Act.

(9) Removal of debris. To protect and preserve potential building sites, areas suitable for the installation of wells, septic tanks, and drain fields, and for other purposes, all stumps and other tree parts, brush, weeds, excess or scrap building materials, or other debris shall be removed from the subdivision site and disposed of in accordance with law. No tree stumps, or other portions of tree trucks or limbs shall be buried or burned anywhere in the development, except in accordance with county regulations. All dead or dying trees standing or fallen shall be removed from the site.

a. The department may approve exceptions to this prohibition on the burying or burning of debris provided that a specific plan and procedure for the burying or burning of debris are presented by the developer, approved by the department, and strictly adhered to by the developer.

b. The location(s) of any burial pits utilized on the site shall be identified on the final plat, and the accuracy of such identified locations shall be certified by the developer, rather than by the developer's engineer.

(10) Traffic control devices. Street name signs, traffic control signs, and devices such as striping and signalization, shall be provided by the subdivider through payment of specified fees to the public works department, or required signs and devices shall be installed by the subdivider in accordance with the requirements of, and subject to final approval by the public works department and subject to the following standards.

a. Signs.

1. Street name signs and stop signs shall be installed at all intersections within a development. All intersections shall contain a minimum of two street name signs and stop signs as appropriate for the intersection. Street name signs shall have a six-inch green background with four-inch white legends. Signs shall be mounted on three-lb., 12-foot green U-channel posts.

The installation of other styles of signs must be pre-approved by the director.

2. A "speed limit" sign shall be posted at each development entrance. Speed limits shall be set by the county or the state DOT.

3. A "Watch for Children" sign shall be posted at each subdivision entrance.

4. All required permanent signs shall be installed by the subdivider at no cost to the county. The subdivider shall install all street signs and traffic control devices prior to final plat approval.

5. The subdivider shall furnish and install all traffic control devices and street name signs prior to final plat approval.

b. Obstructing visibility at intersections. In accordance with subsection 86-125(c).

c. Procedure to be followed. The procedure to be followed by the subdivider in achieving compliance with these requirements shall be as directed by, and at the option of, the county.

d. Completion required prior to final plat. The installation/placement of all required permanent signs and traffic control devices shall be completed prior to final plat approval and/or the issuance of any building permit for any development within the subdivision.

e. Decorative signs allowable. The director, in his discretion, may allow decorative signs within a subdivision to the extent that state laws do not conflict placement thereof. Color, texture, and size shall be determined by the director. If a decorative sign and post installation is desired by the subdivider and approved by the county, the subdivider or homeowner's association shall be responsible for the installation and perpetual maintenance thereof. Failure to comply with maintenance requirements will result in the public works department taking over such maintenance with the installation of standard signs and post.

History

The history line the source prints at the end of the section.

(Ord. of 10-16-01, § 1; Res./Ord. of 10-21-03(2), § 1; Res./Ord. of 12-20-05)

Read this code where it is posted (Municode) The source is the county's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:carroll-county/code/86-161@2025-05-06-f2787cfe44

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Carroll County Code of Ordinances, Sec. 86-161. Generally | Georgia Commons