This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.7. ASME American Society of Mechanical Engineers Three Park Avenue New York, NY 10016-5990 Standard reference number Title Referenced in code section number A17.1/CSA B44—2007 Safety Code for Elevators and Escalators 606.1 ASTM ASTM International 100 Barr Harbor Drive West Conshohocken, PA 19428-2959 Standard reference number Title Referenced in code section number F 1346—91 (2003) Performance Specifications for Safety Covers and Labeling Requirements for All Covers for Swimming Pools, Spas and Hot Tubs 303.2 ICC International Code Council 500 New Jersey Avenue, NW 6th Floor Washington, DC 20001 Standard reference number Title Referenced in code section number IBC—12 International Building Code® 102.3, 201.3, 401.3, 702.3 IEBC—12 International Existing Building Code® 305.1.1, 306.1.1 IFC—12 International Fire Code® 201.3. 604.3.1.1, 604.3.2.1, 702.1, 702.2, 704.1, 704.2 IFGC—12 International Fuel Gas Code® 102.3 IMC—12 International Mechanical Code® 102.3, 201.3 IPC—12 International Plumbing Code® 201.3.505.1, 602.2, 602.3 IRC—12 International Residential Code® 201.3 IZC—12 International Zoning Code® 102.3, 201.3 NFPA National Fire Protection Association 1 Batterymarch Park Quincy, MA 02269 Standard reference number Title Referenced in code section number 25—11 Inspection, Testing and Maintenance of WaterBased Fire Protection Systems 704.1.1 70—11 National Electrical Code 102.4, 201.3, 604.2 APPENDIX A — BOARDING STANDARD The provisions contained in this appendix are not mandatory unless specifically referenced in the adopting ordinance. A101 — GENERAL A101.1 General. All windows and doors shall be boarded in an approved manner to prevent entry by unauthorized persons and shall be painted to correspond to the color of the existing structure. A102 — MATERIALS A102.1 Boarding sheet material. Boarding sheet material shall be minimum �-inch (12.7 mm) thick wood structural panels complying with the International Building Code. A102.2 Boarding framing material. Boarding framing material shall be minimum nominal 2-inch by 4-inch (51 mm by 102 mm) solid sawn lumber complying with the International Building Code. A102.3 Boarding fasteners. Boarding fasteners shall be minimum 3/8-inch (9.5 mm) diameter carriage bolts of such a length as required to penetrate the assembly and as required to adequately attach the washers and nuts. Washers and nuts shall comply with the International Building Code. A103 — INSTALLATION A103.1 Boarding installation. The boarding installation shall be in accordance with Figures A103.1(1) and A103.1(2) and Sections A103.2 through A103.5. A103.2 Boarding sheet material. The boarding sheet material shall be cut to fit the door or window opening neatly or shall be cut to provide an equal overlap at the perimeter of the door or window. A103.3 Windows. The window shall be opened to allow the carriage bolt to pass through or the window sash shall be removed and stored. The 2-inch by 4-inch (51 mm by 102 mm) strong back framing material shall be cut minimum 2 inches (51 mm) wider than the window opening and shall be placed on the inside of the window opening 6 inches minimum above the bottom and below the top of the window opening. The framing and boarding shall be predrilled. The assembly shall be aligned and the bolts, washers and nuts shall be installed and secured. A103.4 Door walls. The door opening shall be framed with minimum 2-inch by 4-inch (51 mm by 102 mm) framing material secured at the entire perimeter and vertical members at a maximum of 24 inches (610 mm) on center. Blocking shall also be secured at a maximum of 48 inches (1219 mm) on center vertically. Boarding sheet material shall be secured with screws and nails alternating every 6 inches (152 mm) on center. A103.5 Doors. Doors shall be secured by the same method as for windows or door openings. One door to the structure shall be available for authorized entry and shall be secured and locked in an approved manner. A104 — REFERENCED STANDARDS IBC—12 International Building Code A102.1, A102.2, A102.3 FIGURE A103.1(1) BOARDING OF DOOR OR WINDOW FIGURE A103.1(2) BOARDING OF DOOR WALL