--- title: Charlton County Code of Ordinances, Sec. 110-53. Effective collection: local-codes id: local-code:charlton-county/code/110-53 cite_as: Charlton County, Ga., Code of Ordinances § 110-53 canonical_url: https://georgiacommons.org/counties/charlton/code/110-53 md_url: https://georgiacommons.org/counties/charlton/code/110-53.md text_url: https://georgiacommons.org/counties/charlton/code/110-53/text source_url: https://library.municode.com/ga/charlton_county/codes/code_of_ordinances date: 2023-05-18 status: active jurisdiction: county:charlton jurisdiction_name: Charlton County county_fips: "13049" corpus_version: local-codes-charlton-county-4529f7e63a90 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/charlton/code/~part-ii/~part-a/~chapter-110/~article-ii/~division-2.md previous: https://georgiacommons.org/counties/charlton/code/110-52.md next: https://georgiacommons.org/counties/charlton/code/110-59.md index: https://georgiacommons.org/counties/charlton.md branch: code edition: As published by Municode, current through 2023-05-18 edition_date_kind: current_through source_publisher: Municode version_id: local-code:charlton-county/code/110-53@2023-05-18-0b7f977178 --- # Charlton County Code of Ordinances, Sec. 110-53. Effective > As published by Municode, current through 2023-05-18 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Part A - GENERAL CODE OF ORDINANCES / Chapter 110 - BUILDINGS AND BUILDING REGULATIONS / Article II - PLUMBING / Division 2 - FLOW RESTRICTIONS ON FIXTURES The requirements of section 110-58 shall apply to any residential construction initiated after July 1, b. Is a single flush water closet, including gravity, pressure assisted and electro-hydraulic tank types, that meets the following standards: 1. The average flush volume may not exceed 1.28 gallons; 2 The toilet must meet the performance, testing, and labeling requirements prescribed by the American Society of Mechanical Engineers Standard A112.192/CSA B45.1 or A112.19.14; and 3. The toilet must be listed to the WaterSense™ Tank-Type High Efficiency Toilet Specification; (2) A shower head that allows a flow of no more than an average of 2.5 gallons of water per minute at 60 pounds per square inch of pressure; (3) A urinal and associated flush valve that: a. Uses no more than 0.5 gallons of water per flush; b. Meets the performance, testing and labeling requirements prescribed by the American Society of Mechanical Engineers Standard A112.19.2/CSA B45.1; c. For flushing urinals, meets all WaterSense™ Specifications for flushing urinals; and d. Where nonwater urinals are employed, complies with American Society of Mechanical Engineers Standard A112.19.3/CSA B45.4 or American Society of Mechanical Engineers Standard A112.19.19/CSA B45.4. Nonwater urinals shall be cleaned and maintained in accordance with the manufacturer's instructions after installation. Where nonwater urinals are installed they shall have a water distribution line roughed-in to the urinal location at a minimum height of 56 inches (1,422 millimeters) to allow for the installation of an approved backflow prevention device in the event of a retrofit. Such water distribution lines shall be installed with shut-off valves located as close as possible to the distributing main to prevent the creation of dead ends. Where nonwater urinals are installed, a minimum of one water supplied fixture rated at a minimum of one water supply fixture unit shall be installed upstream on the same drain line to facilitate drain line flow and rinsing; (4) A lavatory faucet or lavatory replacement aerator that allows a flow of no more than 1.5 gallons of water per minute at a pressure of 60 pounds per square inch in accordance with American Society of Mechanical Engineers Standard A112.18.1/CSA B.125.1 and listed to the WaterSense™ High-Efficiency Lavatory Faucet Specification; and (5) A kitchen faucet or kitchen replacement aerator that allows a flow of no more than 2.0 gallons of water per minute. ## History (Code 1999, § 5-42)