--- title: Charlton County Code of Ordinances, Sec. 160-36. Utilities collection: local-codes id: local-code:charlton-county/code/160-36 cite_as: Charlton County, Ga., Code of Ordinances § 160-36 canonical_url: https://georgiacommons.org/counties/charlton/code/160-36 md_url: https://georgiacommons.org/counties/charlton/code/160-36.md text_url: https://georgiacommons.org/counties/charlton/code/160-36/text source_url: https://library.municode.com/ga/charlton_county/codes/code_of_ordinances date: 2023-05-18 status: active jurisdiction: county:charlton jurisdiction_name: Charlton County county_fips: "13049" corpus_version: local-codes-charlton-county-4529f7e63a90 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/charlton/code/~part-ii/~part-a/~chapter-160/~article-ii.md previous: https://georgiacommons.org/counties/charlton/code/160-35.md next: https://georgiacommons.org/counties/charlton/code/160-37.md index: https://georgiacommons.org/counties/charlton.md branch: code edition: As published by Municode, current through 2023-05-18 edition_date_kind: current_through source_publisher: Municode version_id: local-code:charlton-county/code/160-36@2023-05-18-b3f1f3ab2f --- # Charlton County Code of Ordinances, Sec. 160-36. Utilities > As published by Municode, current through 2023-05-18 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Part A - GENERAL CODE OF ORDINANCES / Chapter 160 - SUBDIVISION REGULATIONS / Article II - DESIGN STANDARDS All utilities shall conform to the following requirements: (1) Private or individual water and sewer systems. Where either public water or public sewers, or both, are determined by the county commission not available to a subdivision, and a subdivider shall decide to establish a private water supply system and a private sewer system or allow individual systems then plans and specifications for such private or individual water and sewage systems shall be approved by the environmental protection division of the state department of natural resources and shall be so installed as to simplify later connection to public utility systems, where determined to be appropriate by the county commission or its designee. (2) Fire hydrants. Fire hydrants shall be required for all subdivisions to be served by a public water system, and when determined by the county fire chief for subdivisions served by private water systems. As required by the national fire prevention code and as adopted by the county board of commissioners, fire hydrants shall be located no more than 500 feet apart and within 500 feet of any structure and shall be on an eight-inch water line main. To eliminate future street openings, all underground utilities for fire hydrants, together with the fire hydrants themselves and all other supply improvements shall be installed and approved by the county fire chief before any final paving of a street shown on the subdivision plat. (3) Tracer wire. Tracer wire or tape, as approved by the county engineer, shall be placed with all buried nonmetallic utility lines (trunk lines and lateral service lines) and underground irrigation systems. (4) Street lighting. Street lights shall be required at new street entrances on streets designated or classified as arterial streets where the ADT generated by the new street is 200 or more. Street lights shall also be required at new street entrances on streets designated or classified as collector streets where the ADT generated by the new street is 900 or more. Street lights shall be provided by the developer and installed by the developer in accordance with design and specification standards approved by the county traffic safety engineer. Street lights shall be in place prior to final inspection and approval by the county engineer for all improvements. ## History (Ord. of 4-06-2006(01), § 606)