Any dwelling or building which has any or all of the following defects shall be deemed unfit for human habitation: (1) Any dwelling or building whose walls or vertical members list, lean or buckle to such an extent that a plumb line suspended from the top edge of such member shall fall outside of a distance from the edge equal to one-third of the thickness of such members. (2) Any dwelling or building which has support member or members which have deteriorated to such an extent as to be unable to safely support the applied loads or which have 40 percent damage or deterioration of the nonsupporting, enclosed, or outside walls or covering. (3) Any dwelling or building which has improperly distributed loads upon the floors or roofs or in which the same are overloaded or which have insufficient strength to be reasonably safe for the purpose used. (4) Any dwelling or building which has been damaged by fire, wind, or other causes so as to have become dangerous to life, safety, morals, or the general health and welfare of the occupants. (5) Any dwelling or building which has parts thereof which are so attached that they may fall and injure persons or property. (6) Any dwelling or building which does not have an unobstructed means of egress leading to an open space at ground level, whether such unobstructed egress is at ground level or via steps to ground level. (7) Any dwelling or building which has wiring that is dangerous due to lack of insulation, improper fuses, inadequate grounding, lack of capacity of wires or other dangerous condition. (8) Any dwelling or building which does not have an installed kitchen sink in each dwelling unit properly connected to the hot and cold water supply pipes and the sewer system, and which connection is actively providing a potable water supply. (9) Any dwelling or building which does not have an installed tub or shower and lavatory properly connected to hot and cold water supply pipes and sewer system, and which connection is actively providing a potable water supply. (10) Any dwelling or building which does not have a flush-type water closet located in a room affording privacy and properly connected to the water supply pipes and sewer system, and which connection is actively receiving a water supply so as to allow a toilet to be flushed. (11) Any dwelling or building which does not have installed and operational (i.e., electricity running through the lines) electric lighting facilities installed and functioning in accordance with the minimum requirements of the National Electric Code.