Cherokee County · Code of Ordinances
Part II - CODE OF ORDINANCES / Chapter 26 - ENVIRONMENT / Article II - NOISE
Sec. 26-43. Special events facilities, additional requirements.
About this text
- As published by Municode, current through 2026-01-20
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
(a) Compliance required. In addition to the standards set forth in this article, special events facilities are also required to comply with the provisions of this section, unless otherwise stated. Special event facilities with an active business license at the time of adoption of this article are not required to comply with this section unless violations of section 26-43(d) or (f) are documented by the county marshal. See section 26-43(c)(5).
(b) Zoning requirements. Special events facilities are identified in Table 7.2 - Permitted Uses - of the Zoning Ordinance of Cherokee County and included in the General Agricultural District (AG), requiring a special use permit (SUP), and as a permitted use in other zoning districts including Office/Institutional (OI), Corporate Park District (CP), Neighborhood Commercial (NC), and General Commercial (GC). See also section 7.7-4(b) of the Cherokee County Zoning Ordinance.
(c) Acoustical study required. In the AG Zoning District, prior to applying for a SUP, the owners of special events facilities ("owner") shall complete an acoustical study. In zoning districts where special events facilities are permitted uses, the owner shall complete the acoustical study prior to the issuance of a certificate of occupancy for any structure on the special events facilities site ("premises"). Acoustical study requirements are as follows:
(1) Acoustical study conducted. Under the supervision of the director of planning and zoning ("director"), the "owner" shall engage an acoustical consultant ("consultant") designated by the county to complete an acoustical study of the premises. The acoustical study will examine the effect on properties abutting the premises generally, along with any amplified source of sound, instrument, or sound production device of any type employed on the premises. The acoustical study will determine what, if any, measures the owner can implement to mitigate these effects ("mitigation measures"). The owner shall submit the acoustical study to the county for review and approval of the mitigation measures, prior to implementation. The director will determine as to which mitigation measures shall be required.
If the premises is proposed for construction and/or will include new buildings, regardless of zoning district, the owner will coordinate with the director and the consultant to address acoustics during the design and construction of the premises.
Once construction of the premises is complete, the acoustical study must be completed in accordance with this subsection.
(2) Implementation. The owner will apply for any necessary building permits, as applicable, and implement the mitigation measures identified from the acoustical study and as approved by the director. The chief building official and consultant must verify that the mitigation measures are complete, prior to the issuance of the certificate of occupancy and business license.
(3) Sound level monitoring. The acoustical study will determine if sound level meters are required for installation on the premises to monitor sound pressure levels. If required, the acoustical study will also determine the appropriate locations for the installation of sound level meters. Sound pressure levels will be measured using the A- and C-weighting networks on a sound level meter meeting, at a minimum, the characteristics of a Class 1 or Class 2 sound level meter as specified in the American National Standards Institute specifications for sound level meters (ANSI S1.4-2014/ IEC 61672 (R2019)), or the latest approved revision thereof. The necessary sound level meters will be installed and maintained by the owner. The owner will operate and continuously record readings from the sound level meters during all events hosted on the premises, providing a real-time display of the sound level meters' readings in a conspicuous location, visible to the owner's staff, vendors, and guests.
Systems that implement this functionality will be acceptable to the county upon review and approval by the county.
Waiver. An owner may request a waiver for the acoustical study requirement (section 26-43(c)) from the board of commissioners, if the owner can demonstrate that sounds produced by the proposed special event facility will not be audible at a level equal to or above the background level to nearby and adjacent properties or violate the provisions of this section. The decision to grant or deny a waiver is at the sole discretion of the board of commissioners.
(4) Existing special events facilities. Special event facilities with an active business license at the time of adoption of this article are not required to comply with this section unless violations of section 26-43(d) or (f) are documented by the county marshal. Once a violation(s) is documented, the director shall notify the owner that compliance with section 26-43 is required. The owner shall be granted 90 days to complete the requirements of section 26-43(c) ("compliance timeline"). The director is authorized to grant additional time for compliance, but if after 90 days, in the opinion of the director, the owner has failed to comply with section 26-43(c), the director is authorized to initiate the remedies set forth in section 26-45.
The special events facility may continue to operate during the compliance timeline, unless three or more violations of section 26-43(d) and (f) are documented during this time, in which case, the special events facility must cease operations until compliance with section 26-43 is achieved.
(d) Exterior noise levels. A special event facility shall not employ or operate any amplified source of sound, instrument, or sound production device of any type that exceeds the limits of Table 1 when measured according to (h) and (i), including but not limited to: any loudspeaker; bullhorn, amplifier; public address system; musical instrument; radio; television; or device that plays live or recorded music or other audio programs.
TABLE 1. Allowable Exterior Noise Level* Receiving Property Daytime:
7:00 AM—11:00 PM
Nighttime:
11:00 PM—7:00 AM
dBA dBC dBA dBC Residential use 55 60 40 50 *Leq one-minute
(e) Monitoring. If the special event facility uses sound level meters and detects volumes exceeding the maximum noise levels set forth in Table 1, the owner shall address the excessive noise levels immediately, ensuring the noise level is lowered to compliant levels immediately.
(f) Interior noise levels. The owner shall not employ or operate any amplified source of sound, instrument, or sound production device of any type in such a manner that it raises the total sound level inside a sealed residence above the permissible sound level limits set forth in Table 2 in this section when measured inside a residence. Such measurements shall not be taken in areas, that receive only casual use such as hallways, closets, and bathrooms.
Measurements shall only be taken by the county at the request of the receiving residence property owner ("complainant"), and if the county, after request to do so, fails or declines to take such measurements when requested, the complainant may have its own qualified expert do so and provide the results to the county marshal for consideration, indicating date and time the measurements were taken and demonstrating compliance with the applicable procedures in this subparagraph and subparagraph (h) below.
TABLE 2. Allowable Interior Noise Level* Time Interval Allowable Interior Noise Level 7:00 AM. to 11:00 PM. 55 dBC 11:00 PM to 7:00 AM 45 dBC *Leq one-minute
(g) Background sound. In cases where the measured receiving residential property background dBA or dBC sound levels exceed the levels in Table 1, in no instance shall the sound pressure level from sound sources on the premises exceed the receiving residential property background sound level by more than five dBA or five dBC.
(h) Measurements conducted. Measurements of exterior levels performed by county enforcement staff shall be taken at the receiving residential property boundary, or 25 feet from the closest façade of the occupied residential structure on the property, at whichever point is closest to the occupied residential structure. Sound pressure levels shall be measured using the A- and C-weighting networks on a sound level meter meeting, at a minimum, the characteristics of a Class 1 or Class 2 sound level meter as specified in the American National Standards Institute specifications for sound level meters (ANSI S1.4- 2014/IEC 61672 (R2019)), or the latest approved revision thereof. If access to the residential property for the purpose of performing measurements is not permitted, then no violation can be assessed, and if the county, after request to do so, fails or declines to take such measurements when requested, the complainant may have its own qualified expert do so and provide the results to the county marshal for consideration, indicating date and time the measurements were taken and demonstrating compliance with the applicable procedures in this subparagraph and subsection (i) below.
(i) Measurements procedures. All measurements shall be conducted in accordance with the following procedures:
(1) Only during periods when the sound pressure level from sound sources unrelated to the sound of interest do not dominate the measurement location.
(2) For a period of time sufficient to ensure that the measured sound pressure levels are typical of the sound of interest, but in no event shall the duration of measurement be less than one minute.
(3) Only during periods when wind speeds (including gusts) are no greater than ten mph.
(4) Never under any condition that allows the sound level meter to become wet.
(5) Only after the sound level meter has undergone a field calibration process or method as recommended by the sound level meter manufacturer.
(6) If the level due to sound sources operating on the permitted use cannot be resolved from the background sound level, then there can be no finding of non-compliance.
(7) Compliance for noise levels shall be assessed as Leq one-minute averages over the measurement duration.
History
(Ord. No. 2023-O-013, 10-17-23)
Read this code where it is posted (Municode) The source is the county's code as its publisher or its own website posts it. Check it there for later changes.