--- title: Cherokee County Code of Ordinances, Sec. 28-111. Safeguards and limitations for outdoor burning; permit required collection: local-codes id: local-code:cherokee-county/code/28-111 cite_as: Cherokee County, Ga., Code of Ordinances § 28-111 canonical_url: https://georgiacommons.org/counties/cherokee/code/28-111 md_url: https://georgiacommons.org/counties/cherokee/code/28-111.md text_url: https://georgiacommons.org/counties/cherokee/code/28-111/text source_url: https://library.municode.com/ga/cherokee_county/codes/code_of_ordinances date: 2026-01-20 status: active jurisdiction: county:cherokee jurisdiction_name: Cherokee County county_fips: "13057" corpus_version: local-codes-cherokee-county-89376e9f7115 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/cherokee/code/~part-ii/~chapter-28/~article-v.md previous: https://georgiacommons.org/counties/cherokee/code/28-110.md next: https://georgiacommons.org/counties/cherokee/code/28-112.md index: https://georgiacommons.org/counties/cherokee.md branch: code edition: As published by Municode, current through 2026-01-20 edition_date_kind: current_through source_publisher: Municode version_id: local-code:cherokee-county/code/28-111@2026-01-20-b1c6246fc6 --- # Cherokee County Code of Ordinances, Sec. 28-111. Safeguards and limitations for outdoor burning; permit required > As published by Municode, current through 2026-01-20 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 28 - FIRE PREVENTION AND PROTECTION / Article V - OUTDOOR BURNING No person shall start or maintain any outdoor burning listed in this section without first obtaining a permit issued by Cherokee County Fire Marshal's Office. Permits may be revoked or withheld by the fire marshal for just cause. (a) Bonfire. Burn permit required. A bonfire shall not be located within a minimum of 50 feet of a structure or other combustible material, and shall be a minimum of 100 feet from property lines. The bonfire may not include any brush, leaves, straw or treated lumber. There shall be a 50-foot clear area around the fire area, clear of combustible materials, debris or material that could cause fire to spread. Distances may be increased by the fire marshal depending on the size of the bonfire. Bonfires shall be a maximum of 12 feet in each length, width, and height. The permit will be valid for specified dates and times. (b) Open burning for purposes of land clearing. Burn permit(s) required. The following conditions shall govern open burning for the purposes of land clearing. The company, contractor, and/or landowner in control of the property is responsible for compliance with the requirements of this article and the rules established by GA EPD. Permits may be revoked at any time by the issuing agency or its representing agency if conditions or permit restrictions require such. (1) Open burning for the purpose of land clearing is permitted from October 1 through April 30. (2) An air curtain destructor (ACD), which is constructed, installed, and operating in a manner consistent with good air pollution control practices for minimizing emissions of fly ash and smoke, is required for open burning in a pit for the purposes of land clearing. (3) After the pit/site is prepared, the owner shall schedule an inspection with the Fire Marshal's Office (FMO) and obtain an ACD permit prior to any burning. The permit will be valid for specified dates, with a maximum of 30 days. (4) The location of the ACD pit shall be at least 300 feet from any occupied structure or public road. An ACD used solely for utility clearing or road clearing may be located at a lesser distance upon approval of the fire marshal. (5) No more than one air curtain destructor shall be operated within a ten-acre area at one time, unless there is a minimum of 1,000 feet between any two air curtain destructors. (6) A pit shall be excavated to the following dimensions: 8 feet wide × 12—15 feet deep × 15—30 feet long (the length is dependent upon the length of the ACD manifold). In no case shall the eight-foot width be exceeded. The pit must be excavated so as to have at least three vertical sides in soil capable of maintaining vertical walls 15 feet in depth without failure. Walls shall not be undercut during excavation. If a front-end loader is used for the excavation, the end of the pit used for ingress and egress, as well as the ramp, shall be filled with dirt prior to the start of the burn. Any accumulation of water in the pit shall be removed prior to loading the pit. (7) The manifold shall be placed and properly supported on a berm of soil (one to one and one-half feet high), and the space between the manifold and ground shall be sealed. The manifold shall be positioned to direct the air curtain at an imaginary line 24 and 36 inches below the top of the opposite wall. (8) A "stop guide" or restraint shall be provided at the loading site of the pit to keep the loader from getting too close to the pit during operation. If spalling or "cave off" of the pit walls occurs during operation, a new pit shall be constructed and the existing pit filled with soil. (9) Burning shall occur in the pit, with the pit initially being loaded half full. Only wood waste consisting of trees, logs, large brush and stumps which are relatively free of soil shall be burned. Leaves, sawdust, other densely packed wood wastes, paper, and chemically treated, coated, or impregnated wood shall not be burned. (10) In igniting the wood, up to one-half gallon of fuel oil may be utilized. Tires or other rubber products, plastic, heavy oils, highly volatile solvents such as mineral spirits or gasoline, and asphaltic-based or impregnated materials shall not be used for ignition or to maintain the operation of the air curtain destructor. (11) The fire must be at full intensity prior to intermittent charging. With respect to intermittent charging, the pit shall not be overloaded, so as to not protrude above the air curtain. (12) Ash shall be removed to maintain efficient and proper combustion, and shall not be allowed to build up in the pit to higher than one-third of the pit's depth or to the point that ash impedes combustion and is blown out of the pit, whichever occurs first. (13) The cleaning out of the air curtain destructor pit shall be performed in a manner to prevent fugitive ash and or dust. (14) The air curtain destructor shall not be fired before 10:00 a.m. and the fire must be completely extinguished, using water, covering with dirt or using another acceptable method, at least one hour before sunset. All fires are to be completely extinguished by the specified time unless special conditions exist and prior authorization has been granted. It is the responsibility of the party requesting the permit to notify the issuing agency of the special conditions when the permit is being issued. (15) No open burning for the purposes of land clearing is allowed at night, on weekends, or on holidays. (16) No open burning will be authorized when weather conditions (wind, humidity, temperature, mixing level, overcast, etc.) may jeopardize the safety of life and property as determined by the Fire Marshal's Office based on the daily weather forecast obtained from the state forestry commission or other weather forecasting resource. ## History (Ord. No. 2021-O-013, § 1, 9-7-21)