Cherokee County · Code of Ordinances
Part II - CODE OF ORDINANCES / Chapter 30 - FLOODPLAIN MANAGEMENT AND FLOOD DAMAGE PREVENTION / Article IV - PROVISIONS FOR FLOOD DAMAGE REDUCTION
Sec. 30-58. Building standards for structures and buildings authorized adjacent to the future-conditions floodplain.
About this text
- As published by Municode, current through 2026-01-20
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
(a) Residential buildings. For new construction and substantial improvement of any principal residential building or manufactured home, the elevation of the lowest floor, including basement and access to the building, shall be at least three feet above the base flood elevation or one foot above the future-conditions flood elevation, whichever is higher.
Should solid foundation perimeter walls be used to elevate the structure, openings sufficient to automatically equalize the hydrostatic flood forces on exterior walls shall be provided in accordance with standards of subsection 30-56(e).
(b) Non-residential buildings. For new construction and substantial improvement of any principal non-residential building, the elevation of the lowest floor, including basement and access to the building, shall be at least one foot above the level of the base flood elevation or at least as high as the future-conditions flood elevation, whichever is higher. Should solid foundation perimeter walls be used to elevate the structure, openings sufficient to automatically equalize the hydrostatic flood forces on exterior walls shall be provided in accordance with standards of section 30-56(e). Non-residential buildings may be floodproofed in lieu of elevation. The structure, together with attendant utility and sanitary facilities, must be designed to be watertight to one foot above the base flood elevation, or at least as high as the future-conditions flood elevation, whichever is higher, with walls substantially impermeable to the passage of water and structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A licensed professional engineer or architect shall certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions above, and shall provide such certification to the Cherokee County Engineer using the FEMA Floodproofing Certificate along with the design and operation/maintenance plan.
History
(Ord. No. 2019-O-009, 5-7-19)
Meetings that refer to this section
- Cherokee County Zoning Board of Appeals, August 14, 2025 (Minutes)Refers to this section in the minutes: “Section 30-58”
Read this code where it is posted (Municode) The source is the county's code as its publisher or its own website posts it. Check it there for later changes.