--- title: Cobb County Code of Ordinances, Sec. 54-93. Fire protection sprinkler systems requirements collection: local-codes id: local-code:cobb-county/code/54-93 cite_as: Cobb County, Ga., Code of Ordinances ยง 54-93 canonical_url: https://georgiacommons.org/counties/cobb/code/54-93 md_url: https://georgiacommons.org/counties/cobb/code/54-93.md text_url: https://georgiacommons.org/counties/cobb/code/54-93/text source_url: https://library.municode.com/ga/cobb_county/codes/code_of_ordinances date: 2025-11-20 status: active jurisdiction: county:cobb jurisdiction_name: Cobb County county_fips: "13067" corpus_version: local-codes-cobb-county-24105329f0b5 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/cobb/code/~part-i/~chapter-54/~article-vi.md previous: https://georgiacommons.org/counties/cobb/code/54-92.md next: https://georgiacommons.org/counties/cobb/code/54-94-54-95.md index: https://georgiacommons.org/counties/cobb.md branch: code edition: As published by Municode, current through 2025-11-20 edition_date_kind: current_through source_publisher: Municode version_id: local-code:cobb-county/code/54-93@2025-11-20-8b66ed7d0e --- # Cobb County Code of Ordinances, Sec. 54-93. Fire protection sprinkler systems requirements > As published by Municode, current through 2025-11-20 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part I - OFFICIAL CODE OF COBB COUNTY, GEORGIA / Chapter 54 - FIRE PREVENTION AND PROTECTION / Article VI - FIRE PROTECTION SPRINKLER SYSTEM REQUIREMENTS (a) Except as otherwise provided, supervised fire protection sprinkler systems shall be required for all new hotels and dormitories as described in this subsection and shall be required for existing hotels and dormitories as described in section 54-94. NFPA 13R sprinkler systems shall be allowed in structures up to and including four stories in height. All buildings over four stories in height shall be protected by a NFPA 13 sprinkler system. (b) Except as otherwise provided, supervised fire protection sprinkler systems shall be required for all new apartment buildings two stories or more in height. NFPA 13R sprinkler systems shall be allowed in structures up to and including four stories in height. All buildings over four stories in height shall be protected by a NFPA 13 sprinkler system. All balconies and storage closets accessed from the balcony shall be protected by the fire protection sprinkler system. (c) Exception: Fire protection sprinkler systems are not required for new single story hotels, dormitories and apartment buildings with exit doors leading directly outside from each dwelling unit. (d) All existing hotels, dormitories, and apartment buildings that undergo a substantial renovation, as defined in section 54-54(i). (e) Except as otherwise provided, all new board and care occupancies (personal care homes) with four or more clients and all community living arrangements shall be equipped with an approved sprinkler system. (f) Sections 903.3.1.2.1, 903.4, 903.4.1, 903.4.2, and 903.4.3 of the International Fire Code adopted in section 54-52 are adopted for enforcement on new installations and buildings that undergo substantial renovation or a change in the classification of occupancy. (Ord. of 2-27-07; Ord. of 7-24-07; Amd. of 2-24-09; Amd. of 2-26-13; Amd. of 2-23-16; Amd. of 11-20-25) ## Meetings that refer to this section Found 1: meetings of this government whose minutes or machine transcripts name this section, or an ordinance in its history line, newest first. Found by rule from those records' own words. A reference is a pointer to another record, not a statement that the section applies or was changed. - 2025-11-12: [Cobb County Board of Commissioners regular meeting minutes, November 12, 2025](https://georgiacommons.org/counties/cobb/meetings/cobb-county-board-of-commissioners/2025-11-12.md) (minutes) refers to this section: "Sec. 54- 93"