Sec. 18-112. Restricted residential construction.

About this text

  • As published by Municode, current through 2024-10-07
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

No construction may be initiated within the unincorporated areas of the county for any residential building of any type which employs a:

(1) Gravity tank-type, flushometer-valve, or flushometer-tank toilet that uses more

than an average of 1.6 gallons of water per flush;

(2) Showerhead that allows a flow of more than an average of 2.5 gallons of water

per minute at 60 pounds per square inch of pressure;

(3) Urinal that uses more than an average of

1.0 gallon of water per flush;

(4) Lavatory faucet or lavatory replacement aerator that allows a flow of more than

2.0 gallons of water per minute; or

(5) Kitchen faucet or kitchen replacement aerator that allows a flow of more than

2.5 gallons of water per minute.

History

The history line the source prints at the end of the section.

(Code 2002, § 18-112; Ord. of 9-16-1991, § 2)

Read this code where it is posted (Municode) The source is the county's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:coffee-county/code/18-112@2024-10-07-add521affe

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.