--- title: Columbia County Code of Ordinances, Sec. 42-44. Provisions for flood hazard reduction collection: local-codes id: local-code:columbia-county/code/42-44 cite_as: Columbia County, Ga., Code of Ordinances § 42-44 canonical_url: https://georgiacommons.org/counties/columbia/code/42-44 md_url: https://georgiacommons.org/counties/columbia/code/42-44.md text_url: https://georgiacommons.org/counties/columbia/code/42-44/text source_url: https://library.municode.com/ga/columbia_county/codes/code_of_ordinances date: 2026-02-17 status: active jurisdiction: county:columbia jurisdiction_name: Columbia County county_fips: "13073" corpus_version: local-codes-columbia-county-83d868dbd23f publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/columbia/code/~part-ii/~chapter-42/~article-ii.md previous: https://georgiacommons.org/counties/columbia/code/42-43.md next: https://georgiacommons.org/counties/columbia/code/42-45.md index: https://georgiacommons.org/counties/columbia.md branch: code edition: As published by Municode, current through 2026-02-17 edition_date_kind: current_through source_publisher: Municode version_id: local-code:columbia-county/code/42-44@2026-02-17-b7cd21c0ac --- # Columbia County Code of Ordinances, Sec. 42-44. Provisions for flood hazard reduction > As published by Municode, current through 2026-02-17 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 42 - FLOODS / Article II - FLOOD DAMAGE PREVENTION (a) General standards. In all areas of special flood hazard the following provisions are required: (1) New construction and substantial improvements of existing structures shall be anchored to prevent flotation, collapse or lateral movement of the structure; (2) Manufactured homes shall be anchored to resist flotation, collapse or lateral movement. Anchoring methods may include, but are not limited to, use of over-the-top and/or frame ties to ground anchors. This standard shall be in addition to and consistent with applicable state requirements for resisting wind forces; (3) New construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage; (4) New construction and substantial improvements shall be constructed using methods and practices that minimize flood damage; (5) Electrical, heating, ventilation, plumbing, air conditioning equipment and other service facilities shall be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding; (6) New and replacement water supply systems shall be designed to minimize or eliminate infiltration of floodwaters into the system; (7) New and replacement sanitary sewer systems shall be designed to minimize or eliminate infiltration of floodwaters into the systems and discharge from the systems into floodwaters; (8) On-site waste disposal systems shall be located to avoid impairment to them or contamination from them during flooding; and (9) Any alteration, repair, reconstruction or improvement to a structure, which structure is not in compliance with the provisions of this article, shall not further or extend the non-conformity, and shall meet the requirements of new construction as contained in this article. (b) Specific standards. In all areas of special flood hazard where basic flood elevation data has been provided, as set forth in section 42-35 or subsection 42-43(9), the following standards are required: (1) Residential construction. Where base flood elevation data are available, new construction or substantial improvement of any residential structure shall have the lowest floor, including basement, elevated no lower than three feet above the base flood elevation. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate the unimpeded movement of floodwaters shall be provided in accordance with standards of subsection (3) of this section. (2) Nonresidential construction. New construction or substantial improvement of any commercial, industrial or other nonresidential structure shall have the lowest floor, including basement, elevated no lower than three feet above the level of the base flood elevation. Structures located in A1—30, AE, or AH zones may be floodproofed in lieu of being elevated, provided that all areas of the structure below the required elevation are watertight with walls substantially impermeable to the passage of water, and structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. Furthermore, access to the nonresidential structure shall be constructed at an elevation equal to or above the base flood elevation. A registered professional engineer or architect shall certify that design and methods of construction are in accordance with the accepted standards of practice for meeting the standards of this subsection. Such certification shall be provided to the official as set forth in section 42-42. (3) Elevated buildings. All new construction or substantial improvements of elevated buildings that include fully enclosed areas formed by foundation and other exterior walls below the lowest floor shall be designed as to be an unfinished or flood resistant enclosure and designed to allow for the entry and exit of floodwaters to automatically equalize hydrostatic flood forces on exterior walls. a. Designs for complying with the requirement of this subsection (3) must either be certified by a professional engineer or architect, or meet the following minimum criteria: 1. A minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided; 2. The bottom of all openings shall be no higher than one foot above grade; and 3. Openings may be equipped with screens, louvers, valves or other coverings or devices, provided they permit the automatic flow of floodwaters in both directions. b. All heating and air conditioning equipment and components (including ductwork), all electrical, ventilation, plumbing and other utility connections shall be elevated a minimum of three feet above the base flood elevation. c. So as not to violate the lowest floor criteria of this article, the unfinished or flood resistant enclosure shall only be used for parking of vehicles, limited storage of maintenance equipment used in connection with the premises or entry to the elevated area. d. The interior portion of such enclosed area shall not be partitioned or finished into separate rooms. (4) [Standards where data is available.] Standards for manufactured homes and recreational vehicles where base flood elevation data are available: a. All manufactured homes placed and/or substantially improved on: (1) individual lots or parcels, (2) in new and/or substantially improved manufactured home parks or subdivisions, (3) in expansions to existing manufactured home parks or subdivisions, or (4) on a site in an existing manufactured home park or subdivision where a manufactured home has incurred substantial damage as the result of a flood, must have the lowest floor including basement, elevated no lower than three foot above the base flood elevation. b. Manufactured homes placed and/or substantially improved in an existing manufactured home park or subdivision may be elevated so that either: 1. The lowest floor of the manufactured home is elevated no lower than three foot above the level of the base flood elevation, or 2. The manufactured home chassis is elevated and supported by reinforced piers (or other foundation elements of at least an equivalent strength) of no less than 36 inches in height above grade. c. All manufactured homes must be securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement per subsection (2). d. All recreational vehicles placed on sites must either: 1. Be on the site for fewer than 180 consecutive days; 2. Be fully licensed and ready for highway use, (a recreational vehicle is ready for highway use if it is licensed, on its wheels or jacking system, attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached structures or additions); or 3. The recreational vehicle must meet all the requirements for new construction, including the anchoring and elevation requirements of subsection (1), above. (5) Floodways. Located within the areas of special flood hazard established in section 42-35 are areas designated as floodways. The floodway is an extremely hazardous area due to the velocity of floodwaters which can carry debris, potential projectiles and have erosion potential. The area must remain free of encroachment in order to allow for the discharge of the base flood without increased flood heights. The following provisions shall apply: a. Encroachments are prohibited, including earthen fill, new construction, substantial improvements and other developments unless certification, with supporting hydrologic and hydraulic analyses performed in accordance with standard engineering practice by a registered professional engineer is provided demonstrating that encroachments shall not result in any increase in flood levels or floodway widths during a base flood discharge. b. If the provisions of this subsection are satisfied, all new construction and substantial improvements shall comply with all applicable flood hazard reduction provisions of this section. (c) Building standards for residential singlelot developments on streams without established base flood elevations and/or floodways. For a residential single-lot development not part of a subdivision, located within areas of special flood hazard established in section 42-35 where streams exist but where no base flood data have been provided, or where base flood data have been provided but a floodway has not been delineated, the following provisions shall apply: (1) The administrator shall obtain, review, and reasonably utilize any scientific or historic base flood elevation and floodway data available from a federal, state, or other source, in order to administer the provisions of the ordinance. Only if data are not available from these sources, then the following subsections (2) and (3) shall apply: (2) No encroachments, including fill material or structures, shall be located within a distance of the stream bank equal to two times the width of the stream at the top of the bank, or 25 feet each side from the top of the bank, whichever is greater, unless certification by a registered professional engineer is provided demonstrating that such encroachments shall not result in any increase in flood levels during the occurrence of the base flood discharge. (3) In special flood hazard areas without base flood elevation data, new construction and substantial improvements of existing structures shall have the lowest floor of the lowest enclosed area (including basement) elevated no less than three feet above the highest adjacent grade at the building site. In A-Zone areas where a limited detail study has been completed the lowest floor must be elevated one foot above the estimated base flood elevation. Openings sufficient to facilitate the unimpeded movements of floodwaters shall be provided in accordance with standards of subsection (b)(2). a. All heating and air conditioning equipment and components (including ductwork), all electrical, ventilation, plumbing, and other service facilities shall be elevated no less than three feet above the highest adjacent grade at the building site. (4) The administrator shall review and record the lowest floor elevation level and the record shall become a permanent part of the permit file. (d) Building standards for areas of shallow flooding (AO zones). Areas of special flood hazard established in section 42-35, may include designated AO shallow flooding areas. These areas have base flood depths of one to three feet above ground, with no clearly defined channel. The following provisions apply: (1) All new construction and substantial improvements of residential and nonresidential structures shall have the lowest floor, including basement, elevated to the flood depth number specified on the flood insurance rate map (FIRM), above the highest adjacent grade. If no flood depth number is specified, the lowest floor, including basement, shall be elevated at least three feet above the highest adjacent grade. Openings sufficient to facilitate the unimpeded movements of floodwaters shall be provided in accordance with standards of subsection (b)(2). The administrator shall review the lowest floor elevation level and the record shall become a permanent part of the permit file. (2) New construction or the substantial improvement of a non-residential structure may be floodproofed in lieu of elevation. The structure, together with attendant utility and sanitary facilities, must be designed to be watertight to the specified FIRM flood level plus one foot, above highest adjacent grade, with walls substantially impermeable to the passage of water, and structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A registered professional engineer or architect shall certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions above, and shall provide such certification to the official as set forth above and as required in section 42-43. (3) Drainage paths shall be provided to guide floodwater around and away from any proposed structure. (Ord. No. 14-05, § 1(Exh. A), 2-18-2014; Ord. No. 19-02, § 1(Exh. A), 3-5-2019)