(a) Except as set forth in subsection (b) of this section, a user must collect wastewater samples using flow proportional composite collection techniques. If flow proportional sampling is infeasible, the director may authorize the use of time proportional sampling or a minimum of four grab samples where the user demonstrates that such technique will provide a representative sample of the effluent being discharged. In addition, grab samples may be required to show compliance with instantaneous discharge limits. (b) Samples for oil and grease, temperature, pH, cyanide, phenols, sulfides and volatile organic compounds must be obtained using grab collection techniques. (c) Samples should be taken immediately downstream from pretreatment facilities, if such pretreatment facilities exist, or immediately downstream from the regulated process if no pretreatment facilities exist. If other wastewaters are mixed with the regulated wastewater prior to pretreatment, the user should measure the flows and concentrations necessary to allow use of the combined wastestream formula in order to evaluate compliance with the pretreatment standards as defined in 40 CFR 403.12(b)(5).