--- title: Coweta County Code of Ordinances, 0.019. Lap Yes 0.120 nail collection: local-codes id: local-code:coweta-county/code/0.019 cite_as: Coweta County, Ga., Code of Ordinances § 0.019 canonical_url: https://georgiacommons.org/counties/coweta/code/0.019 md_url: https://georgiacommons.org/counties/coweta/code/0.019.md text_url: https://georgiacommons.org/counties/coweta/code/0.019/text source_url: https://library.municode.com/ga/coweta_county/codes/code_of_ordinances date: 2026-05-19 status: active jurisdiction: county:coweta jurisdiction_name: Coweta County county_fips: "13077" corpus_version: local-codes-coweta-county-8b185fb3c269 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/coweta/code/~part-ii/~chapter-14/~article-ii.md previous: https://georgiacommons.org/counties/coweta/code/0.019r.md next: https://georgiacommons.org/counties/coweta/code/14-31.1.md index: https://georgiacommons.org/counties/coweta.md branch: code edition: As published by Municode, current through 2026-05-19 edition_date_kind: current_through source_publisher: Municode version_id: local-code:coweta-county/code/0.019@2026-05-19-4835244e3d --- # Coweta County Code of Ordinances, 0.019. Lap Yes 0.120 nail > As published by Municode, current through 2026-05-19 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. > Read by OCR from a scanned page: a character, a name, or a number may be misread. Part of: Part II - CODE OF ORDINANCES / Chapter 14 - BUILDINGS AND BUILDING REGULATIONS / Article II - CONSTRUCTION CODES 11 /2 long 0.120 nail 21 /2 long 0.120 nail 21 /2 long 0.120 naily Not allowed Brick veneerz Concrete masonry veneerz 2 Section R703 Yes (note l) See Section R703 and Figure R703.7z Not allowed See Section R703 and Figure R703.7z Hardboardk Panel siding-vertical 7 /16 - Yes Note n Note n Note n Note n Not allowed 6 panel edges, 12 inter. sup.o Hardboardk Lap siding-horizontal 7 /16 Note q Yes Note p Note p Note p Note p Not allowed Same as stud spacing 2 per bearing Steelh 29 ga. Lap Yes 0.113 nail 13 /4 Staple13 /4 0.113 nail 23 /4 Staple21 /2 0.113 nail 21 /2 Staple 21 /4 0.113 naily Stapley Not allowed Same as stud spacing Stone veneer 2 Section R703 Yes (note l) See Section R703 and Figure R703.7z Not allowed See Section R703 and Figure R703.7,z Particleboard panels 3 /8—1 /2 - Yes 6d box nail (2 × 0.099 ) 6d box nail (2 × 0.099 ) 6d box nail (2 × 0.099 ) Box naily Not allowed 6 panel edge, 12 inter. sup. 5 /8 - Yes 6d box nail (2 ×0.099 ) 8d box nail (21 /2 × 0.113 ) 8d box nail (21 /2 × 0.113 ) Box naily Not allowed Plywood panel;sup sup; (exterior grade) 3 /8 - Yes 0.099 nail 2 0.113 nail 21 /2 0.099 nail 2 0.113 naily Not allowed 6 on edges, 12 inter. sup. Vinyl sidingm 0.035 Lap Yes 0.120 nail 11 /2 Staple 13 /4 0.120 nail 2 Staple 21 /2 0.120 nail 2 Staple 21 /2 0.120 naily Stapley Not allowed Same as stud spacing Type of Supports for the Siding Material and Fasteners” © ¢ Wood or Nominal Water- Wood Foam Number Thick- Resistive | Structural |Fiberboard| Gypsum Plastic of Spac-ness Joint Barrier Panel Sheathing | Sheathing | Sheathing | Direct to ing of Siding Material (inches) | Treatment | Required | Sheathing | into Stud | into Stud | into Stud Studs Fasteners Wood rustic, drop ¥s min. Lap Yes Fastener penetration into stud-1" Not Face nail-allowed | in: to Shiplap 1932 aver- Lap Yes 6" widths, age 1 nail per bearing; 8" 7 ? Bevel 716 Lap Yes widths Butt tip a6 Lap Yes and over, 2 nails per bearing Fiber cement panel sid- ae Note s Yes 6d corro-|6d corro-|6d corro-|6d_ corro- Not 6" o.c. on ing” Note x_|sion- sion- sion- sion- allowed |edges, 12" resistant |resistant |resistant resistant 0.¢. on nail nail nail nail’ intermed. studs Fiber cement lap sid- ae Note v Yes 6d corro-|6d corro-|6d corro-|6d_ corro- Not Note w ing” Note x_|sion- sion- sion- sion- allowed resistant |resistant |resistant resistapt nail! nail! nail! nail’ Footnotes to Attachment A For SI: 1 inch = 25.4 mm. a. Based on stud spacing of 16 inches on center where studs are spaced 24 inches, siding shall be applied to sheathing approved for that spacing. Nail is a general description and shall be T-head, modified round head, or round head with smooth or deformed shanks. Staples shall have a minimum crown width of 7/16-inch outside diameter and be manufactured of minimum 16 gauge wire. Nails or staples shall be aluminum, galvanized, or rust-preventative coated and shall be driven into the studs for fiberboard or gypsum backing. Aluminum nails shall be used to attach aluminum siding. Aluminum (0.019 inch) shall be unbacked only when the maximum panel width is 10 inches and the maximum flat area is 8 inches. The tolerance for aluminum siding shall be +0.002 inch of the nominal dimension. All attachments shall be coated with a corrosion-resistant coating. Shall be of approved type. Three-eighths-inch plywood shall not be applied directly to studs spaced more than 16 inches on center when long dimension is parallel to studs. Plywood ¥/2-inch or thinner shall not be applied directly to studs spaced more than 24 inches on center. The stud spacing shall not exceed the panel span rating provided by the manufacturer unless the panels are installed with the face grain perpendicular to the studs or over sheathing approved for that stud spacing. Wood board sidings applied vertically shall be nailed to horizontal nailing strips or blocking set 24 inches on center. Nails shall penetrate 11/2 inches into studs, studs and wood sheathing combined, or blocking. A weather-resistive membrane shall be installed weatherboard fashion under the vertical siding unless the siding boards are lapped or battens are used. k. Hardboard siding shall comply with AHA A135.6. l. For masonry veneer, a weather-resistive sheathing paper is not required over a sheathing that performs as a weather-resistive barrier when a 1-inch air space is provided between the veneer and the sheathing. When the 1-inch space is filled with mortar, a weather-resistive sheathing paper is required over studs or sheathing. m. Vinyl siding shall comply with ASTM D 3679. n. Minimum shank diameter of 0.092 inch, minimum head diameter of 0.225 inch, and nail length must accommodate sheathing and penetrate framing 11 /2 inches. o. When used to resist shear forces, the spacing must be 4 inches at panel edges and 8 inches on interior supports. p. Minimum shank diameter of 0.099 inch, minimum head diameter of 0.240 inch, and nail length must accommodate sheathing and penetrate framing 11 /2 inches. q. Vertical end joints shall occur at studs and shall be covered with a joint cover or shall be caulked. r. Fiber cement siding shall comply with the requirements of ASTM C 1186. s. See Section R703.10.1. t. Minimum 0.102� smooth shank, 0.255� round head. u. Minimum 0.099� smooth shank, 0.250� round head. v. See Section R703.10.2. w. Face nailing: 2 nails at each stud. Concealed nailing: One 11 gauge 11 /2 galv. roofing nail (0.371� head diameter, 0.120� shank) or 6d galv. box nail at each stud. x. See Section R703.2 exceptions. y. Minimum nail length must accommodate sheathing and penetrate framing 11 /2 inches. z. Adhered masonry veneer shall comply with the requirements in Sections 6.1 and 6.3 of ACI 530/ASCE 5/TMS-402. (Code 1985, § 6-6; Ord. of 10-3-95; Ord. of 3-19-96; Ord. of 7-2-96; Ord. of 9-9-97; Ord. of 5-2-00; Ords. of 3-20-01; Ord. of 1-6-04; Ord. of 2-7-06; Ord. of 3-21-06(1); Ord. No. 033-07, 10-11-07; Ord. No. 045-07, 12-6-07; Ord. No. 016-09, 7-7-09; Ord. No. 024-17, 8-8-17; Ord. No. 005-18, 2-27-18)