--- title: Coweta County Code of Ordinances, Sec. 14-33. Amendment to Plumbing Code for water efficiency collection: local-codes id: local-code:coweta-county/code/14-33 cite_as: Coweta County, Ga., Code of Ordinances ยง 14-33 canonical_url: https://georgiacommons.org/counties/coweta/code/14-33 md_url: https://georgiacommons.org/counties/coweta/code/14-33.md text_url: https://georgiacommons.org/counties/coweta/code/14-33/text source_url: https://library.municode.com/ga/coweta_county/codes/code_of_ordinances date: 2026-05-19 status: active jurisdiction: county:coweta jurisdiction_name: Coweta County county_fips: "13077" corpus_version: local-codes-coweta-county-8b185fb3c269 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/coweta/code/~part-ii/~chapter-14/~article-ii.md previous: https://georgiacommons.org/counties/coweta/code/14-32.1.md next: https://georgiacommons.org/counties/coweta/code/604.4.2.1.md index: https://georgiacommons.org/counties/coweta.md branch: code edition: As published by Municode, current through 2026-05-19 edition_date_kind: current_through source_publisher: Municode version_id: local-code:coweta-county/code/14-33@2026-05-19-25dc9d7523 --- # Coweta County Code of Ordinances, Sec. 14-33. Amendment to Plumbing Code for water efficiency > As published by Municode, current through 2026-05-19 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 14 - BUILDINGS AND BUILDING REGULATIONS / Article II - CONSTRUCTION CODES The Georgia State Minimum Standard Plumbing Code has been amended by Coweta County as follows: Chapter 2, Section 202 General Definitions. KITCHEN FAUCET OR KITCHEN FAUCET REPLACEMENT AERATOR. A kitchen faucet or kitchen faucet replacement aerator that allows a flow of no more than 1.8 gallons of water per minute at a pressure of 60 pounds per square inch and conforms to the applicable requirements in ASME A112.18.1/CSA B125.1. LAVATORY FAUCET OR LAVATORY FAUCET REPLACEMENT AERATOR. A lavatory faucet or lavatory faucet replacement aerator that allows a flow of no more than 1.2 gallons per minute at a pressure of 60 pounds per square inch and is listed to the WaterSense High Efficiency Lavatory Faucet Specification. LANDSCAPE IRRIGATION. Flow sensor. An inline device in a landscape irrigation system that produces a repeatable signal proportional to flow rate. Lawn or Landscape Irrigation system. An assembly of component parts that is permanently installed for the controlled distribution of water to irrigate landscapes such as ground cover, trees, shrubs, and other plants. Lawn and Landscape Irrigation System refer to the same system. Master shut-off valve. An automatic valve such as a gate valve, ball valve, or butterfly valve installed as part of the landscape irrigation system capable of being automatically closed by the WaterSense controller. When this valve is closed water will not be supplied to the landscape irrigation system. Pressure regulating device. A device designed to maintain pressure within the landscape irrigation system at the manufacturer's recommended operating pressure and that protects against sudden spikes or drops from the water source. Rain sensor shut-off. An electric device that detects and measures rainfall amounts and overrides the cycle of a landscape irrigation system so as to turn off such system when a predetermined amount of rain has fallen. WaterSense irrigation controller. Is a weather-based or soil moisture-based irrigation controller labeled under the U.S. Environmental Protection Agency's WaterSense program, which includes standalone controllers, add-on devices, and plug-in devices that use current weather data as a basis for scheduling irrigation. WaterSense spray sprinkler bodies. A sprinkler body with integral pressure regulation, generating optimal water spray and coverage labeled under the U.S. Environmental Protection Agency's WaterSense program. SHOWER HEAD. A shower head that allows a flow of no more than the average of 2.0 gallons of water per minute at 80 pounds per square inch of pressure, is listed in the WaterSense Specification for Showerheads, and meets the US Department Definition of Energy definition of showerhead. Chapter 6, Section 604.4 Maximum Flow and Water Consumption. Consistent with the general approach taken in Georgia, these Maximum Flow and Water Consumption requirements and related definitions in Section 604.4 of the plumbing code shall apply to all plumbing systems, including those in one- and two-family dwellings. The maximum water consumption flow rates and quantities for all plumbing fixtures and fixture fittings shall be in accordance with Table 604.4. Exceptions: 1. Blowout design water closets having a water consumption not greater than 3 gallons (13 L) per flushing cycle. 2. Vegetable sprays. 3. Clinical sinks having a water consumption not greater than 4 gallons (17 L) per flushing cycle. 4. Laundry tray sinks and service sinks. 5. Emergency showers and eye wash stations. TABLE 604.4 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS PLUMBING FIXTURE OR FIXTURE FITTING MAXIMUM FLOW RATE OR QUANTITYb Lavatory faucet and replacement aerators, private WaterSense Labeled & 1.2 gpm at 60 psif Lavatory faucet, public (metering) 0.25 gallon per metering cycle Lavatory, public (other than metering) 0.5 gpm at 60 psi Showerheada WaterSense Labeled & 2.0 gpm at 80 psif Kitchen faucet and replacement aerators 1.8 gpm at 60 psif, g PLUMBING FIXTURE OR FIXTURE FITTING MAXIMUM FLOW RATE OR QUANTITYb Urinal 0.5 gallon per flushing cyclef Water closet 1.28 gallons per flushing cyclec, d, e, f For SI: 1 gallon = 3.785 L, 1 gallon per minute = 3.785 L/m, 1 pound per square inch = 6.895 kPa. a. A hand-held shower spray is a shower head. As point of clarification, multiple shower heads may be installed in a single shower enclosure so long as each shower head individually meets the maximum flow rate, the WaterSense requirements, and the US Department of Energy definition of showerhead. However, multiple shower heads are not recommended for water efficiency purposes. b. Consumption tolerances shall be determined from referenced standards. c. For flushometer valves and flushometer tanks, the average flush volume shall not exceed 1.28 gallons. d. For single flush water closets, including gravity, pressure assisted and electrohydraulic tank types, the average flush volume shall not exceed 1.28 gallons. e. For dual flush water closets, the average flush volume of two reduced flushes and one full flush shall not exceed 1.28 gallons. f. See 2014 GA Amendment to Section 301.1.2 'Waiver from requirements of high efficiency plumbing fixtures. g. Kitchen faucets are permitted to temporarily increase the flow above the maximum rate, but not to exceed 2.2 gpm (8.3 L/m) at 60 psi (414 kPa) and must revert to a maximum flow rate of 1.8 gpm (6.8 L/m) at 60 psi (414 kPa) upon valve closure. 604.4.1 Clothes Washers. Residential clothes washers shall be in accordance with the Energy Star program requirements. 604.4.2 Cooling Tower Water Efficiency.