(a) Approval required. Any new construction or redevelopment nonresidential project including more than one freestanding building shall obtain approval of a master sign plan from the director as part of the development review process prior to any signs being erected other than signs permitted during construction. All signs erected or maintained shall conform at all times to the approved master sign plan. The signs approved through the master sign plan are the only signs allowed; any deviations from an approved master sign plan shall be unlawful unless and until a revised master sign plan is approved. (b) Master sign plan application. An application for a master sign plan shall include the following information: (1) Accurate site plan, including location of buildings, parking lots, driveways, and landscaped areas; (2) One set of drawings showing details of a construction and foundation of proposed signs; (3) An accurate indication of the location of each present and proposed future signs of any type, whether requiring a permit or not; (4) An elevation drawing or photo depicting the proposed location of signs on buildings, walls or windows; (5) A scaled drawing showing the size, shape, design, colors, materials, lighting and letter styles of proposed signs; (6) Computation of the maximum total sign area. For buildings with two or more separate businesses, computations shall identify the total maximum area each individual business will be allowed; (7) Plans, including window signage should indicate the areas of the windows to be covered; (8) Master sign plans must be signed by all owners or their authorized agents; (9) Any other maps, drawings, or materials as required by the director to adequately describe the sign proposal. (c) Master sign plan review. An application for a master sign plan shall be reviewed as part of the development review process. (d) Individual sign permits. Individual sign permits are required for all signs contained within an approved master sign plan. (e) Amendments. A master sign plan may be amended by filing a new master sign plan application that conforms with all requirements in this section. (f) Maximum number of signs. (1) One main entrance monument sign. The maximum sign area shall be 100 square feet with a maximum height of eight feet. (2) Secondary entrance signs. Each additional entrance, may have a sign not greater than 60 square feet with a maximum height of eight feet, provided that the secondary entrance sign is at least 500 feet from any other sign. (3) Internal signs. One sign shall be allowed at each intersection of internal streets. The signs shall not exceed ten square feet in area and three feet in height. (4) [Monument signs.] One monument sign is permitted for each separate building which is identified on the approved site plan. a. The maximum sign area of the sign shall be 100 square feet for multiple user lots and 60 square feet for single user lots. Maximum sign areas shall apply to each face separately, but no freestanding sign shall have more than two faces. Where two sign faces are located in a �V� formation, the angle between the two sign faces shall not be greater than 60 degrees. b. The maximum height of the sign is eight feet. (5) Wall signs. Wall signs shall be permitted on the wall facing an internal street subject to the following: a. Wall signs attached flat against the exterior surface of a building may extend not more than 24 inches from the wall. b. The total area for wall signage shall not exceed 25 percent of the total area of the one building facade upon which the signage is placed or 100 square feet, whichever is less. A sign directory is a wall sign. c. Reserved. d. Wall signs shall not extend above the eave line or top of a parapet on the wall to which it is attached. (g) Location of entrance sign. The minimum front setback shall be 15 feet from the edge of the pavement or outside of the right of way, whichever is greater and ten feet from the side and rear lot lines. However, in no case will a sign be allowed to obscure vision at a street or driveway intersection, or railway crossing. For traffic safety, signs shall not be located within the triangular area on a corner lot formed by measuring 20 feet along both street side property lines from their intersection. (h) Significant development exceptions. An exception for the size, height, and number of signs may be granted by the board of commissioners under the master sign plan for significant developments which meet at a minimum all criteria set forth below: (1) The development campus is located on a single tract, parcel, or lot. (2) The tract size is a minimum of 100 acres. (3) The campus is comprised of at least three buildings, at least one of which buildings must be greater than four stories and a minimum of 60 feet in height. (4) The campus development requires 2,000 or more parking spaces. (Ord. No. 038-07, 11-15-07; Ord. No. 011-08, 4-17-08; Ord. No. 026-08, 8-19-08; Ord. No. 020-19, 4-23-19)