--- title: Coweta County Code of Ordinances, Sec. 78-229. Commercial car wash water recycling requirement collection: local-codes id: local-code:coweta-county/code/78-229 cite_as: Coweta County, Ga., Code of Ordinances ยง 78-229 canonical_url: https://georgiacommons.org/counties/coweta/code/78-229 md_url: https://georgiacommons.org/counties/coweta/code/78-229.md text_url: https://georgiacommons.org/counties/coweta/code/78-229/text source_url: https://library.municode.com/ga/coweta_county/codes/code_of_ordinances date: 2026-05-19 status: active jurisdiction: county:coweta jurisdiction_name: Coweta County county_fips: "13077" corpus_version: local-codes-coweta-county-8b185fb3c269 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/coweta/code/~part-ii/~chapter-78/~article-viii.md previous: https://georgiacommons.org/counties/coweta/code/78-228.md next: https://georgiacommons.org/counties/coweta/zoning/whole.md index: https://georgiacommons.org/counties/coweta.md branch: code edition: As published by Municode, current through 2026-05-19 edition_date_kind: current_through source_publisher: Municode version_id: local-code:coweta-county/code/78-229@2026-05-19-d63f9f5593 --- # Coweta County Code of Ordinances, Sec. 78-229. Commercial car wash water recycling requirement > As published by Municode, current through 2026-05-19 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 78 - UTILITIES / Article VIII - COMMERCIAL CAR WASH WATER RECYCLING (a) All new commercial conveyor car washes, permitted and constructed after March 22, 2022, and any car wash remodeled after that date utilizing conveyor car wash technology, shall install operational recycled water systems. A minimum of 50 percent of water utilized by such facilities shall be captured and recycled within the facility. (b) Once installed, all operational recycled water systems shall be maintained in proper working order in accordance with manufacturer's specifications. Semi-annual or more frequent inspections of the system shall be performed by the owner, and records of all inspections shall be maintained at the place of business where they shall be available for inspection by county officials during normal business hours. (Ord. No. 008-22, 3-22-22) APPENDIX A. CROSS-CONNECTION EMERGENCY RESPONSE PLAN All customer inquiries concerning water quality are directed to the department of water distribution. When a complaint is received, it is evaluated over the phone with the customer. If the complaint is determined to be a potential problem, a member of the department of water distribution is dispatched to the area reporting the problem. On arrival in the problem area, the technician will: (A) Make a preliminary judgment of the problem by checking for odor and appearance. (B) If a cross connection problem is suspected, notify the manager of water distribution immediately. If the preliminary report indicates the necessity, follow up procedures may be activated by the manager of water distribution before the samples are returned to the laboratory. (C) Pick up samples and return them for laboratory testing. When samples of the suspected water are returned to the laboratory immediate tests will be made to determine the nature of the pollutant or contaminant. If the limitations of available test equipment prevent identification of the pollutant, the GA EPD will be contacted and a sample dispatched by a water department courier for additional testing. If follow-up procedures are activated, at this point the manager of water distribution and the cross-connection control coordinator are both contacted and notified of the situation. Beginning with the initial inspector's preliminary report, the cross-connection control coordinator shall immediately examine the cross-connection control files to determine potential sources of contamination in the area of concern. The manager of water distribution will begin an evaluation of the problem and activate any or all of the following options he believes proper. (A) Direct the emergency line crews to open hydrants in the problem area and flush the lines. (B) If an identified potentially hazardous cross-connection is in the vicinity of the problem area (as shown on the location map with the hydrants and valves), he may contact the responsible persons (from the cross-connection control files) and with system services personnel make an immediate inspection. If a cross-connection exists, it will be corrected or the water service disconnected. If the customer, whom is responsible for the incident, can be identified, then said customer will bear the cost of correcting the affected systems. (C) Direct the emergency line crews to close valves to isolate the problem area from the total distribution system. (D) Notify customers in the affected areas. (E) Should any testing or discovery during this emergency procedure reveal a health hazard contamination, additional checks to establish the problem area limits will be made, the problem area flushed and treated until proven safe. This situation would also involve using local radio and television media and water department personnel to inform the public and make personal contact with each customer in the problem area. It is the policy of the Coweta County Water Department to provide for personnel to be on duty or on call to execute the above emergency plan at all times. This procedure also requires operating personnel to inform the management of emergency problems. APPENDIX B. TERMINOLOGY FOR BACKFLOW-PREVENTION PROGRAM Authority. The individual, official, board, department or agency established and authorized by county, city and/or other political subdivision created by law to administer and enforce the provisions of the plumbing code, the federal and state safe drinking water acts, and the rules, regulations and policies of Coweta County, in the State of Georgia. Backflow. A reverse flow in a water system from the normal or intended direction. Backflow preventer (BFP). A device designed to prevent reverse flow in a water system. The term should normally be used where backpressure-type backflow is implied. Backflow preventer, double check valve (DCV). A backpressure-type backflow-prevention device designed for continuous or intermittent pressure, including backpressure, where pollutants are involved. Backflow preventer, double detector check (DDC). A backpressure-type backflowprevention device designed to serve also as a detector check on fire protection systems where pollutants are involved. It includes a line-size approved double check valve backflow preventer with a metered bypass, into which has also been incorporated an approved double check valve backflow preventer. Backflow preventer, dual check (DuC). A backpressure-type backflow-prevention device designed especially for containing water systems to residences as the "second line of defense," where pollutants only are involved. Backflow preventer with intermediate atmospheric vent (IAV). A backpressure and back-siphonage-type backflow-prevention device designed to operate under continuous pressure, including backpressure, where low-degree contaminants are involved. Backflow preventer, reduced pressure zone (RPZ). A backpressure and back-siphonagetype backflow-prevention device designed to operate under continuous pressure, including backpressure, where contaminants are involved. Backflow preventer, reduced pressure detector check (RPDC). A backpressure and backsiphonage-type backflow-prevention device designed to serve also as a detector check on fire protection systems where contaminants are involved. It includes a line-size reduced pressure zone backflow preventer with a metered bypass, into which has also been incorporated an approved reduced pressure zone backflow preventer. Backflow-prevention. A program, an ordinance, a code, a policy; designed to discover, to eliminate, to prevent; all unauthorized and uncontrolled backflow and cross-connections. Backflow-prevention by cross-connection control. The installation of a backflow-prevention device at each cross-connection on a premises to protect both the premises and the public water supply main ("the first line of defense"). Backflow-prevention by containment. The installation of a backflow preventer at the service-connection to the premises to protect the public water supply main only ("the second line of defense"). Backpressure. An increase in pressure, in a consumer's water system, or a branch of the system, above that at the service-connection. It is generally caused by pumps, thermal expansion, or reasons other than a reduction or loss of the incoming pressure. Backpressure is generally more evident in a closed water system. Back-siphonage. A reverse flow in a water system caused by a negative pressure in the incoming pipe, when the point of use is at atmospheric pressure. Back-siphonage is generally more evident in an open water system. Back-siphonage preventer. A device designed to prevent reverse flow in a water system. The term should be used only where a negative supply pressure is implied. Certified tester. A person qualified to test and repair backflow-prevention and crossconnection control devices; and who has proved his competency to the Coweta County Water and Sewer Department. Closed water system. One with a checking device installed in the service pipe. A check valve, backflow preventer, or pressure reducing valve would create a closed system. Consumer's water system. All potable water piping, valves, fittings and appurtenances on the premises side of the service-connection. Contaminant. Any substance that, if introduced into the potable water system, could create a health hazard. Cross-connection. A physical connection or arrangement between two otherwise separate piping systems; one of which contains potable water, the other a nonpotable fluid, or water of unknown quality where there could be backflow into the potable system unless it is protected by an appropriate backflow-prevention device. Cross-connection, nonpressure type. A low-inlet installation where a potable water pipe is connected or extended below the overflow rim of a receptacle, or an environment, that contains a nonpotable fluid, and is at atmospheric pressure. Cross-connection, pressure type. An installation where a potable water pipe is connected to a closed vessel, or a piping system, that contains nonpotable fluid, and is above atmospheric pressure. Hazard, degree of. A danger or potential danger to health, due to contaminants entering the potable water system via uncontrolled cross-connections, which can range in severity from mildly toxic to lethal. Inspector. An individual qualified and authorized to make inspections, interpret codes, regulations, and procedures. Open water system. One with no checking device installed in the service pipe. Water from the consumer's system is free to backflow into the main, for whatever reason. Pollutant. Any substance that, if introduced into the potable water system, could be objectionable but could not create a health hazard. Potable water. Any water that, according to recognized standards, is safe for human consumption. Public water supply/system. A water system (including but not limited to supply, treatment, transmission and distribution facilities and appurtenances) operated as a public utility that supplies potable water to the service-connection of the consumer's water system (herein defined, the Coweta County Water and Sewer Department). Representative. A person authorized to represent the superintendent of the Coweta County Water and Sewer Department. Service-connection. The point of delivery of water to a premises: the normal location of the meter. It is the end of the water purveyor's jurisdiction and the beginning of the plumbing officials and the consumer's. Vacuum breaker (VB). A back-siphonage-prevention device that introduces air into the potable water system when the system pressure approaches zero. It is designed for use where the receptacle or environment being served is subject to atmospheric pressure only. Vacuum breaker, atmospheric type (AVB). A back-siphonage-prevention device designed for use under flow conditions only, not to exceed 12 consecutive hours, and where it will be subject to no static pressure, and no backpressure. Vacuum breaker, pressure type (PVB). A back-siphonage-prevention device designed to operate under continuous pressure; static or flowing, but no backpressure. Vacuum breaker, hose type (HVB). A back-siphonage-prevention device designed for hose connections only, but not for continuous pressure, static or flowing. Vacuum relief valve. A device designed to limit the degree of vacuum in a vessel or pipe, but not for cross-connection control.