--- title: Coweta County Code of Ordinances, Sec. 78-93. Implementation and enforcement collection: local-codes id: local-code:coweta-county/code/78-93 cite_as: Coweta County, Ga., Code of Ordinances ยง 78-93 canonical_url: https://georgiacommons.org/counties/coweta/code/78-93 md_url: https://georgiacommons.org/counties/coweta/code/78-93.md text_url: https://georgiacommons.org/counties/coweta/code/78-93/text source_url: https://library.municode.com/ga/coweta_county/codes/code_of_ordinances date: 2026-05-19 status: active jurisdiction: county:coweta jurisdiction_name: Coweta County county_fips: "13077" corpus_version: local-codes-coweta-county-8b185fb3c269 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/coweta/code/~part-ii/~chapter-78/~article-vi.md previous: https://georgiacommons.org/counties/coweta/code/78-92.md next: https://georgiacommons.org/counties/coweta/code/78-94.md index: https://georgiacommons.org/counties/coweta.md branch: code edition: As published by Municode, current through 2026-05-19 edition_date_kind: current_through source_publisher: Municode version_id: local-code:coweta-county/code/78-93@2026-05-19-e1f7c645e5 --- # Coweta County Code of Ordinances, Sec. 78-93. Implementation and enforcement > As published by Municode, current through 2026-05-19 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 78 - UTILITIES / Article VI - BACKFLOW PREVENTION BY CONTAINMENT (1) This program shall be implemented immediately for Backflow Prevention by Containment; in conjunction with the existing Georgia State Plumbing Codes for Backflow Prevention by Cross-Connection Control on all new domestic water, process water, fire protection and irrigation system installations. (2) Implementation of this program shall also commence immediately on existing installations. Priority schedules shall be established and evaluations made by the Coweta County Water and Sewer Department for the consumer's retrofit requirement at the serviceconnection, beginning with those consumers whose premises represent the greatest potential threat to the public potable water supply/system. The Coweta County Water and Sewer Department, however, shall not be responsible for abatement of cross-connections which may exist within a consumer's premises. As a minimum, the evaluation shall consider: the existence of cross-connections; the nature of the materials handled on the property; the probability of a backflow occurring; the degree of piping system complexity; and, the potential for system modification. (3) Certificate of plumbing code compliance (as pertaining to backflow prevention); must be provided by the customer/owner in order to downgrade frommaximum RPZ protection at the service connection. The Coweta County Chief Building Inspector must conduct a compliance inspection report on the total premises to insure that proper backflow prevention is in place as required by the Coweta County Plumbing Code. The minimum allowable protection at the service connection shall be contingent upon the following annual requirements: a. The Coweta County Chief Building Inspector will complete a compliance inspection report on any plumbing changes made to assure that the total premises has achieved proper backflow protection as required by the Coweta County Plumbing Code. b. A current device test report has been furnished at the time of inspection for each existing backflow preventer. c. Backflow prevention devices that were not in place at the time of compliance inspection have been installed and device test reports submitted by the customer/ owner. d. Submit certificate of compliance and device test reports annually to the coweta county water department backflow prevention section. (4) Request for variance; from the requirements to install an approved double detector check (DDC) backflow preventer on a fire service-connection, designated for fire protection use only, may be granted for an existing service connection only, and is contingent upon the following: a. The service connection has an existing operable single detector check valve, and system has less than 1,000 feet of yard piping with two or less fire hydrants. b. All intervening connections serving pumps, hose cabinets, standpipe and/or sprinkler systems are protected by an approved backflow preventer as required by the type hazard(s) involved. c. Device test reports must be submitted annually to the Coweta County Water Department, backflow-prevention section for backflow-prevention device(s) existing and for any future addition(s). (5) Enforcement of this program shall be administered by the Coweta County Water and Sewer Department, utilizing its staff in cooperation with those of the plumbing inspection, environmental health, and fire departments of Coweta County as authorized by the Coweta County Board of Commissioners. (6) Penalties. Any person violating any provision of this article shall be liable for a penalty of not more than $1,000.00 per day, by sentence of imprisonment not exceeding 60 days in jail or both fine and jail. Any person found in violation of these provisions shall also pay all costs and expenses involved in the case over and above any fine imposed. Each day shall constitute a separate offense.