--- title: Coweta County Code of Ordinances, Sec. 78-96. Selection of devices collection: local-codes id: local-code:coweta-county/code/78-96 cite_as: Coweta County, Ga., Code of Ordinances ยง 78-96 canonical_url: https://georgiacommons.org/counties/coweta/code/78-96 md_url: https://georgiacommons.org/counties/coweta/code/78-96.md text_url: https://georgiacommons.org/counties/coweta/code/78-96/text source_url: https://library.municode.com/ga/coweta_county/codes/code_of_ordinances date: 2026-05-19 status: active jurisdiction: county:coweta jurisdiction_name: Coweta County county_fips: "13077" corpus_version: local-codes-coweta-county-8b185fb3c269 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/coweta/code/~part-ii/~chapter-78/~article-vi.md previous: https://georgiacommons.org/counties/coweta/code/78-95.md next: https://georgiacommons.org/counties/coweta/code/78-97.md index: https://georgiacommons.org/counties/coweta.md branch: code edition: As published by Municode, current through 2026-05-19 edition_date_kind: current_through source_publisher: Municode version_id: local-code:coweta-county/code/78-96@2026-05-19-a0dbc148e5 --- # Coweta County Code of Ordinances, Sec. 78-96. Selection of devices > As published by Municode, current through 2026-05-19 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 78 - UTILITIES / Article VI - BACKFLOW PREVENTION BY CONTAINMENT (1) Vacuum breakers and backflow preventers shall be selected on basis of the impurities involved and the type cross-connection. The impurities shall be classified as contaminants (hazardous) and pollutants (non-hazardous): the type cross-connection by whether it is non-pressure or pressure as follows: (See Terminology: Appendix B). (a) Cross-connection, non-pressure type. This type of connection, when not protected by a minimum air gap, shall be protected by an appropriate vacuum breaker or an appropriate backflow preventer (BFP). (b) Cross-connection pressure type. This type connection shall be protected by an appropriate BFP only. CAUTION: A pressure vacuum breaker shall not be used alone on a pressure-type cross-connection. NOTE: Because an irrigation system serves an environment that is open to atmosphere, it would not be classified as a pressure-type cross-connection. However, due to the special nature of the installation, minimum protection against backflow shall include a double check valve backflow preventer. If chemicals are injected into the system, minimum protection shall include a reduced pressure zone backflow preventer. Section 1105.7, Georgia State Plumbing Code. As of the effective date of this article, any lawn irrigation shall require a separate tap, meter and backflow preventer purchased from and installed by the Coweta County Water and Sewer Department. No more domestic/lawn irrigation combination systems shall be allowed. Any combination lawn irrigation systems installed after this date shall be considered a penalty and subject to provisions as set forth in section 78-93 of this chapter. (2) Vacuum breakers shall be corrosion resistant. Other backflow-prevention devices, including accessories, components, and fittings in sizes two inches and smaller shall be bronze with threaded connections. Sizes 21 /2 inches and larger shall be bronze, or fused epoxy-coated iron inside and out, or galvanized iron, with flanged connections. (3) Each device shall have a brass identification tag, securely attached with corrosionresistant mechanical fasteners, and include the manufacturer's name, serial number, and maximum working pressure and temperature. ## History (Ord. of 11-15-05)