(a) Any decibel measurement made pursuant to the provisions of this article shall be based on a reference sound pressure of 20 micropascals as measured with a sound level meter using the A-weighted network scale at slow response. (b) The location selected for measuring exterior noise levels shall be at any point on the affected property. Interior noise measurements shall be made within the affected unit. The measurements shall be made at a point at least four feet from the wall, ceiling or floor nearest the noise source with windows in an open position depending on the normal seasonal ventilation requirements. (c) The zoning districts of the county are assigned the following maximum permissible sound levels from stationary sources: Zoning District Time of Day Continuous Sound (dB) Impulsive Sound RR Anytime 90 120 RD, RM, PUD Daytime Nighttime 70 50 110 80 R1, R2, PRD Daytime Nighttime 60 50 80 75 OI, NC Daytime Nighttime 60 65 90 80 GC, HC, I Anytime 70 110 (Res. of 7-9-2002, ยง 8)