Sec. 12-118. Building standards for streams without established base flood elevations and/or floodway (A zones).
About this text
- As published by Municode, current through 2025-12-15
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Buildings and other construction located within the areas of special flood hazard established in section 12-49, where streams exist but no base flood data have been provided (A zones), or where base flood data have been provided but a floodway has not been delineated, the following provisions apply:
(1) When base flood elevation data or floodway data have not been provided in accordance with section 12-49, then the office of building inspection shall obtain, review, and reasonably utilize any scientific or historic base flood elevation and floodway data available from a federal, state, or other source, in order to administer the provisions of this division. Subsections (2) and (3) of this section only apply if data are not available from these sources.
(2) No encroachments, including structures or fill material shall be located within an area equal to the width of the stream or 20 feet, whichever is greater, measured from the top of the stream bank, unless certification by a registered professional engineer is provided demonstrating that such encroachment shall not result in any increase in flood levels during the occurrence of the base flood discharge.
(3) In special flood hazard areas without base flood elevation data, new construction and substantial improvements of existing structures shall have the lowest floor of the lowest enclosed area (including basement) elevated no less than three feet above the highest adjacent grade at the building site. Openings sufficient to facilitate the unimpeded movements of floodwaters shall be provided in accordance with the standards of section 12-116(4). The office of building inspection shall certify the lowest floor elevation level and the record shall become a permanent part of the permit file.
History
(Ord. of 4-14-1998, art. 4, § C)
Read this code where it is posted (Municode) The source is the county's code as its publisher or its own website posts it. Check it there for later changes.