--- title: Douglas County Code of Ordinances, Sec. 10-20. Private fire mains and hydrants collection: local-codes id: local-code:douglas-county/code/10-20 cite_as: Douglas County, Ga., Code of Ordinances ยง 10-20 canonical_url: https://georgiacommons.org/counties/douglas/code/10-20 md_url: https://georgiacommons.org/counties/douglas/code/10-20.md text_url: https://georgiacommons.org/counties/douglas/code/10-20/text source_url: https://library.municode.com/ga/douglas_county/codes/code_of_ordinances date: 2026-03-31 status: active jurisdiction: county:douglas jurisdiction_name: Douglas County county_fips: "13097" corpus_version: local-codes-douglas-county-599dd95b93ed publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/douglas/code/~chapter-10.md previous: https://georgiacommons.org/counties/douglas/code/10-19.md next: https://georgiacommons.org/counties/douglas/code/10-21.md index: https://georgiacommons.org/counties/douglas.md branch: code edition: As published by Municode, current through 2026-03-31 edition_date_kind: current_through source_publisher: Municode version_id: local-code:douglas-county/code/10-20@2026-03-31-cae8b6cc5b --- # Douglas County Code of Ordinances, Sec. 10-20. Private fire mains and hydrants > As published by Municode, current through 2026-03-31 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Chapter 10 - FIRE PROTECTION (a) Water mains on private property for fire protection purposes shall be designed and installed in accordance with local regulations that apply to public mains. Size of mains and water flows shall be adequate for the protection of the property served by said mains. No water pipe smaller than a standard eight (8) inch in diameter shall be used to supply more than one (1) hydrant or one (1) hydrant on dead-end mains over five hundred (500) feet. Hydrants shall meet local governing specifications and be located as required by the Fire Chief or his designee. (b) Prior to installation, two (2) sets of hydraulically engineered detailed plans, bearing a Georgia registered engineers seal or Georgia licensed sprinkler contractor's seal, shall be submitted to the fire department for approval. Before covering any installation, the fire chief or his designee will perform an inspection to assure compliance with local governing authority requirements. (c) Hydrants shall be tested annually to ensure proper functioning. These tests shall include the actual measurement of static and residual pressures, and flow from hydrants. ## History (Ord. of 8-18-09)