Sec. 10-6.1. Residential sprinkler systems.

About this text

  • As published by Municode, current through 2026-03-31
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Automatic fire sprinkler systems shall be installed in all newly constructed multi-family dwellings and duplex dwellings in accordance with the current state adopted edition with amendments

for NFPA 13 or 13R as modified, Standards for the Installation of Sprinkler Systems in Residential Occupancies up to and including three (3) stories in height, regardless of the type of construction or square feet. In addition, automatic fire sprinkler systems shall be installed in all new single-family, regardless of the type of construction, whenever side yard setbacks are less than ten (10) linear feet; said systems shall be installed in accordance with the current state adopted edition with amendments for NFPA 13D as modified, Standards for the Installation of Sprinkler Systems in One- and

Two-Family Dwellings and Manufactured Homes.

"New," for the purpose of this section, shall include any addition to existing buildings, whether vertical or horizontal, or any existing building or

structure which shall be deemed to be new in the event such building or structure is subject to substantial renovation or a fire or other hazard of serious consequence. For the purpose of this sec- tion, the term "substantial renovation" shall mean any construction project involving exits or internalexternal features of such building or structure costing more than or equal to fifty (50) percent of

the building's or structure's gross assessed value according to county tax records at the time of such renovation, repair, remodeling, or replacement thereof.

History

The history line the source prints at the end of the section.

(Ord. of 8-18-09)

Read this code where it is posted (Municode) The source is the county's code as its publisher or its own website posts it. Check it there for later changes.