(a) The manufactured home rental community shall be provided with a sewerage collection system designed to comply with the requirements of the county health department for individual systems or the department of natural resources (DNR) standards for community systems so that each manufactured home stand structure can be serviced. Table 22-3. Septic Tank Size Requirements—Minimum (in Gallons) Individual hookup; 2 or fewer bedrooms 750 Individual hookup; 3 or 4 bedrooms 1,000 Dual hookup; 2 or fewer bedrooms per unit 1,500 (b) Drain field layouts are subject to approval of the county health department.