--- title: Elbert County Code of Ordinances, Sec. 66-63. Development standards for drainage piping and structures collection: local-codes id: local-code:elbert-county/code/66-63 cite_as: Elbert County, Ga., Code of Ordinances ยง 66-63 canonical_url: https://georgiacommons.org/counties/elbert/code/66-63 md_url: https://georgiacommons.org/counties/elbert/code/66-63.md text_url: https://georgiacommons.org/counties/elbert/code/66-63/text source_url: https://library.municode.com/ga/elbert_county/codes/code_of_ordinances date: 2026-11-23 status: active jurisdiction: county:elbert jurisdiction_name: Elbert County county_fips: "13105" corpus_version: local-codes-elbert-county-76292434c225 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/elbert/code/~part-ii/~chapter-34/~article-iii/~division-4.md previous: https://georgiacommons.org/counties/elbert/code/66-62.md next: https://georgiacommons.org/counties/elbert/code/66-64.md index: https://georgiacommons.org/counties/elbert.md branch: code edition: As published by Municode, retrieved 2026-11-23 edition_date_kind: retrieved source_publisher: Municode version_id: local-code:elbert-county/code/66-63@2026-11-23-3d438e6be8 --- # Elbert County Code of Ordinances, Sec. 66-63. Development standards for drainage piping and structures > As published by Municode, retrieved 2026-11-23 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 34 - UTILITIES / Article III - SUBDIVISIONS / Division 4 - GENERAL DESIGN REQUIREMENTS (A) Watercourse and drainage easements. Where a proposed subdivision is traversed by a watercourse, drainageway or stream, appropriate provisions must be made to accommodate stormwater and drainage through and from the proposed subdivision. Such an easement must conform substantially with the lies of the watercourse and be wide enough and of adequate construction to be satisfactory for the purpose. (B) Storm drainage. An adequate drainage system, including necessary open ditches, pipes, culverts, interjectional drains, drop inlets, bridges and the like, must be provided for the proper drainage of all surface water. Cross-drains, drop inlets, bridges and the like, must be provided for the proper drainage of all surface water. Cross-drains must be provided to accommodate all natural water flow and must be extended to 30 feet behind the front yard setback. All such facilities must be shown in plan and profile, including pipe sizes and invert elevations. Outfall ditching must follow property lines on a 20-foot easement to rear property line or natural drainage course. (C) Piping. Storm drainage piping within county rights-of-way (except under residential driveways) shall be reinforced concrete pipe or fully bituminous coated corrugated steel pipe meeting current department of transportation specifications. All piping shall be at least 18 inches in diameter. (D) End structures/headwalls. Headwalls, flared end, vertical wall with wing walls or other end treatments are required on all culverts (except under residential driveways) and at the ends of all piped collection systems. Headwalls are to be pre-cast concrete or stone masonry with reinforced concrete footings or poured-in-place reinforced concrete with reinforced concrete footings. (E) Storm drain structures. All storm drain structures are to be designed to safely pass the Base Flood Elevation, as determined by acceptable design practices. Pipe size and material, the contributing drainage area, runoff co-efficient, times of concentration, maximum water surface elevations or computed peak flow rates with stormwater elevations are to be shown on the construction plans. (F) Roadways. All roadways are to be constructed so as not to encroach on the flood plain limit and must be designed to be not less than three feet above the projected special flood hazard elevation. (G) Storm drain length. Storm drains shall not exceed 500 feet of continuous length between an inlet, manhole or junction box access. In residential subdivisions, outfall piping from catch basins shall, at a minimum, extend from the street to a point 30 feet behind the front building setback line or to the special flood hazard elevation, whichever is less. (H) Culverts. Culverts carrying streams or ditch flow under a street shall be sized so that the base flood elevation headwater height, or shoulder height where there are no curbs and gutters, does not exceed the curb height of 12 inches. Calculations determining the headwater elevation for the base flood elevation and special flood hazard elevation shall be provided by the design engineer. The backwater area computed for the special flood hazard elevation shall be shown and delineated on the final plat. (I) Easements. Drainage easements for improved ditches and pipe construction shall be cleared, opened and stabilized at the time of development to control surface water runoff. Drainage easements shall be provided according to the following minimum requirements and shall conform to county standards: Easement Types Easement Requirements For pipes and conveyance structures at curb 20-foot minimum depth of 0 to 5 feet from surface For pipes and conveyance structures cut 20 feet plus 10 feet added to easement with below 5 feet from surface every 2 feet of cut depth below 5 feet (J) Ditches. Drainage ditches shall have minimum bottom width of two feet and shall have 3:1 side slopes or greater. Erosion and sedimentation considerations shall be covered in the Erosion and Sedimentation Control Plan. (K) Streams and creeks. Where streams or creeks exist within the development, provision shall be made to limit the adverse effects of any increased development. ## History (Ord. of 6-8-2015, att.(66-63))