A building-mounted solar energy system shall be subject to the following regulations: (a) Placement. 1. No solar energy system shall be mounted or affixed to any freestanding wall or fence. 2. Panels and building mounts shall be installed per manufacturer's specifications. 3. In residential zoning districts, a solar energy system for aesthetic reasons shall not be located on the front slope of a pitched roof of a principal residential structure unless no other location for the solar energy equipment is feasible. (b) Height. Building-mounted solar panels or systems shall not exceed 18 inches above the height of any principal building on the site. (c) Permits and code compliance. A building permit shall be required for installation of all building-mounted solar energy systems, except for flush-mounted panels.