(a) Glare and directional control.

(1) Full shielding required. All outdoor lighting fixtures shall be horizontally cutoff or otherwise fully shielded, and shall comply with the terms of this chapter with respect to lighting intensity, glare, and trespass, except as specified otherwise herein.

(2) Diffused-light exception in residential zones. Full shielding to control glare and light trespass is not required in residential zones.

(b) Light trespass. The following light-trespass standard shall apply to all outdoor fixtures not located within a public right-of-way. The standard can be achieved by means of fixture design, metal shielding, lamp type and lumen output, mounting height, location, or natural or constructed barriers on the subject property.

(1) Light-trespass standard. Outdoor-lighting fixtures shall be shielded such that light of one footcandle or greater is not transmitted over the property line of the subject property by more than ten feet in residential zones, by no more than 20 feet in any other zone, or to the wall of the nearest structure on the immediately adjacent property is located at a distance that is less than those listed in this section.

(c) Intensity of illumination. Outdoor sites shall not be illuminated in excess of the standards for lighting levels specified in Table 1, below for specific zones and classes of use or application, measured in footcandle units and based upon the initial lumen-output rating of the fixture lamps. Compliance shall be demonstrated by detailed descriptions, specifications, and photometric plans or studies, as determined by the planning and zoning director.

Table 1. Maximum Allowable Light Standards.

For classes of outdoor use, in footcandles based upon initial lumen-output rating of fixture lamps.

Class of Use or Application Max Footcandles allowed Building entries, retail sales and merchandise display areas 8 fc Parking areas and parking structures 4 fc Nondedicated or private roadways 4 fc Pedestrian walkways 2 fc Structural facades and monuments 6 fc vertical Landscaping features 2 fc vertical Common open space 1 fc Under canopies and drive-through facilities 8 fc

(d) Sign illumination. Except as otherwise specified herein, the following provisions shall apply to all outdoor signs, or other commercial or informational displays.

(1) External illumination of outdoor signs. External sign illumination shall be designed and installed to meet the glare and trespass objectives of this chapter, and that the light source is not visible from any roadway or adjacent property.

(e) Specific exceptions. Specific exemptions to the standards of this Code section shall apply to the following applications, but should be implemented in a manner consistent with the general purposes of this chapter.

(1) Temporary lighting for occasional events, such as outdoor sporting contests, concerts, theater, festivals, carnivals, social gatherings, celebrations, special promotions, or similar occasional events not exceeding a time period of five days and permitted by the county.

(2) Celebratory lighting for seasonal and holiday observances that does not violate the prohibitions of subsection (g), below.

(3) Flags of the United States and the State of Georgia are encouraged to be flown only during daylight hours. But nighttime display of flags is permitted, provided illumination is by no more than two spotlight fixtures not exceeding 3,000 lumens in total. The spotlight can be either a direct burial ground fixture or a pole-mounted fixture, aimed upward and placed as close to the flag as reasonably possible.

Wall-mounted fixtures are permissible, with the same maximum wattage. All fixtures should be mounted such that the light source is not visible from pedestrian pathways.

(4) Decorative, architectural fixtures, such as acorn or lantern styles, are permitted, provided their:

a. Electrical draw does not exceed 75 watts; and

b. Upward-emitted light is refractive only, not direct, and does not exceed two percent of their total light output.

(5) Safety lighting is exempt from the provisions of this chapter, provided it is required for aviation, navigation, tower identification, vehicular-traffic control, emergency response, or any other governmental purpose related to public safety.

(6) Contingency lighting is exempt from the provisions of this chapter, provided it is for public emergencies or construction activities authorized by a government agency, such illumination is temporary, and its duration does not extend beyond the period of the permitted activity.

(f) Flood and spotlight fixtures; directional adjustments.

(1) Vertical angle of illumination. The directional angle of light from applicable fixtures shall be vertically downward, or above the vertical plane at an inclination angle not to exceed 45 degrees.

(2) Horizontal angle of illumination adjacent to public roadways.

a. Applicable fixtures within 100 feet of a public right-of-way shall also conform to either of the following glare-abatement standards:

1. The light-trespass provisions of subsection (b), above; or

2. The fixture's directional axis of light shall be away from the nearest roadway, and aimed on a horizontal plane at an angle from the roadway not less than 45 degrees, or 90 degrees minus the distance (in feet) between the fixture's location and the right-of-way, whichever is greater.

b. In those instances where multiple roadways are impacted by a fixture's glare, the planning and zoning director shall determine the appropriate horizontal angle, shielding, or other remedy which maximizes public safety.

(g) Prohibitions. Except for uses specifically permitted elsewhere herein, the following applications of outdoor lighting shall be prohibited and shall be in violation of this chapter:

(1) Light which is flashing, pulsing, moving, rotating, flickering, chasing, or changing in intensity or color;

(2) Searchlights, beacons, laser-source, or other high-intensity lights;

(3) Bare lamps with illumination ratings exceeding 50 lumens, or 20 lumens if clear glass, that are not housed and protected within a light fixture, and are visible anywhere from beyond the property on which they are located;

(4) Fixtures that may be confused with or construed as a traffic-control or other public-safety device;

(5) Lighting found by reason of attraction, intensity, glare, or trespass to be a public-safety hazard that rises to the level of a public or private nuisance; and

(6) Installation, repair, or lamp replacement of any mercury-vapor light fixture.

History

The history line the source prints at the end of the section.

(Res. No. 25-130, 8-14-2025)

Read this code where it is posted (Municode) The source is the county's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:gilmer-county/code/37-3@2025-12-15-af011823c3

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Gilmer County Code of Ordinances, Sec. 37-3. Outdoor lighting standards | Georgia Commons