  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Only manufactured homes bearing a label certifying that they are constructed in compliance with the National Manufactured Housing Construction and Safety Standards (also known as the HUD Code), manufactured on or after June 15, 1976, may be moved into or relocated in the county.

(1) Sanitary facilities. Every manufactured home shall contain not less than a kitchen sink, lavatory, tub or shower and a water closet, all in working condition when properly connected to an approved water and sewer system. Every plumbing fixture and water and waste pipe shall be in a sanitary working condition free from leaks and obstructions. Septic tank systems must be installed by a bonded septic tank installer.

(2) Hot and cold water supply. Every manufactured home shall have connected to the kitchen sink, lavatory and tub or shower a supply of both cold and hot water.

(3) Water heating system. Every manufactured home shall have a water heating system in a safe working condition.

(4) Heating system. Every manufactured home shall have a heating system in a safe working condition. Unvented fuel-burning heaters shall be prohibited.

(5) Smoke detector. Every manufactured home shall be provided with a state-approved smoke detector installed in accordance with the manufacturer's recommendations and listing.

(6) Windows. Every habitable room, excluding bathrooms, kitchens, and hallways, shall have at least one window which can be opened, facing directly outdoors.

(7) Ventilation. Every habitable room shall have at least one window or skylight which can be opened, or such other device that will ventilate the room.

(8) Electrical.

a. Distribution panels. Distribution panels shall be installed in compliance with the approved listing, complete with required breakers or fuses, with all unused openings covered with blank covers approved and listed for that purpose. Connections shall be checked for tightness. Panels shall be accessible.

b. Electrical system. The electrical system (switches, receptacles, fixtures, etc.) shall be properly installed and wired, and shall be in a working condition. The preowned manufactured home shall be subjected to an electrical continuity test to ensure that all metallic parts are properly bonded.

c. Third party inspection. The retailer may, in lieu of inspecting the electrical and heating systems of a pre-owned manufactured home, request an electrical inspection by a qualified third party. Approval by such a person will be accepted as compliance with those portions of the safety standards established herein which

pertain to electrical systems.

(9) Exterior walls. The exterior of the home shall be free of loose or rotting boards or timbers and any other conditions which might admit rain or dampness to the interior portions of the walls or to the occupied spaces of the manufactured home.

(10) Exterior siding. The exterior siding of the home shall be free of rot and rust, and must be uniform in appearance.

(11) Roofs. Roofs shall be structurally sound and have no obvious defects which might admit rain or cause dampness to the interior portion of the home.

(12) Interior floors, walls, and ceiling. Every floor, interior wall and ceiling shall be kept in sound condition to prevent the admittance of rain or dampness.

History

The history line the source prints at the end of the section.

(Res. of 8-6-2002; Ord. No. 2017-03, § 10-41, 12-5-2017)