--- title: Gordon County Code of Ordinances, Sec. 14-35. Sprinkler requirement for existing buildings and structures collection: local-codes id: local-code:gordon-county/code/14-35 cite_as: Gordon County, Ga., Code of Ordinances ยง 14-35 canonical_url: https://georgiacommons.org/counties/gordon/code/14-35 md_url: https://georgiacommons.org/counties/gordon/code/14-35.md text_url: https://georgiacommons.org/counties/gordon/code/14-35/text source_url: https://library.municode.com/ga/gordon_county/codes/code_of_ordinances date: 2025-08-05 status: active jurisdiction: county:gordon jurisdiction_name: Gordon County county_fips: "13129" corpus_version: local-codes-gordon-county-1c9bbdb767b1 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/gordon/code/~chapter-14/~article-iii.md previous: https://georgiacommons.org/counties/gordon/code/14-34.md next: https://georgiacommons.org/counties/gordon/code/14-36.md index: https://georgiacommons.org/counties/gordon.md branch: code edition: As published by Municode, current through 2025-08-05 edition_date_kind: current_through source_publisher: Municode version_id: local-code:gordon-county/code/14-35@2025-08-05-0c0e9b624b --- # Gordon County Code of Ordinances, Sec. 14-35. Sprinkler requirement for existing buildings and structures > As published by Municode, current through 2025-08-05 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Chapter 14 / Article III - FIRE PREVENTION (a) The purpose of this section is to encourage the continued use or reuse of legally existing buildings and structures. The intent is to permit repairs, renovations, modifications, reconstructions, additions, and change of use or occupancy in existing buildings. (b) Any requirements that are essential for the safety of building occupants and that are not specifically provided for by the life safety code, building code, or fire code, shall be determined by the authority having jurisdiction. (c) The provisions of this chapter shall apply to existing buildings and structures constructed prior to the adoption of this chapter, and shall provide a minimum degree of fire and life safety to persons occupying space which does not comply with current codes. (d) The legal occupancy of any building or structure existing on the date of adoption of this chapter shall be permitted to continue without change, except as otherwise provided, according to the following: (1) No change shall be made in the use or occupancy of any building or structure that would place the building or structure in a different division of the same group of occupancy or in a different group of occupancies, unless it is made to comply with the requirements of the current code for such division or group of occupancy. Any change of use or occupancy classification shall comply with the automatic sprinkler system requirements for new construction. (2) In any building where renovation, modification, or reconstruction exceeds fifty (50) percent of the work area, an automatic fire sprinkler system shall be installed accordance with requirements for new construction and NFPA 13, 13R, or 13D. The requirement shall apply to the highest floor containing a work area and all floors below. (3) Repair, renovation, modification, and reconstruction shall be defined by NFPA 5000. (e) Exceptions. (1) Historic buildings shall be defined as a building or facility deemed to have historical, architectural, or cultural significance by a local, regional, or national jurisdiction, and shall comply with the International Existing Building Code and the International Building Code. (2) Single-family residential dwellings. ## History (Ord. of 2-20-24(1))