The standards related to high efficiency plumbing fixtures shall include without limitation, the following: (1) A water closet or toilet that: a. Is a dual flush water closet that meets the following standards: 1. The average flush volume of two reduced flushes and one full flush may not exceed 1.28 gallons; 2. The toilet meets the performance, testing, and labeling requirements prescribed by the following standards, as applicable: (i) American Society of Mechanical Engineers Standard A112.19.2-2008; and (ii) American Society of Mechanical Engineers Standard A112.19.14-2006, SixLiter Water Closets Equipped with a Dual Flushing Device; and 3. Is listed to the WaterSenseTM Tank-Type High Efficiency Toilet Specification; or b. Is a single flush water closet, including gravity, pressure assisted, and electro-hydraulic tank types, that meets the following standards: 1. The average flush volume may not exceed 1.28 gallons; 2. The toilet must meet the performance, testing, and labeling requirements prescribed by the American Society of Mechanical Engineers Standard A112.192/CSA B45.1 or A112.19.14; and 3. The toilet must be listed to the WaterSenseTM Tank-Type High Efficiency Toilet Specification; (2) A shower head that allows a flow of no more than an average of 2.5 gallons of water per minute at 60 pounds per square inch of pressure; (3) A urinal and associated flush valve that: a. Uses no more than 0.5 gallons of water per flush; b. Meets the performance, testing, and labeling requirements prescribed by the American Society of Mechanical Engineers Standard A112.19.2/CSA B45.1; c. For flushing urinals, meets all WaterSenseTM specifications for flushing urinals; and d. Where non-water urinals are employed, complies with American Society of Mechanical Engineers Standard A112.19.3/CSA B45.4 or American Society of Mechanical Engineers Standard A112.19.19/CSA B45.4. Non-water urinals shall be cleaned and maintained in accordance with the manufacturer's instructions after installation. Where non-water urinals are installed, they shall have a water distribution line roughed-in to the urinal location at a minimum height of 56 inches (1,422 mm) to allow for the installation of an approved backflow prevention device in the event of a retrofit. Such water distribution lines shall be installed with shut-off valves located as close as possible to the distributing main to prevent the creation of dead ends. Where non-water urinals are installed, a minimum of one water supplied fixture rated at a minimum of one water supply fixture unit shall be installed upstream on the same drain line to facilitate drain line flow and rinsing; (4) A lavatory faucet or lavatory replacement aerator that allows a flow of no more than 1.5 gallons of water per minute at a pressure of 60 pounds per square inch in accordance with American Society of Mechanical Engineers Standard A112.18/CSA B.125.1 and listed to theWaterSenseTM High-Efficiency Lavatory Faucet Specification; and (5) A kitchen faucet or kitchen replacement aerator that allows a flow of no more than 2.0 gallons of water per minute.