--- title: Haralson County Code of Ordinances, Sec. 18-83. Water main standards and hydrant spacing collection: local-codes id: local-code:haralson-county/code/18-83 cite_as: Haralson County, Ga., Code of Ordinances ยง 18-83 canonical_url: https://georgiacommons.org/counties/haralson/code/18-83 md_url: https://georgiacommons.org/counties/haralson/code/18-83.md text_url: https://georgiacommons.org/counties/haralson/code/18-83/text source_url: https://library.municode.com/ga/haralson_county/codes/code_of_ordinances date: 2023-06-06 status: active jurisdiction: county:haralson jurisdiction_name: Haralson County county_fips: "13143" corpus_version: local-codes-haralson-county-c793f48c03e6 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/haralson/code/~part-code-of-ordinances/~chapter-18/~article-iii/~division-2.md previous: https://georgiacommons.org/counties/haralson/code/18-63-to-18-82.md next: https://georgiacommons.org/counties/haralson/code/18-84.md index: https://georgiacommons.org/counties/haralson.md branch: code edition: As published by Municode, current through 2023-06-06 edition_date_kind: current_through source_publisher: Municode version_id: local-code:haralson-county/code/18-83@2023-06-06-3de2525642 --- # Haralson County Code of Ordinances, Sec. 18-83. Water main standards and hydrant spacing > As published by Municode, current through 2023-06-06 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part - CODE OF ORDINANCES / Chapter 18 - FIRE PREVENTION AND PROTECTION / Article III - FIRE PROTECTION REGULATIONS / Division 2 - CONSTRUCTION SPECIFICATIONS (a) In single-family approved subdivisions, at least six inch pipe shall be installed, four-inch pipe to be used when it constitutes a good gridiron and then only up to 600 feet in length between interconnecting mains. Fire hydrants shall be spaced not to exceed 600 feet. Two-way hydrants may be used in single-family subdivisions. (b) In multifamily residential subdivisions or multifamily apartment complexes, at least six-inch or larger pipe shall be installed, four-inch pipe to be used when it constitutes a good gridiron and then only up to 600 feet in length between interconnecting mains. Fire hydrants shall be two-way hydrants and shall be spaced not to exceed 500 feet with additional fire hydrants located as necessary to permit all portions of buildings to be reached by hose lays of not more than 600 feet.