--- title: Heard County Code of Ordinances, Sec. 18-69. Specific standards collection: local-codes id: local-code:heard-county/code/18-69 cite_as: Heard County, Ga., Code of Ordinances § 18-69 canonical_url: https://georgiacommons.org/counties/heard/code/18-69 md_url: https://georgiacommons.org/counties/heard/code/18-69.md text_url: https://georgiacommons.org/counties/heard/code/18-69/text source_url: https://library.municode.com/ga/heard_county/codes/code_of_ordinances date: 2024-07-16 status: active jurisdiction: county:heard jurisdiction_name: Heard County county_fips: "13149" corpus_version: local-codes-heard-county-ba3fcb4a8e53 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/heard/code/~part-ii/~chapter-18/~article-iii.md previous: https://georgiacommons.org/counties/heard/code/18-68.md next: https://georgiacommons.org/counties/heard/code/18-70.md index: https://georgiacommons.org/counties/heard.md branch: code edition: As published by Municode, current through 2024-07-16 edition_date_kind: current_through source_publisher: Municode version_id: local-code:heard-county/code/18-69@2024-07-16-e75dcedf54 --- # Heard County Code of Ordinances, Sec. 18-69. Specific standards > As published by Municode, current through 2024-07-16 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 18 - FLOODS / Article III - PROVISIONS FOR FLOOD HAZARD REDUCTION In all areas of special flood hazard where base flood elevation data have been provided, as set forth in section 18-8, 18-47(2) or 18-70, the following provisions are required. (1) Residential construction. New construction or substantial improvement of any residential structure or manufactured home shall have the lowest floor, including basement, elevated no lower than one foot above the base flood elevation. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate the unimpeded movement of floodwaters shall be provided in accordance with standards of subsection (4) of this section. (2) Nonresidential construction. New construction or substantial improvement of any commercial, industrial, or nonresidential structure or manufactured home shall have the lowest floor, including basement, elevated no lower than one foot above the base flood elevation. Structures located in AE or AH zones, may be floodproofed in lieu of elevation, plus one foot, together with attendant utility and sanitary facilities, are designed to be watertight, with walls substantially impermeable to the passage of water, and structural components having the capability or resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A registered professional engineer or architect shall certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions in this subsection, and shall provide such certification to the official as set forth in this subsection and in section 18-47(5). (3) Building standards for streams without established base flood elevations and/or floodways. Located within the areas of special flood hazard established in section 18-8, where streams exist but no base flood data have provided (A-zones from FIRM maps), or where base flood data have been provided without floodway, the following provisions apply: a. When base flood elevation data or floodway data have not been provided in accordance with section 18-8, then the county zoning administrator shall obtain, review, and reasonably utilize any base flood elevation and floodway data available from a federal, state, or other source, in order to administer the provisions of this article. If data are not available from these sources, then subsections (3)b and c of this section shall apply. b. No encroachments, including structures or fill material, shall be located within an area equal to the width of the stream or 20 feet, whichever is greater, measured from the top of the stream bank, unless certification by a registered professional engineer is provided demonstrating that such encroachment shall not result in any increase in flood levels during the occurrence of the base flood discharge. c. In special flood hazard areas without base flood elevation data, new construction and substantial improvements of existing structures shall have the lowest floor of the lowest enclosed area (including basement) elevated no less than three feet above the highest adjacent grade at the building site. The county zoning administrator shall record the lowest flood elevation level and the record shall become a permanent part of the permit file. (4) New construction or substantial improvements. Elevated buildings new construction or substantial improvements of existing structures that include any fully enclosed area located below the base flood elevation formed by foundation and other exterior walls shall be designed so as to be an unfinished or flood-resistant enclosure. The enclosure shall be designed to equalize hydrostatic flood forces on exterior walls by allowing for the automatic entry and exit of floodwaters. a. Designs for complying with this requirement must either be certified by a professional engineer or architect or meet the following minimum criteria: 1. Provide a minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding; 2. The bottom of all openings shall be no higher than one foot above grade; and 3. Openings may be equipped with screens, louvers, valves or other coverings or devices provided they permit the automatic flow of floodwater in both direction. b. So as not to violate the lowest floor criteria of this chapter, the unfinished or flood-resistant enclosure shall only be use for parking of vehicles, limited storage of maintenance equipment used in connection with the premises, or entry to the elevated area; and c. The interior portion of such enclosed area shall not be partitioned or finished into separate rooms. (5) Standards for manufactured homes and recreational vehicles. a. All manufactured homes placed or substantially improved on individual lots or parcels, in new or substantially improved manufactured home park or subdivisions, in expansions to existing manufactured home parks or subdivisions, or on a site in an existing manufactured home has incurred substantial damage as the result of a flood, must have the lowest floor including basement, elevated no lower than one feet above the base flood elevation. b. Manufactured placed or substantially improved in an existing manufactured home park or subdivision may be elevated so that either: 1. The lowest floor of the manufactured home is elevated no lower than one foot above the level of the base flood elevation; or 2. The manufactured home chassis is elevated and supported by reinforced piers (or other foundation elements of at least an equivalent strength) of no less than 36 inches in height above grade. c. All manufactured homes must be securely anchored to the adequately anchored foundation system to resist flotation, collapse and lateral movement, in accordance with section 18-68(5). d. All recreational vehicles placed on sites must either: 1. Be fully licensed and ready for highway use (a recreational vehicle is ready for highway use if it is licensed, on its wheels or jacking system, attached to the site only by quick disconnect-type utilities and security devices, and has no permanently attached structures or additions); or 2. The recreational vehicle must meet all the requirements for new construction, including the anchoring and elevation requirements of subsection (5)a and c of this section. (6) Floodways. Located within areas of special flood hazard established in section 18-8, are areas designated as floodways. A floodway may be an extremely hazardous area due to velocity floodwaters, debris or erosion potential. In addition, the area must remain free of encroachment in order to allow for the discharge of the base flood without increased flood heights. Therefore, the following provisions shall apply: a. Encroachments are prohibited, including earthen fill, new construction, substantial improvements or other development within the regulatory floodway. Development may be permitted however, provided it is demonstrated through hydrologic and hydraulic analyses performed in accordance with standard engineering practice that the encroachment shall not result in any increase in flood levels or floodway widths during a base flood discharge. A registered professional engineer shall provide supporting technical data and certification thereof. b. Only if subsection (6)a of this section is satisfied, then any new construction or substantial improvements shall comply with all other applicable flood hazard reduction provisions of this article. ## History (Ord. No. 50-400, art. 4, § B, 12-12-1995)