--- title: Jasper County Code of Ordinances, Sec. 103-22. Prohibited construction for residential buildings collection: local-codes id: local-code:jasper-county/code/103-22 cite_as: Jasper County, Ga., Code of Ordinances § 103-22 canonical_url: https://georgiacommons.org/counties/jasper/code/103-22 md_url: https://georgiacommons.org/counties/jasper/code/103-22.md text_url: https://georgiacommons.org/counties/jasper/code/103-22/text source_url: https://library.municode.com/ga/jasper_county/codes/code_of_ordinances date: 2026-11-23 status: active jurisdiction: county:jasper jurisdiction_name: Jasper County county_fips: "13159" corpus_version: local-codes-jasper-county-9ae0e531e6c7 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/jasper/code/~part-ii/~part-b/~chapter-103/~article-ii.md previous: https://georgiacommons.org/counties/jasper/code/103-21.md next: https://georgiacommons.org/counties/jasper/code/103-23.md index: https://georgiacommons.org/counties/jasper.md branch: code edition: As published by Municode, retrieved 2026-11-23 edition_date_kind: retrieved source_publisher: Municode version_id: local-code:jasper-county/code/103-22@2026-11-23-b99a949343 --- # Jasper County Code of Ordinances, Sec. 103-22. Prohibited construction for residential buildings > As published by Municode, retrieved 2026-11-23 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Part B - LAND DEVELOPMENT REGULATIONS / Chapter 103 - BUILDINGS AND BUILDING REGULATIONS / Article II - FLOW-RATE RESTRICTIONS ON PLUMBING FIXTURES No construction may be initiated within the county for any residential building of any type which unless the following high-efficiency plumbing fixtures are included: (1) A water closet or toilet that: a. Is a dual flush water closet that meets the following standards: 1. The average flush volume of two reduced flushes and one full flush may not exceed 1.28 gallons; 2. The toilet meets the performance, testing, and labeling requirements prescribed by the following standards, as applicable: (i) American Society of Mechanical Engineers Standard A112.19.2-2008; and (ii) American Society of Mechanical Engineers Standard A112.19.14-2006, Six-Liter Water Closets Equipped with a Dual Flushing Device"; and 3. Is listed to the WaterSense™ Tank-Type High Efficiency Toilet Specification; or b. Is a single flush water closet, including gravity, pressure assisted, and electrohydraulic tank types, that meets the following standards: 1. The average flush volume may not exceed 1.28 gallons; 2. The toilet must meet the performance, testing, and labeling requirements prescribed by the American Society of Mechanical Engineers Standard A112.192/CSA B45.1 or A112.19.14; and 3. The toilet must be listed to the WaterSense™ Tank-Type High Efficiency Toilet Specification; (2) A shower head that allows a flow of no more than an average of 2.5 gallons of water per minute at 60 pounds per square inch of pressure; (3) A urinal and associated flush valve that: a. Uses no more than 0.5 gallons of water per flush; b. Meets the performance, testing, and labeling requirements prescribed by the American Society of Mechanical Engineers Standard A112.19.2/CSA B45.1; c. For flushing urinals, meets all WaterSense™ specifications for flushing urinals; and d. Where non-water urinals are employed, complies with American Society of Mechanical Engineers Standard A112.19.3/CSA B45.4 or American Society of Mechanical Engineers Standard A112.19.19/CSA B45.4. Non-water urinals shall be cleaned and maintained in accordance with the manufacturer's instructions after installation. Where non-water urinals are installed they shall have a water distribution line roughed in to the urinal location at a minimum height of 56 inches (1,422 mm) to allow for the installation of an approved backflow prevention device in the event of a retrofit. Such water distribution lines shall be installed with shut-off valves located as close as possible to the distributing main to prevent the creation of dead ends. Where non-water urinals are installed, a minimum of one water supplied fixture rated at a minimum of one water supply fixture unit shall be installed upstream on the same drain line to facilitate drain line flow and rinsing; (4) A lavatory faucet or lavatory replacement aerator that allows a flow of no more than 1.5 gallons of water per minute at a pressure of 60 pounds per square inch in accordance with American Society of Mechanical Engineers Standard A112.18.1/CSA B.125.1 and listed to the WaterSense™ High-Efficiency Lavatory Faucet Specification; and (5) A kitchen faucet or kitchen replacement aerator that allows a flow of no more than 2.0 gallons of water per minute. ## History (Code 2000, § 14-62; Ord. of 4-1-1991, § 2)