--- title: Jefferson County Code of Ordinances, Sec. 16-98. New construction and substantial improvements collection: local-codes id: local-code:jefferson-county/code/16-98 cite_as: Jefferson County, Ga., Code of Ordinances § 16-98 canonical_url: https://georgiacommons.org/counties/jefferson/code/16-98 md_url: https://georgiacommons.org/counties/jefferson/code/16-98.md text_url: https://georgiacommons.org/counties/jefferson/code/16-98/text source_url: https://library.municode.com/ga/jefferson_county/codes/code_of_ordinances date: 2024-07-09 status: active jurisdiction: county:jefferson jurisdiction_name: Jefferson County county_fips: "13163" corpus_version: local-codes-jefferson-county-29604a8e2e06 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/counties/jefferson/code/~part-ii/~chapter-16/~article-ii/~division-4.md previous: https://georgiacommons.org/counties/jefferson/code/16-97.md next: https://georgiacommons.org/counties/jefferson/code/16-99.md index: https://georgiacommons.org/counties/jefferson.md branch: code edition: As published by Municode, current through 2024-07-09 edition_date_kind: current_through source_publisher: Municode version_id: local-code:jefferson-county/code/16-98@2024-07-09-9400c22ff0 --- # Jefferson County Code of Ordinances, Sec. 16-98. New construction and substantial improvements > As published by Municode, current through 2024-07-09 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 16 - ENVIRONMENT / Article II - FLOOD PREVENTION AND CONTROL / Division 4 - STANDARDS, SPECIFICATIONS AND REGULATIONS For new construction and substantial improvement in all areas of special flood hazard, the following standards shall apply: (1) Where base flood elevation data are available, new construction or substantial improvement of any structure or manufactured home shall have the lowest floor, including basement, elevated no lower than one foot above the base flood elevation. (2) Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate equalization of flood hydrostatic forces on both sides of exterior walls shall be provided in accordance with standards of section 16-93. (3) All heating and air conditioning equipment and components (including ductwork), all electrical, ventilation, plumbing, and other service facilities shall be elevated at or above one foot above the base flood elevation. ## History (Ord. No. 001-10, art. 4, § B(1), 8-10-2010)